Experimental study on bond properties between GFRP bars and self-compacting concrete

被引:25
作者
Wu, Lili [1 ]
Xu, Xiang [1 ]
Wang, Hui [1 ]
Yang, Jia-Qi [1 ]
机构
[1] China Univ Min & Technol Beijing, Sch Mech & Civil Engn, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
GFRP bar; Self-compacting concrete; Bond strength; Constitutive models; Bond length of GFRP bars; REINFORCED POLYMER REBARS; FRP REBARS; STRENGTH; BEHAVIOR; PERFORMANCE; MODEL;
D O I
10.1016/j.conbuildmat.2021.126186
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In order to investigate the bond properties between glass fiber reinforced polymer (GFRP) bars and selfcompacting concrete (SCC), pull-out tests on 66 GFRP reinforced SCC specimens were designed and carried out. The effects of SCC cover thickness, bond length, and diameter of GFRP bars, as well as the types of fibers added to SCC on the bond properties were investigated. In addition, the failure modes of specimens were analyzed and the bond-slip curve was fitted as well. The conclusion can be described as follows: (1) There are three primary forms of bond failure of specimens: splitting failure, pull-out failure, and pull-out failure with cracks. (2) The bond strength of GFRP bar reinforced SCC specimens can be improved by appropriately increasing the SCC cover thickness and adding fibers to SCC, but it could rapidly decrease with the increasment of GFRP bar diameter and bond length. (3) The CMR model fits well to test data of GFRP/SCC specimens with a larger cover thickness or adding fibers. In comparison, the mBPE model fits well to those with a large diameter or bond length of GFRP bars. The critical bond length of GFRP bars and the recommended thickness of the SCC cover are proposed based on both theoretical and experimental investigations.
引用
收藏
页数:16
相关论文
共 38 条
[1]   Bond behavior of fiber reinforced polymer bars under direct pullout conditions [J].
Achillides, Z ;
Pilakoutas, K .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2004, 8 (02) :173-181
[2]   Bond performances of FRP rebars-reinforced concrete [J].
Aiello, Maria Antonietta ;
Leone, Marianovella ;
Pecce, Marisa .
JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2007, 19 (03) :205-213
[3]   Durability of GFRP Bars' Bond to Concrete under Different Loading and Environmental Conditions [J].
Alves, Juliana ;
El-Ragaby, Amr ;
El-Salakawy, Ehab .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2011, 15 (03) :249-262
[4]   Challenges and opportunities in corrosion of steel in concrete [J].
Angst, Ueli M. .
MATERIALS AND STRUCTURES, 2018, 51 (01)
[5]  
[Anonymous], 2013, 300222013 GBT
[6]  
[Anonymous], 2000, 4401R15 ACI
[7]  
[Anonymous], 2006, 4401R06 ACI
[8]  
BAZANT ZP, 1979, J STRUCT DIV-ASCE, V105, P1137
[9]  
Bradu Aurelia, 2017, Advanced Engineering Forum, V21, P272, DOI 10.4028/www.scientific.net/AEF.21.272
[10]   Unified analytical approach for determining shear capacity of RC beams strengthened with FRP [J].
Colotti, V. ;
Swamy, R. N. .
ENGINEERING STRUCTURES, 2011, 33 (03) :827-842