Interference Compensation for Thin Layer Coulometric Ion-Selective Membrane Electrodes by the Double Pulse Technique

被引:16
作者
Grygolowicz-Pawlak, Ewa [1 ]
Numnuam, Apon [1 ,2 ,3 ]
Thavarungkul, Panote [2 ,4 ]
Kanatharana, Proespichaya [2 ,3 ]
Bakker, Eric [1 ]
机构
[1] Univ Geneva, Dept Inorgan Analyt & Appl Chem, CH-1211 Geneva, Switzerland
[2] Prince Songkla Univ, Trace Anal & Biosensor Res Ctr, Hat Yai 90112, Songkhla, Thailand
[3] Prince Songkla Univ, Dept Chem, Hat Yai 90112, Songkhla, Thailand
[4] Prince Songkla Univ, Dept Phys, Hat Yai 90112, Songkhla, Thailand
基金
瑞士国家科学基金会; 澳大利亚研究理事会;
关键词
BOUNDARY POTENTIAL MODEL; SOLUTION INTERFACE; NERNST-PLANCK; BULK OPTODES; SENSORS; CHRONOPOTENTIOMETRY; VOLTAMMETRY; ELECTROLYSIS; COEFFICIENTS; SIMULATION;
D O I
10.1021/ac202273k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ion-selective membranes operated in a thin layer coulometric detection mode have previously been demonstrated to exhibit attractive characteristics in view of realizing sensors without the need for frequent recalibration. In this methodology, the analyte ion is exhaustively removed across an ion-selective membrane by an applied potential, and the resulting current is integrated to yield the coulomb number and hence the amount of analyte originally present in the sample. This exhaustive process, however, places greater demands on the selectivity of the membrane compared to direct potentiometry, since the level of interference will increase as the analyte depletes. We evaluate here a double pulse protocol to reduce the level of interference, in which the sample is electrolyzed once again after the initial coulometric detection pulse. Since the analyte ion is no longer present at significant concentrations during the second pulse, but an interfering ion of high concentration did not appreciably deplete, the second electrolysis step may be used to partially compensate for undesired interference. These processes are here evaluated by numerical simulation for ions of the same charge, demonstrating that the resulting coulomb number may indeed be reduced for systems of limited selectivity. The improvement in operational selectivity relative to uncompensated coulometry is found to be ca. 6-fold. The methodology is successfully demonstrated experimentally with a calcium selective membrane and tetraethylammonium as a model interfering agent, and the observed relative errors after background compensation can be favorably compared to that in direct potentiometry where no sample depletion occurs.
引用
收藏
页码:1327 / 1335
页数:9
相关论文
共 33 条
[1]   Determination of unbiased selectivity coefficients of neutral carrier-based cation-selective electrodes [J].
Bakker, E .
ANALYTICAL CHEMISTRY, 1997, 69 (06) :1061-1069
[2]  
Bakker E, 2004, TALANTA, V63, P3, DOI 10.1016/j.talanta.2003.10.006
[3]   Selectivity of potentiometric ion sensors [J].
Bakker, E ;
Pretsch, E ;
Bühlmann, P .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1127-1133
[4]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[5]   Beyond potentiometry: Robust electrochemical ion sensor concepts in view of remote chemical sensing [J].
Bakker, Eric ;
Bhakthavatsalam, Vishnupriya ;
Gemene, Kebede L. .
TALANTA, 2008, 75 (03) :629-635
[6]   Membrane Response Model for Ion-Selective Electrodes Operated by Controlled-Potential Thin-Layer Coulometry [J].
Bakker, Eric .
ANALYTICAL CHEMISTRY, 2011, 83 (02) :486-493
[7]   Generalized selectivity description for polymeric ion-selective electrodes based on the phase boundary potential model [J].
Bakker, Eric .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2010, 639 (1-2) :1-7
[8]  
BARD AJ, 1966, ANAL CHEM, V38, pR88
[9]   Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors [J].
Buhlmann, P ;
Pretsch, E ;
Bakker, E .
CHEMICAL REVIEWS, 1998, 98 (04) :1593-1687
[10]   Rational design of potentiometric trace level ion sensors.: A Ag+-selective electrode with a 100 ppt detection limit [J].
Ceresa, A ;
Radu, A ;
Peper, S ;
Bakker, E ;
Pretsch, E .
ANALYTICAL CHEMISTRY, 2002, 74 (16) :4027-4036