Intermonitor variability of the RT3 accelerometer during typical physical activities

被引:80
作者
Powell, SM [1 ]
Rowlands, AV [1 ]
机构
[1] Univ Wales, Sch Sport Hlth & Exercise Sci, Bangor LL57 2PX, Gwynedd, Wales
关键词
laboratory; activity assessment; physical activity; accelerometry; motion sensor;
D O I
10.1249/01.MSS.0000113743.68789.36
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: To evaluate the reliability and variability of eight RT3 accelerometers. Methods: The RT3 were subjected to two repeated trials of six activities: rest, walking (4 and 6 km(.)h(-1)), running (8 and 10 km(.)h(-1)), and sit-stand position (20 min). One person performed all trials (female: age 24 yr, height 158.0 cm, mass 48.2 kg). Each activity lasted 12 min. The middle 10 min were taken from each 12-min trial and used as the output measure (cts(.)min(-1)). Data were analyzed for activity (6), monitor (8), and trial (2) effects using four three-way ANOVA: vector magnitude, X (vertical), Y (anterioposterior), and Z (mediolateral) axes. Results: Intermonitor coefficient of variation was <6% during locomotive activities, however, increased to 8-25% during sit-stand. A three-way interaction was found for vector magnitude (F-35,F-315=88945.7, P < 0.001) and Y (F-15,F-115=978435.6, P < 0.001) and Z axes (F-35,F-315=103802.8, P < 0.001). A two-way activity X monitor interaction was found for the X axis (F-35,F-315=1037787.0, P < 0.001). Follow-up tests revealed no differences between trials 1 and 2 for vector magnitude, X and Z axes. One monitor recorded significantly lower activity counts in trial 1 compared with trial 2 along the Y axis. Intermonitor differences were evident at 4, 6, 8, and 10 km(.)h(-1) for the Y and Z axes, and at 6, 8, and 10 km(.)h(-1) for the vector magnitude and X axis. Variability between monitors at each activity increased as intensity increased. Conclusion: Reliability of the RT3 is good; however, intermonitor variability exists. The vertical axis of the RT3 accelerometer showed the least variability and was the most reliable. It is recommended that intermonitor variability and reliability of RT3 on each axis be assessed before use.
引用
收藏
页码:324 / 330
页数:7
相关论文
共 21 条
[1]   Validity and reliability issues in objective monitoring of physical activity [J].
Bassett, DR .
RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 2000, 71 (02) :S30-S36
[2]   The physical activity, fitness and health of children [J].
Boreham, C ;
Riddoch, C .
JOURNAL OF SPORTS SCIENCES, 2001, 19 (12) :915-929
[3]  
BOUCHARD C, 1994, PHYSICAL ACTIVITY FI, P61
[4]  
BOUTEN CV, 1994, MED SCI SPORT EXER, V26, P1516
[5]   Reexamination of validity and reliability of the CSA monitor in walking and running [J].
Brage, S ;
Wedderkopp, N ;
Franks, PW ;
Andersen, LB ;
Froberg, K .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2003, 35 (08) :1447-1454
[6]   Validity of heart rate, pedometry, and accelerometry for predicting the energy cost of children's activities [J].
Eston, RG ;
Rowlands, AV ;
Ingledew, DK .
JOURNAL OF APPLIED PHYSIOLOGY, 1998, 84 (01) :362-371
[7]   Using the computer science and applications (CSA) activity monitor in preschool children [J].
Fairweather, SC ;
Reilly, JJ ;
Grant, S ;
Whittaker, A ;
Paton, JY .
PEDIATRIC EXERCISE SCIENCE, 1999, 11 (04) :413-420
[8]  
HAYMES EM, 1993, MED SCI SPORT EXER, V25, P1365
[9]   Validity of accelerometry for the assessment of moderate intensity physical activity in the field [J].
Hendelman, D ;
Miller, K ;
Bagget, C ;
Debold, E ;
Freedson, P .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (09) :S442-S449
[10]  
JANZ KF, 1995, MED SCI SPORT EXER, V27, P1326