Mechanism of retention loss when C8 and C18HPLC columns are used with highly aqueous mobile phases

被引:125
作者
Walter, TH [1 ]
Iraneta, P [1 ]
Capparella, M [1 ]
机构
[1] Waters Corp, Milford, MA 01757 USA
关键词
reversed-phase; HPLC; highly aqueous mobile phases; retention loss;
D O I
10.1016/j.chroma.2005.04.039
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We describe investigations into the cause of retention losses encountered when C-8 and C-18 HPLC columns are used with highly aqueous (> 90% water) mobile phases. A procedure for quantifying these losses is described, involving stopping and restarting the flow. This procedure was used to study the dependence of retention loss on the pore size, surface concentration, and chemical structure of the bonded phase. Experiments were also carried out to determine how to restore the original retention of the columns by changing the composition of the mobile phase, or by increasing the pressure applied to the column. The results are shown to be consistent with a mechanism based on the theory of pore filling by non-wetting liquids, as employed in Mercury Porosimetry. The retention losses are attributed to the highly aqueous mobile phase being forced out of the pores when the flow is stopped and the pressure released. Retention is lost because the mobile phase is no longer in contact with the interior surface of the particles, where most of the surface area is located. The implications of this phenomenon for maximizing the reversed phase retention of polar analytes are discussed. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:177 / 183
页数:7
相关论文
共 37 条
[31]  
UNGER KK, 1979, POROUS SILICA, P47
[32]  
WALTER T, 1997, P202A HPLC
[33]   The dynamics of capillary flow. [J].
Washburn, EW .
PHYSICAL REVIEW, 1921, 17 (03) :273-283
[34]   STRUCTURE AND REACTIVITY OF ALKYLSILOXANE MONOLAYERS FORMED BY REACTION OF ALKYLTRICHLOROSILANES ON SILICON SUBSTRATES [J].
WASSERMAN, SR ;
TAO, YT ;
WHITESIDES, GM .
LANGMUIR, 1989, 5 (04) :1074-1087
[35]   SILANOL EFFECTS IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
WELSCH, T ;
FRANK, H ;
VIGH, G .
JOURNAL OF CHROMATOGRAPHY, 1990, 506 :97-108
[36]   REORDERING RESOLVATION OF SILICA IMMOBILIZED NON-HYDROGEN BONDING LIGANDS USED AS STATIONARY PHASES IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
YANG, SS ;
GILPIN, RK .
JOURNAL OF CHROMATOGRAPHY, 1987, 394 (02) :295-303
[37]   EFFECT OF POROUS STRUCTURE ON THE DETERMINATION OF PORE-SIZE DISTRIBUTION BY MERCURY POROSIMETRY AND NITROGEN SORPTION [J].
ZGRABLICH, G ;
MENDIOROZ, S ;
DAZA, L ;
PAJARES, J ;
MAYAGOITIA, V ;
ROJAS, F ;
CONNER, WC .
LANGMUIR, 1991, 7 (04) :779-785