Association of device surface and biomaterials with immunologic sensitization after mechanical support

被引:53
作者
George, Isaac [1 ]
Colley, Patrick [1 ]
Russo, Mark J. [1 ]
Martens, Timothy P. [1 ]
Burke, Elizabeth [1 ]
Oz, Mehmet C. [1 ]
Deng, Mario C. [2 ]
Mancini, Donna M. [2 ]
Naka, Yoshifumi [1 ]
机构
[1] Columbia Univ, Coll Phys & Surg, Dept Surg, Div Cardiothorac Surg, New York, NY 10032 USA
[2] Columbia Univ, Coll Phys & Surg, Dept Med, Div Cardiol, New York, NY 10032 USA
关键词
D O I
10.1016/j.jtcvs.2007.11.049
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Biomaterials and textured surfaces in early pulsatile left ventricular assist devices (HeartMate I; Thoratec Corporation, Pleasanton, Calif) may increase immunologic risk through allosensitization. We hypothesized that axial-flow devices without biologic membranes or textured surfaces (HeartMate II; Thoratec; and DeBakey; MicroMed Cardiovascular, Inc, Houston, Tex) would cause less allosensitization than devices with such membranes and surfaces. Methods: HeartMate II and DeBakey (n = 24) and HeartMate I (n = 36) devices were implanted from 1999 to 2006 in patients with severe heart failure cohort-matched for age, etiology, and support duration. Serum samples reacting with more than 10% of the HLA reference panel were considered positive for anti-HLA antibodies. Endomyocardial biopsy samples were collected after transplant. Results: There were no significant cohort differences in age, etiology, sex, blood transfusion, or support duration. Anti-HLA antibodies were not detected at implantation of either HeartMate II and DeBakey or HeartMate I devices; however, significant increases in anti-HLA antibodies were present within 1 and 3 months of support with HeartMate I but not HeartMate II and DeBakey devices. Overall, fewer patients with HeartMate II and DeBakey devices demonstrated positive anti-HLA antibodies during support (8% vs 28%, P = .02), and fewer episodes of acute rejection per patient were seen within the first 9 posttransplant months(0.31 vs 0.69, P = .052). Long-term posttransplant survival was not different between groups. Conclusion: Hemodynamic support with HeartMate II and DeBakey devices produced less allosensitization than did HeartMate I devices. Device selection may improve clinical outcomes for high-risk patients.
引用
收藏
页码:1372 / U310
页数:9
相关论文
共 22 条
[1]  
DEMATTOS AM, 1994, TRANSPLANTATION, V57, P626
[2]   Left ventricular assist system support is associated with persistent inflammation and temporary immunosuppression [J].
Deng, MC ;
Erren, M ;
Tjan, TDT ;
Tamminga, N ;
Werntze, B ;
Zimmermann, P ;
Weyand, M ;
Hammel, D ;
Schmidt, C ;
Scheld, HH .
THORACIC AND CARDIOVASCULAR SURGEON, 1999, 47 :326-331
[3]   The role of IL6 cytokines in acute cardiac allograft rejection [J].
Deng, MC ;
Plenz, G ;
Labarrere, C ;
Marboe, C ;
Baba, HA ;
Erren, M ;
Itescu, S .
TRANSPLANT IMMUNOLOGY, 2002, 9 (2-4) :115-120
[4]   Human leukocyte antigen sensitization in ventricular assist device recipients: A lesser risk with the DeBakey axial pump [J].
Grinda, JM ;
Bricourt, MO ;
Arnrein, C ;
Salvi, S ;
Guillemain, R ;
Francois, A ;
Guibourt, P ;
Deloche, A ;
Fabiani, JN .
ANNALS OF THORACIC SURGERY, 2005, 80 (03) :945-949
[5]   Preformed IgG antibodies against major histocompatibility complex class II antigens are major risk factors for high-grade cellular rejection in recipients of heart transplantation [J].
Itescu, S ;
Tung, TC ;
Burke, EM ;
Weinberg, A ;
Moazami, N ;
Artrip, JH ;
Suciu-Foca, N ;
Rose, EA ;
Oz, MC ;
Michler, RE .
CIRCULATION, 1998, 98 (08) :786-793
[6]   Interactions between the recipient immune system and the left ventricular assist device surface: immunological and clinical implications [J].
Itescu, S ;
John, R .
ANNALS OF THORACIC SURGERY, 2003, 75 (06) :S58-S65
[7]   Immunologic sensitization in recipients of left ventricular assist devices [J].
John, R ;
Lietz, K ;
Schuster, M ;
Naka, J ;
Rao, V ;
Mancini, DM ;
Rose, EA ;
Smith, CR ;
Oz, MC ;
Edwards, NM ;
Itescu, S .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 125 (03) :578-591
[8]   Impact of left venticular assist device (LVAD)-mediated humoral sensitization on post-transplant outcomes [J].
Joyce, DL ;
Southard, RE ;
Torre-Amione, G ;
Noon, GP ;
Land, GA ;
Loebe, M .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2005, 24 (12) :2054-2059
[9]   CARDIAC RETRANSPLANTATION - A VIABLE OPTION [J].
KARWANDE, SV ;
ENSLEY, RD ;
RENLUND, DG ;
GAY, WA ;
RICHENBACHER, WE ;
DOTY, DB ;
HAMMOND, ME ;
MARKS, JD ;
COBANOGLU, A ;
MCKEOWN, PP .
ANNALS OF THORACIC SURGERY, 1992, 54 (05) :840-845
[10]  
Kobashigawa JA, 1996, CIRCULATION, V94, P294