Optical Assessment of Soft Contact Lens Edge-Thickness

被引:9
|
作者
Tankam, Patrice [1 ,2 ]
Won, Jungeun [3 ]
Canavesi, Cristina [4 ]
Cox, Ian [2 ,5 ]
Rolland, Jannick P. [1 ,2 ,3 ,4 ]
机构
[1] Univ Rochester, Inst Opt, Rochester, NY 14627 USA
[2] Univ Rochester, Ctr Visual Sci, Rochester, NY 14627 USA
[3] Univ Rochester, Dept Biomed Engn, Rochester, NY 14627 USA
[4] LighTopTech Corp, West Henrietta, NY USA
[5] IGC Consulting, New York, NY USA
基金
美国国家科学基金会;
关键词
soft contact lens; edge-thickness; optical coherence tomography; microscopy; optical metrology; TFOS INTERNATIONAL WORKSHOP; COHERENCE TOMOGRAPHY; IN-VIVO; HIGH-SPEED; DISCOMFORT; MICROSCOPY; EPITHELIUM; QUALITY; VISION; DESIGN;
D O I
10.1097/OPX.0000000000000892
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To assess the edge shape of soft contact lenses using Gabor-Domain Optical Coherence Microscopy (GD-OCM) with a 2-mu m imaging resolution in three dimensions and to generate edge-thickness profiles at different distances from the edge tip of soft contact lenses. Methods. A high-speed custom-designed GD-OCM system was used to produce 3D images of the edge of an experimental soft contact lens (Bausch + Lomb, Rochester, NY) in four different configurations: in air, submerged into water, submerged into saline with contrast agent, and placed onto the cornea of a porcine eyeball. An algorithm to compute the edge-thickness was developed and applied to cross-sectional images. The proposed algorithm includes the accurate detection of the interfaces between the lens and the environment, and the correction of the refraction error. Results. The sharply defined edge tip of a soft contact lens was visualized in 3D. Results showed precise thickness measurement of the contact lens edge profile. Fifty cross-sectional image frames for each configuration were used to test the robustness of the algorithm in evaluating the edge-thickness at any distance from the edge tip. The precision of the measurements was less than 0.2 mu m. Conclusions. The results confirmed the ability of GD-OCM to provide high-definition images of soft contact lens edges. As a nondestructive, precise, and fast metrology tool for soft contact lens measurement, the integration of GD-OCMin the design and manufacturing of contact lenses will be beneficial for further improvement in edge design and quality control. In the clinical perspective, the in vivo evaluation of the lens fitted onto the cornea will advance our understanding of how the edge interacts with the ocular surface. The latter will provide insights into the impact of long-term use of contact lenses on the visual performance.
引用
收藏
页码:987 / 996
页数:10
相关论文
共 50 条
  • [41] The Analysis of Tear Meniscus in Soft Contact Lens Wearers by Spectral Optical Coherence Tomography
    Le, Qihua
    Jiang, Chunhui
    Jiang, Alice C.
    Xu, Jianjiang
    CORNEA, 2009, 28 (08) : 851 - 855
  • [42] Through focus imaging with a non coaxial soft contact lens optical design for presbyopia
    Back, Arthur
    Esfandiarijahromi, Hassan
    Jaisankar, Durgasri
    de Carvalho, Luiz Melk
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [43] OPTICAL PATH LENGTH QUANTIFICATION OF SOFT CONTACT LENS PARAMETER CHANGES DURING DEHYDRATION
    Kollbaum, Pete
    Iskander, D. Robert
    McGiffen, Ryan
    Jansen, Meredith
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [44] The effect of soft contact lens care products on lens modulus
    Young, G.
    Garofalo, R.
    Harmer, O.
    Peters, S.
    CONTACT LENS & ANTERIOR EYE, 2010, 33 (05): : 210 - 214
  • [45] CORNEAL CONTACT-LENS THICKNESS AND MASS
    LOSHIN, DS
    LOWTHER, GE
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1975, 52 (11): : 788 - 788
  • [46] Conjunctival microbiome changes in soft contact lens users and contact lens discomfort patients
    Xiao, Kang
    Song, Hang
    Chen, Zhengyu
    Long, Qin
    BIOMARKERS, 2023, 28 (06) : 531 - 537
  • [47] DETERMINATION OF THE AVERAGE THICKNESS OF A CONTACT-LENS
    DEDONATO, LM
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1981, 58 (10): : 846 - 847
  • [48] Preoperative assessment of corneal and refractive stability in soft contact lens wearing photorefractive candidates
    Firoozabadi, Mehdi Rashighi
    OPTOMETRY AND VISION SCIENCE, 2008, 85 (04) : 279 - 279
  • [49] Pseudokeratoconus in a patient with soft contact lens-induced keratopathy: Assessment with Orbscan I
    Cheng, HC
    Lin, KK
    Chen, YF
    Hsiao, CH
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (04): : 925 - 928
  • [50] Preoperative assessment of corneal and refractive stability in soft contact lens wearing photorefractive candidates
    Ng, Loretta T.
    Lee, Eunice Myung
    Nguyen, Andrew L.
    OPTOMETRY AND VISION SCIENCE, 2007, 84 (05) : 401 - 409