Mercury(II) selective sensors based on AlGaN/GaN transistors

被引:66
作者
Asadnia, Mohsen [1 ,2 ]
Myers, Matthew [3 ,4 ]
Akhavan, N. D. [1 ]
O'Donnell, Kane [5 ]
Umana-Membreno, Gilberto A. [1 ]
Mishra, U. K. [6 ]
Nener, Brett [1 ]
Baker, Murray [3 ]
Parish, Giacinta [1 ]
机构
[1] Univ Western Australia, Sch Elect Elect & Comp Engn, 35 Stirling Hwy, Crawley, WA 6009, Australia
[2] Macquarie Univ, Dept Engn, N Ryde, NSW 2109, Australia
[3] Univ Western Australia, Sch Chem & Biochem, 35 Stirling Hwy, Crawley, WA 6009, Australia
[4] CSIRO, Energy Flagship, Kensington, WA 6151, Australia
[5] Curtin Univ, Dept Imaging & Appl Phys, Bentley, WA 6102, Australia
[6] Univ Calif Santa Barbara, Dept Elect & Comp Engn, Santa Barbara, CA 93106 USA
基金
澳大利亚研究理事会;
关键词
AlGaN; Mercury; Heavy metal detection; ISFET; Polymer membrane; ION; IONOPHORE; ELECTRODE; FIELD;
D O I
10.1016/j.aca.2016.08.045
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work presents the first polymer approach to detect metal ions using AlGaN/GaN transistor-based sensor. The sensor utilised an AlGaN/GaN high electron mobility transistor-type structure by functionalising the gate area with a polyvinyl chloride (PVC) based ion selective membrane. Sensors based on this technology are portable, robust and typically highly sensitive to the target analyte; in this case Hg2+. This sensor showed a rapid and stable response when it was introduced to solutions of varying Hg2+ concentrations. At pH 2.8 in a 10(-2) M KNO3 ion buffer, a detection limit below 10(-8) M and a linear response range between 10(-8) M-10(-4) M were achieved. This detection limit is an order of magnitude lower than the reported detection limit of 10(-7) M for thioglycolic acid monolayer functionalised AlGaN/GaN HEMT devices. Detection limits of approximately 10(-7) M and 10(-6) M in 10(-2) M Cd(NO3)(2) and 10(-2) M Pb(NO3)(2) ion buffers were also achieved, respectively. Furthermore, we show that the apparent gate response was near-Nernstian under various conditions. X-ray photoelectron spectroscopy (XPS) experiments confirmed that the sensing membrane is reversible after being exposed to Hg2+ solution and rinsed with deionised water. The success of this study precedes the development of this technology in selectively sensing multiple ions in water with use of the appropriate polymer based membranes on arrays of devices. Crown Copyright (C) 2016 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 19 条
[1]   A mercury(II) selective sensor based on N,N′-bis(salicylaldehyde)-phenylenediamine as neutral carrier for potentiometric analysis in water samples [J].
Abu-Shawish, Hazem M. .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 167 (1-3) :602-608
[2]   An ion selective electrode for mercury(II) based on mercury(II) complex of poly(4-vinyl pyridine) [J].
Bakhtiarzadeh, Fariba ;
Ab Ghani, Sulaiman .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2008, 624 (1-2) :139-143
[3]   Ultrathin GaN/AlN/GaN solution-gate field effect transistor with enhanced resolution at low source-gate voltage [J].
Bengoechea Encabo, A. ;
Howgate, J. ;
Stutzmann, M. ;
Eickhoff, M. ;
Sanchez-Garcia, M. A. .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 142 (01) :304-307
[4]   A rapid and portable sensor based on protein-modified gold nanoparticle probes and lateral flow assay for naked eye detection of mercury ion [J].
Chao, Cheng-Han ;
Wu, Chung-Shu ;
Huang, Chung-Chih ;
Liang, Jie-Chian ;
Wang, Hsiao-Ting ;
Tang, Pin-Ting ;
Lin, Lih-Yuan ;
Ko, Fu-Hsiang .
MICROELECTRONIC ENGINEERING, 2012, 97 :294-296
[5]   PVC-based hexathia-18-crown-6-tetraone sensor for mercury(II) ions [J].
Fakhari, AR ;
Ganjali, MR ;
Shamsipur, M .
ANALYTICAL CHEMISTRY, 1997, 69 (18) :3693-3696
[6]   Developments in the field of conducting and non-conducting polymer based potentiometric membrane sensors for ions over the past decade [J].
Faridbod, Farnoush ;
Ganjali, Mohammad Reza ;
Dinarvand, Rassoul ;
Norouzi, Parviz .
SENSORS, 2008, 8 (04) :2331-2412
[7]  
Gupta VK, 2003, INDIAN J CHEM A, V42, P813
[8]   Polarization effects, surface states, and the source of electrons in AlGaN/GaN heterostructure field effect transistors [J].
Ibbetson, JP ;
Fini, PT ;
Ness, KD ;
DenBaars, SP ;
Speck, JS ;
Mishra, UK .
APPLIED PHYSICS LETTERS, 2000, 77 (02) :250-252
[9]   MERCURY(II) AND SILVER(I) ION-SELECTIVE ELECTRODES BASED ON DITHIA CROWN ETHERS [J].
LAI, MT ;
SHIH, JS .
ANALYST, 1986, 111 (08) :891-895
[10]   Selective sensing of mercury(II) using PVC-based membranes incorporating recently synthesized 1,3-alternate thiacalix[4]crown ionophore [J].
Mahajan, Rakesh Kumar ;
Kamal, Ajar ;
Kumar, Naresh ;
Bhalla, Vandana ;
Kumar, Manoj .
ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2013, 20 (05) :3086-3097