Application of a multi-turn time-of-flight mass spectrometer, MULTUM II, to organic compounds ionized by matrix-assisted laser desorption/ionization

被引:19
作者
Okumura, D [1 ]
Toyoda, M [1 ]
Ishihara, M [1 ]
Katakuse, I [1 ]
机构
[1] Osaka Univ, Grad Sch Sci, Dept Phys, Toyonaka, Osaka 5600043, Japan
来源
JOURNAL OF MASS SPECTROMETRY | 2004年 / 39卷 / 01期
关键词
multi-turn time-of-flight mass spectrometer; high resolution; liquid matrix; matrix-assisted laser desorption/ionization; organic compounds;
D O I
10.1002/jms.575
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The circuit shape of the ion path, or the multi-turn, provides a solution for achieving unrestricted mass resolution from time-of-flight mass analyzers. The potential of a multi-turn type mass spectrometer, the MULTUM II, with a 1.308 m circuit controlled by four toroidal electric sector fields in biological applications was examined. With matrix-assisted laser desorption/ionization, the ion flight of 18 cycles gave a mass resolution of 10 000 for MH+ of protophorphyrin IX This resolution was correlated with the flight length, and a resolution of 61 000 was achieved for MH+ of angiotensin I after 75 cycles or a 98.75 in total flight. The results demonstrate that the multi-turn mass spectrometer allows not only high resolution but also very high separation of the ions of molecular species from organic compounds. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:86 / 90
页数:5
相关论文
共 17 条
[1]   IMPROVING THE RESOLUTION OF MATRIX-ASSISTED LASER DESORPTION/IONIZATION TIME-OF-FLIGHT MASS-SPECTROMETRY BY EXPLOITING THE CORRELATION BETWEEN ION POSITION AND VELOCITY [J].
COLBY, SM ;
KING, TB ;
REILLY, JP .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (11) :865-868
[2]   LIQUID-MIXTURES FOR MATRIX-ASSISTED LASER-DESORPTION [J].
CORNETT, DS ;
DUNCAN, MA ;
AMSTER, IJ .
ANALYTICAL CHEMISTRY, 1993, 65 (19) :2608-2613
[3]  
Dawson J.H.J., 1989, Rapid Commun. Mass Spectrom, V3, P155, DOI DOI 10.1002/RCM.1290030511
[4]   Perfect space and time focusing ion optics for multiturn time of flight mass spectrometers [J].
Ishihara, M ;
Toyoda, M ;
Matsuo, T .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2000, 197 :179-189
[5]   LASER DESORPTION IONIZATION OF PROTEINS WITH MOLECULAR MASSES EXCEEDING 10000 DALTONS [J].
KARAS, M ;
HILLENKAMP, F .
ANALYTICAL CHEMISTRY, 1988, 60 (20) :2299-2301
[6]  
Kolli VSK, 1996, RAPID COMMUN MASS SP, V10, P923, DOI 10.1002/(SICI)1097-0231(19960610)10:8<923::AID-RCM610>3.3.CO
[7]  
2-5
[8]   Time-of-flight mass spectrometry (concepts, achievements, and prospects) [J].
Mamyrin, BA .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2001, 206 (03) :251-266
[9]   POTENTIAL DISTRIBUTION IN A CYLINDRICAL CONDENSER TERMINATED BY MATSUDA PLATES [J].
MATSUDA, H ;
FUJITA, Y .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1975, 16 (04) :395-404
[10]  
Okumura D., 2003, J MASS SPECTROMETRY, V51, P349, DOI 10.5702/massspec.51.349