Image quality of low mA CT pulmonary angiography reconstructed with model based iterative reconstruction versus standard CT pulmonary angiography reconstructed with filtered back projection: an equivalency trial

被引:17
作者
Montet, Xavier [1 ]
Hachulla, Anne-Lise [1 ]
Neroladaki, Angeliki [1 ]
Lador, Frederic [2 ]
Rochat, Thierry [2 ]
Botsikas, Diomidis [1 ]
Becker, Christoph D. [1 ]
机构
[1] Univ Hosp Geneva, Div Radiol, CH-1211 Geneva 4, Switzerland
[2] Univ Hosp Geneva, Div Pulm Med, CH-1211 Geneva 4, Switzerland
关键词
Computed tomography pulmonary angiography; Dose; Model-based iterative reconstruction; Signal-to-noise ratio (SNR); Contrast-to-noise ratio (CNR); VENTILATION-PERFUSION SCINTIGRAPHY; MULTIDETECTOR ROW CT; COMPUTED-TOMOGRAPHY; RADIATION-EXPOSURE; DOSE REDUCTION; ABDOMINAL CT; TUBE VOLTAGE; EMBOLISM; CHEST; MANAGEMENT;
D O I
10.1007/s00330-014-3563-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To determine whether CT pulmonary angiography (CTPA) using low mA setting reconstructed with model-based iterative reconstruction (MBIR) is equivalent to routine CTPA reconstructed with filtered back projection (FBP). This prospective study was approved by the institutional review board and patients provided written informed consent. Eighty-two patients were examined with a low mA MBIR-CTPA (100 kV, 20 mA) and 82 patients with a standard FBP-CTPA (100 kV, 250 mA). Region of interests were drawn in nine pulmonary vessels; signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. A five-point scale was used to subjectively evaluate the image quality of FBP-CTPA and low mA MBIR-CTPA. Compared to routine FBP-CTPA, low mA MBIR-CTPA showed no differences in the attenuation measured in nine pulmonary vessels, higher SNR (56 +/- 19 vs 43 +/- 20, p < 0.0001) and higher CNR (50 +/- 17 vs 38 +/- 18, p < 0.0001) despite a dose reduction of 93 % (p < 0.0001). The subjective image quality of low mA MBIR-CTPA was quoted as diagnostic in 98 % of the cases for patient with body mass index less than 30 kg/m(2). Low mA MBIR-CTPA is equivalent to routine FBP-CTPA and allows a significant dose reduction while improving SNR and CNR in the pulmonary vessels, as compared with routine FBP-CTPA.
引用
收藏
页码:1665 / 1671
页数:7
相关论文
共 34 条
[1]  
[Anonymous], 1999, 16262 EUR
[2]   Through the Looking Glass Revisited: The Need for More Meaning and Less Drama in the Reporting of Dose and Dose Reduction in CT [J].
Bankier, Alexander A. ;
Kressel, Herbert Y. .
RADIOLOGY, 2012, 265 (01) :4-8
[3]   Investigation of American Association of Physicists in Medicine Report 204 Size-specific Dose Estimates for Pediatric CT Implementation [J].
Brady, Samuel L. ;
Kaufman, Robert A. .
RADIOLOGY, 2012, 265 (03) :832-840
[4]   Size-specific Dose Estimation for CT: How Should It Be Used and What Does It Mean? [J].
Brink, James A. ;
Morin, Richard L. .
RADIOLOGY, 2012, 265 (03) :666-668
[5]   Methodology of superiority vs. equivalence trials and non-inferiority trials [J].
Christensen, Erik .
JOURNAL OF HEPATOLOGY, 2007, 46 (05) :947-954
[6]   Diagnosis of acute pulmonary embolism in outpatients: Comparison of thin-collimation multi-detector row spiral CT and planar ventilation-perfusion scintigraphy [J].
Coche, E ;
Verschuren, F ;
Keyeux, A ;
Goffette, P ;
Goncette, L ;
Hainaut, P ;
Hammer, F ;
Lavenne, E ;
Zech, F ;
Meert, P ;
Reynaert, MS .
RADIOLOGY, 2003, 229 (03) :757-765
[7]   Filtered Back Projection, Adaptive Statistical Iterative Reconstruction, and a Model-based Iterative Reconstruction in Abdominal CT: An Experimental Clinical Study [J].
Deak, Zsuzsanna ;
Grimm, Jochen M. ;
Treitl, Marcus ;
Geyer, Lucas L. ;
Linsenmaier, Ulrich ;
Koerner, Markus ;
Reiser, Maximilian F. ;
Wirth, Stefan .
RADIOLOGY, 2013, 266 (01) :197-206
[8]   Radiation dose in helical CT for detection of pulmonary embolism [J].
Diederich, S .
EUROPEAN RADIOLOGY, 2003, 13 (07) :1491-1493
[9]   Short-term Mortality in Acute Pulmonary Embolism: Clot Burden and Signs of Right Heart Dysfunction at CT Pulmonary Angiography [J].
Furlan, Alessandro ;
Aghayev, Ayaz ;
Chang, Chung-Chou H. ;
Patil, Amol ;
Jeon, Kyung Nyeo ;
Park, Bumwoo ;
Fetzer, David T. ;
Saul, Melissa ;
Roberts, Mark S. ;
Bae, Kyongtae T. .
RADIOLOGY, 2012, 265 (01) :283-293
[10]   Impact of Tube Current-Time and Tube Voltage Reduction in 64-Detector-row Computed Tomography Pulmonary Angiography for Pulmonary Embolism in a Porcine Model [J].
Henes, Frank Oliver Gerhard ;
Groth, Michael ;
Begemann, Philipp G. C. ;
Bley, Thorsten ;
Adam, Gerhard ;
Regier, Marc .
JOURNAL OF THORACIC IMAGING, 2012, 27 (02) :113-120