Clinical usefulness of multiple arterial-phase images in gadoxetate disodium-enhanced magnetic resonance imaging: a systematic review and meta-analysis

被引:8
作者
Hong, Sun [1 ,2 ]
Choi, Sang Hyun [1 ,2 ]
Hong, Seung Baek [3 ,4 ]
Kim, So Yeon [1 ,2 ]
Lee, Seung Soo [1 ,2 ]
机构
[1] Univ Ulsan, Dept Radiol, Asan Med Ctr, Coll Med, 88 Olymp Ro 43 Gil, Seoul 05505, South Korea
[2] Univ Ulsan, Res Inst Radiol, Asan Med Ctr, Coll Med, 88 Olymp Ro 43 Gil, Seoul 05505, South Korea
[3] Pusan Natl Univ Hosp, Dept Radiol, Biomed Res Inst, 179 Gudeok Ro, Busan 49241, South Korea
[4] Pusan Natl Univ, Sch Med, 179 Gudeok Ro, Busan 49241, South Korea
基金
新加坡国家研究基金会;
关键词
Liver; Magnetic resonance imaging; Detection; Meta-analysis; LIVER-LESIONS; ACQUISITION; SINGLE;
D O I
10.1007/s00330-022-08620-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives The multiple arterial-phase (AP) technique was introduced for liver MRI, but it is not really known if multiple AP MRI (MA-MRI) improves image quality and lesion detection rate on gadoxetate disodium-enhanced MRI in comparison with single AP MRI (SA-MRI). We aimed to determine the clinical usefulness of MA-MRI in comparison with SA-MRI. Methods Original articles reporting the percentage of adequate AP imaging and the lesion detection rate on gadoxetate disodium-enhanced MA-MRI were identified in PubMed, EMBASE, and Cochrane Library databases. The pooled percentage of adequate AP imaging and lesion detection rate were calculated using random-effects meta-analysis of single proportions. Subgroup analysis was performed to explain causes of study heterogeneity, and publication bias was evaluated using Egger's test. Results Of 772 articles screened, 22 studies in 12 articles were included: 18 studies (ten MA-MRI and eight SA-MRI) suitably defined the percentage of adequate AP imaging and four (three MA-MRI and one SA-MRI) defined the lesion detection rate. MA-MRI had 16.1% higher pooled percentage of adequate AP imaging than SA-MRI (94.8% vs. 78.7%, p < 0.01). MA-MRI additionally detected 33.2% of lesions than SA-MRI (83.2% vs. 50.0%, p = 0.06). Substantial study heterogeneity was found in MA-MRI, and the definition of adequate AP imaging, lesion characteristics, and reference standards were significant factors affecting study heterogeneity (p <= 0.02). Significant publication bias was found in MA-MRI (p < 0.01) but not in SA-MRI studies (p = 0.87). Conclusions Gadoxetate disodium-enhanced MA-MRI may be more clinically useful than SA-MRI, but further study is necessary to validate this finding because of study heterogeneity and publication bias.
引用
收藏
页码:5413 / 5423
页数:11
相关论文
共 27 条
  • [1] Borenstein M, 2009, Introduction to Meta-Analysis
  • [2] Chandarana H, 2015, INVEST RADIOL, V50, P88, DOI 10.1097/RLI.0000000000000105
  • [3] Liver Imaging Reporting and Data System (LI-RADS) Version 2018: Imaging of Hepatocellular Carcinoma in At-Risk Patients
    Chernyak, Victoria
    Fowler, Kathryn J.
    Kamaya, Aya
    Kielar, Ania Z.
    Elsayes, Khaled M.
    Bashir, Mustafa R.
    Kono, Yuko
    Do, Richard K.
    Mitchell, Donald G.
    Singal, Amit G.
    Tang, An
    Sirlin, Claude B.
    [J]. RADIOLOGY, 2018, 289 (03) : 816 - 830
  • [4] Bias in meta-analysis detected by a simple, graphical test
    Egger, M
    Smith, GD
    Schneider, M
    Minder, C
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 1997, 315 (7109): : 629 - 634
  • [5] EASL Clinical Practice Guidelines: Management of hepatocellular carcinoma (vol 69, pg 182, 2018)
    Galle, Peter R.
    Forner, Alejandro
    Llovet, Josep M.
    Mazzaferro, Vincenzo
    Piscaglia, Fabio
    Raoul, Jean-Luc
    Schirmacher, Peter
    Vilgrain, Valerie
    [J]. JOURNAL OF HEPATOLOGY, 2019, 70 (04) : 817 - 817
  • [6] Magnetic Resonance Imaging of Focal Liver Lesions: Approach to Imaging Diagnosis
    Fowler, Kathryn J.
    Brown, Jeffrey J.
    Narra, Vamsi R.
    [J]. HEPATOLOGY, 2011, 54 (06) : 2227 - 2237
  • [7] CAIPIRINHA-Dixon-TWIST (CDT)-VIBE MR imaging of the liver at 3.0T with gadoxetate disodium: a solution for transient arterial-phase respiratory motion-related artifacts?
    Gruber, Leonhard
    Rainer, Vera
    Plaikner, Michaela
    Kremser, Christian
    Jaschke, Werner
    Henninger, Benjamin
    [J]. EUROPEAN RADIOLOGY, 2018, 28 (05) : 2013 - 2021
  • [8] Measuring inconsistency in meta-analyses
    Higgins, JPT
    Thompson, SG
    Deeks, JJ
    Altman, DG
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2003, 327 (7414): : 557 - 560
  • [9] Modified CAIPIRINHA-VIBE without view-sharing on gadoxetic acid-enhanced multi-arterial phase MR imaging for diagnosing hepatocellular carcinoma: comparison with the CAIPIRINHA-Dixon-TWIST-VIBE
    Hong, Seung Baek
    Lee, Nam Kyung
    Kim, Suk
    Seo, Hyeong Il
    Kim, Hyun Sung
    Kim, Dong Uk
    Kim, Tae Un
    Ryu, Hwa Seong
    [J]. EUROPEAN RADIOLOGY, 2019, 29 (07) : 3574 - 3583
  • [10] Improvement of Gadoxetate Arterial Phase Capture With a High Spatio-Temporal Resolution Multiphase Three-Dimensional SPGR-Dixon Sequence
    Hope, Thomas A.
    Saranathan, Manojkumar
    Petkovska, Iva
    Hargreaves, Brian A.
    Herfkens, Robert J.
    Vasanawala, Shreyas S.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (04) : 938 - 945