Development and Validation of Salt Gradient CEX Chromatography Method for Charge Variants Separation and Quantitative Analysis of the IgG mAb-Cetuximab

被引:15
作者
Farjami, Afsaneh [1 ,2 ,3 ]
Siahi-Shadbad, Mohammadreza [1 ,2 ]
Akbarzadehlaleh, Parvin [1 ]
Molavi, Ommoleila [1 ]
机构
[1] Tabriz Univ Med Sci, Fac Pharm, Tabriz, Iran
[2] Tabriz Univ Med Sci, Food & Drug Safety Res Ctr, Tabriz, Iran
[3] Tabriz Univ Med Sci, Student Res Comm, Tabriz, Iran
关键词
Cation exchange chromatography; Charge heterogeneity; Method validation; Monoclonal antibody; Cetuximab; CATION-EXCHANGE CHROMATOGRAPHY; MONOCLONAL-ANTIBODY; MIDDLE-UP; HETEROGENEITY; PURIFICATION; INTACT;
D O I
10.1007/s10337-018-3627-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Ion exchange chromatography is widely used for charge variant analysis of proteins, including monoclonal antibodies. In this study, a simple and robust salt gradient cation exchange chromatography was developed and validated for quantitative determination of cetuximab in biopharmaceutical formulations. For this purpose, we investigated the effect of various parameters including buffer composition, column temperature, pH, gradient volume and flow rate on chromatographic separation of charge variants to achieve the acceptable peak separation, and the optimum condition was selected. Validation of the method was done in accordance with the International Conference on Harmonization (ICH) guidelines. The developed method was found to provide a linear regression over the concentration range of 0.06-2.00mg mL(-1) yielding acorrelation coefficient of 0.9972. The limits of detection and quantification for the developed method were 0.02 and 0.06mg mL(-1), respectively. The intra-day and inter-day precision had relative standard deviation values2.7%. The robustness of the method was assessed by changes in the applied pH range of buffer, temperature, mobile phase composition, and flow rate. Specificity of the method was confirmed by evaluation of baseline resolution of the mAb variants from product excipients, which showed no interference between excipients and cetuximab. The stability indicating capability of this method was determined using photodegraded, and mechanically and thermally stressed samples. The proposed method could be applied as a simple, precise, and robust quantitative technique which can be reproduced in any labs for the high-throughput quality control and stability assessment of in-process and final product samples.
引用
收藏
页码:1649 / 1660
页数:12
相关论文
共 38 条
[1]  
[Anonymous], 2005, INT C HARM GEN SWITZ
[2]  
[Anonymous], 1995, ICH INT C HARM TECHN
[3]  
[Anonymous], 1996, ICH INT C HARM TECHN
[4]   Correct primary structure assessment and extensive glyco-profiling of cetuximab by a combination of intact, middle-up, middle-down and bottom-up ESI and MALDI mass spectrometry techniques [J].
Ayoub, Daniel ;
Jabs, Wolfgang ;
Resemann, Anja ;
Evers, Waltraud ;
Evans, Catherine ;
Main, Laura ;
Baessmann, Carsten ;
Wagner-Rousset, Elsa ;
Suckau, Detlev ;
Beck, Alain .
MABS, 2013, 5 (05) :699-710
[5]   Development of validated stability-indicating assay methods - critical review [J].
Bakshi, M ;
Singh, S .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 28 (06) :1011-1040
[6]  
Beck A., 2012, Biosimilar, biobetter, and next generation antibody characterization by mass spectrometry
[7]   Trends in Glycosylation, Glycoanalysis and Glycoengineering of Therapeutic Antibodies and Fc-Fusion Proteins [J].
Beck, Alain ;
Wagner-Rousset, Elsa ;
Bussat, Marie-Claire ;
Lokteff, Maryline ;
Klinguer-Hamour, Christine ;
Haeuw, Jean-Francois ;
Goetsch, Liliane ;
Wurch, Thierry ;
Van Dorsselaer, Alain ;
Corvaia, Nathalie .
CURRENT PHARMACEUTICAL BIOTECHNOLOGY, 2008, 9 (06) :482-501
[8]   Glycoform Separation and Characterization of Cetuximab Variants by Middle-up Off-Line Capillary Zone Electrophoresis-UV/Electrospray Ionization-MS [J].
Biacchi, Michael ;
Gahoual, Rabah ;
Said, Nassur ;
Beck, Alain ;
Leize-Wagner, Emmanuelle ;
Francois, Yannis-Nicolas .
ANALYTICAL CHEMISTRY, 2015, 87 (12) :6240-6250
[9]   Multiproduct High-Resolution Monoclonal Antibody Charge Variant Separations by pH Gradient Ion-Exchange Chromatography [J].
Farnan, Dell ;
Moreno, G. Tony .
ANALYTICAL CHEMISTRY, 2009, 81 (21) :8846-8857
[10]   Ion-exchange chromatography for the characterization of biopharmaceuticals [J].
Fekete, Szabolcs ;
Beck, Alain ;
Veuthey, Jean-Luc ;
Guillarme, Davy .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2015, 113 :43-55