Comparison of cone-beam computed tomography and digital panoramic radiography for detecting peri-implant alveolar bone changes using trabecular micro-structure analysis

被引:9
作者
Magat, Guldane [1 ]
Oncu, Elif [2 ,4 ]
Ozcan, Sevgi [1 ,5 ]
Orhan, Kaan [3 ]
机构
[1] Necmettin Erbakan Univ, Dept Oral & Maxillofacial Radiol, Fac Dent, Yunus Emre Blvd,Baglarbasi St, TR-42090 Konya, Turkey
[2] Necmettin Erbakan Univ, Fac Dent, Dept Periodontol, Konya, Turkey
[3] Ankara Univ, Fac Dent, Dept Oral & Maxillofacial Radiol, Ankara, Turkey
[4] Lokman Hekim Univ, Fac Dent, Dept Pertodontol, Ankara, Turkey
[5] Nigde Omer Halisdemir Univ, Fac Dent, Dept Oral & Lvfaxillofacial Radiol, Nigde, Turkey
关键词
Fractals; Bone density; Panoramic radiography; Cone-beam computed tomography; Dental implants; FRACTAL DIMENSION; QUALITY; PERFORMANCE; ROUGHNESS; DENSITY; SITES;
D O I
10.5125/jkaoms.2022.48.1.41
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: We compared changes in fractal dimension (FD) and grayscale value (GSV) of peri-implant alveolar bone on digital panoramic radiograph (DPR) and cone-beam computed tomography (CBCT) immediately after implant surgery and 12 months postoperative. Materials and Methods: In this retrospective study, 16 patients who received posterior mandibular area dental implants with CBCT scans taken about 2 weeks after implantation and one year after implantation were analyzed. A region of interest was selected for each patient. FDs and GSVs were evaluated immediately after implant surgery and at 12-month follow-up to examine the functional loading of the implants. Results: There were no significant differences between DPR and CBCT measurements of FD values (P>0.05). No significant differences were observed between FD values and GSVs calculated after implant surgery and at the 12-month follow-up (F50.05). GSVs were not correlated with FD values (P>0.05). Conclusion: The DPR and reconstructed panoramic CBCT images exhibit similar image quality for the assessment of FD. There were no changes in FD values or GSVs of the pen-implant trabecular bone structure at the 12-month postoperative evaluation of the functional loading of the implant in comparison to values immediately after implantation. GSVs representing bone mass do not align with FD values that predict bone microstnictural parameters. Therefore, GSVs and Ws should be considered different parameters for assessing bone quality.
引用
收藏
页码:41 / 49
页数:9
相关论文
共 50 条
[1]   A radiographic assessment of progressive loading on bone around single osseointegrated implants in the posterior maxilla [J].
Appleton, RS ;
Nummikoski, PV ;
Pigno, MA ;
Cronin, RJ ;
Chung, KH .
CLINICAL ORAL IMPLANTS RESEARCH, 2005, 16 (02) :161-167
[2]  
Aranyarachkul P, 2005, INT J ORAL MAX IMPL, V20, P416
[3]   Radiographic bone density around immediately loaded oral implants - A case series [J].
Barone, A ;
Covani, U ;
Cornelini, R ;
Gherlone, E .
CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (05) :610-615
[4]  
Bianchi A E, 2005, J Appl Biomater Biomech, V3, P135
[5]  
Bidez M W, 1992, J Oral Implantol, V18, P264
[6]   Fractal dimension on dental radiographs [J].
Bollen, AM ;
Taguchi, A ;
Hujoel, PP ;
Hollender, LG .
DENTOMAXILLOFACIAL RADIOLOGY, 2001, 30 (05) :270-275
[7]  
Branemark P I, 1977, Scand J Plast Reconstr Surg Suppl, V16, P1
[8]  
Brunski JB, 2000, INT J ORAL MAX IMPL, V15, P15
[9]   Peri-implant bone tissue assessment by comparing the outcome of intra-oral radiograph and cone beam computed tomography analyses to the histological standard [J].
Corpas, Livia dos Santos ;
Jacobs, Reinhilde ;
Quirynen, Marc ;
Huang, Yan ;
Naert, Ignace ;
Duyck, Joke .
CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (05) :492-499
[10]   Clinical outcomes of implants following lateral bone augmentation: systematic assessment of available options (barrier membranes, bone grafts, split osteotomy) [J].
Donos, Nikolaos ;
Mardas, Nikolaos ;
Chadha, Vivek .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2008, 35 :173-202