Radial to femoral arterial blood pressure differences during liver transplantation

被引:42
作者
Arnal, D [1 ]
Garutti, I [1 ]
Perez-Peña, J [1 ]
Olmedilla, L [1 ]
Tzenkov, IG [1 ]
机构
[1] Hosp Gen Univ, Dept Anaesthesia & Reanimat, Madrid, Spain
关键词
D O I
10.1111/j.1365-2044.2005.04257.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
This observational study compared femoral and radial arterial blood pressure in 72 patients undergoing liver transplant surgery. Simultaneous femoral and radial arterial blood pressures, cardiac index, core temperature and vasoconstrictor therapy were recorded at seven time points during the operation. No significant differences between radial and femoral pressures were found at the start of surgery. Femoral and radial systolic arterial blood pressures were statistically significantly different during liver reperfusion (mean (SD) arterial pressure = 92 (22) mmHg vs. 76 (22) mmHg, p < 0.01). Mean arterial blood pressures showed no statistically significant differences throughout the study. Vasoconstrictor drug administration was associated with a larger systolic pressure difference between femoral and radial arteries (28 (24) mmHg in patients being given vasoconstrictor drugs vs. 9 (19) mmHg in patients not needing vasoconstrictors during reperfusion, p < 0.001). In conclusion, differences in systolic arterial blood pressure occur between femoral and radial arterial monitoring sites during liver reperfusion, and in particular in patients being given vasoconstrictor therapy. Thus, if femoral arterial monitoring is not available, clinicians should rely on mean rather than systolic arterial pressure measurements from a radial artery catheter during liver transplantation.
引用
收藏
页码:766 / 771
页数:6
相关论文
共 24 条
[1]   Is femoral and radial artery pressure different during reperfusion in liver transplantation? [J].
Acosta, F ;
Sansano, T ;
Beltran, R ;
Palenciano, CG ;
Reche, M ;
Rogues, V ;
Robles, R ;
Bueno, FS ;
Ramirez, P ;
Parrilla, P .
TRANSPLANTATION PROCEEDINGS, 2000, 32 (08) :2647-2647
[2]   SUPERIORITY OF THE CHILD-PUGH CLASSIFICATION TO QUANTITATIVE LIVER-FUNCTION TESTS FOR ASSESSING PROGNOSIS OF LIVER-CIRRHOSIS [J].
ALBERS, I ;
HARTMANN, H ;
BIRCHER, J ;
CREUTZFELDT, W .
SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1989, 24 (03) :269-276
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Femoral artery pressures are more reliable than radial artery pressures on initiation of cardiopulmonary bypass [J].
Chauhan, S ;
Saxena, N ;
Mehrotra, S ;
Rao, BH ;
Sahu, M .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2000, 14 (03) :274-276
[5]   Radial artery pressure monitoring underestimates central arterial pressure during vasopressor therapy in critically ill surgical patients [J].
Dorman, T ;
Breslow, MJ ;
Lipsett, PA ;
Rosenberg, JM ;
Balser, JR ;
Almog, Y ;
Rosenfeld, BA .
CRITICAL CARE MEDICINE, 1998, 26 (10) :1646-1649
[6]  
Frezza EE, 1998, AM SURGEON, V64, P127
[7]   DIRECT BLOOD-PRESSURE MEASUREMENT - DYNAMIC-RESPONSE REQUIREMENTS [J].
GARDNER, RM .
ANESTHESIOLOGY, 1981, 54 (03) :227-236
[8]   Increased arterial compliance in decompensated cirrhosis [J].
Henriksen, JH ;
Moller, S ;
Schifter, S ;
Bendtsen, F .
JOURNAL OF HEPATOLOGY, 1999, 31 (04) :712-718
[9]   On the accuracy of intra-arterial pressure measurement: The pressure gradient effect [J].
Hynson, JM ;
Katz, JA ;
Mangano, DT .
CRITICAL CARE MEDICINE, 1998, 26 (10) :1623-1624
[10]   THERMOREGULATORY AND ANESTHETIC-INDUCED ALTERATIONS IN THE DIFFERENCES AMONG FEMORAL, RADIAL, AND OSCILLOMETRIC BLOOD PRESSURES [J].
HYNSON, JM ;
SESSLER, DI ;
MOAYERI, A ;
KATZ, JA .
ANESTHESIOLOGY, 1994, 81 (06) :1411-1421