Resistance forces acting on suture needles

被引:79
作者
Frick, TB
Marucci, DD
Cartmill, JA
Martin, CJ
Walsh, WR [1 ]
机构
[1] Univ New S Wales, Prince Wales Hosp, Orthopaed Res Labs, Randwick, NSW 2031, Australia
[2] Univ Sydney, Dept Surg Nepean, Sydney, NSW 2006, Australia
关键词
suture needled; force; penetration; soft tissues; mechanical properties;
D O I
10.1016/S0021-9290(01)00099-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Understanding the resistance forces encountered by a suture needle during tissue penetration is important for the development of robotic surgical devices and virtual reality surgical simulators. Tensile forces applied to skin and tendon during suturing were measured. Fresh sheep achilles tendons were tensioned with a static load 4.9 N, 9.8 N or 19.6 N and sheepskin with 0.98 N, 2.9 N or 4.9 N static load. A straight 2/0 cutting suture needle in series with a load cell on a materials testing machine penetrated the tissue at 90 degrees with a velocity of 1, 5 or 10 mm/s for each tissue tension (n = 5). Continuous load versus displacement data was obtained and penetration load and stiffness were noted. The load versus displacement curve for skin during needle penetration demonstrated two characteristic peaks, corresponding to initial penetration and emergence of needle from the undersurface of the tissue. Increasing the tension within the tissue (skin and tendon) increased the amount of force required to penetrate the tissue with a suture needle (p < 0.05). Needle displacement rate did not affect the resistance to needle penetration (p < 0.05). This study provides a simple model for measuring force-feedback during needle penetration of soft tissues and is a good starting point for future studies of the penetration resistance properties of human tissues. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1335 / 1340
页数:6
相关论文
共 11 条
  • [1] Puncture resistance and tensile strength of skin simulants
    Ankersen, J
    Birkbeck, AE
    Thomson, RD
    Vanezis, P
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H6) : 493 - 501
  • [2] A simulated annealing approach for the one-machine mean tardiness scheduling problem
    BenDaya, M
    AlFawzan, M
    [J]. EUROPEAN JOURNAL OF OPERATIONAL RESEARCH, 1996, 93 (01) : 61 - 67
  • [3] Simulation of resistance forces acting on surgical needles
    Brett, PN
    Parker, TJ
    Harrison, AJ
    Thomas, TA
    Carr, A
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (04) : 335 - 347
  • [4] PAST, PRESENT, AND FUTURE FOR SURGICAL NEEDLES AND NEEDLE HOLDERS
    EDLICH, RF
    THACKER, JG
    MCGREGOR, W
    RODEHEAVER, GT
    [J]. AMERICAN JOURNAL OF SURGERY, 1993, 166 (05) : 522 - 532
  • [5] EDLICH RF, 1990, CLIN PLAST SURG, V17, P583
  • [6] MCCLUNG WL, 1992, OPHTHALMOLOGY, V99, P232
  • [7] Constitutive modelling of brain tissue: Experiment and theory
    Miller, K
    Chinzei, K
    [J]. JOURNAL OF BIOMECHANICS, 1997, 30 (11-12) : 1115 - 1121
  • [8] Mechanical properties of brain tissue in-vivo: experiment and computer simulation
    Miller, K
    Chinzei, K
    Orssengo, G
    Bednarz, P
    [J]. JOURNAL OF BIOMECHANICS, 2000, 33 (11) : 1369 - 1376
  • [9] Dynamics of stab wounds: force required for penetration of various cadaveric human tissues
    O'Callaghan, PT
    Jones, MD
    James, DS
    Leadbeatter, S
    Holt, CA
    Nokes, LDM
    [J]. FORENSIC SCIENCE INTERNATIONAL, 1999, 104 (2-3) : 173 - 178
  • [10] Rosen J, 1999, ST HEAL T, V62, P290