Thermal behavior of a solar-assisted latent heat thermal energy storage unit on the heating season under variable weather conditions

被引:9
作者
Cam, Nezir Yagiz [1 ,2 ]
Alptekin, Ersin [3 ]
Bilir, Levent [1 ]
Ezan, Mehmet Akif [3 ]
机构
[1] Yasar Univ, Energy Syst Engn Dept, Izmir, Turkey
[2] Dokuz Eylul Univ, Grad Sch Nat & Appl Sci, Izmir, Turkey
[3] Dokuz Eylul Univ, Fac Engn, Dept Mech Engn, Izmir, Turkey
关键词
Thermal energy storage; PCM; Solar energy; Heat pump; Economic assessment; PERFORMANCE; SOLIDIFICATION;
D O I
10.1016/j.est.2022.104934
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Due to the fossil-fuel-related climatic problems which got worse in recent decades, the worldwide share of renewable energy has significantly increased. Even though solar energy is one of the most accessible renewables, it has an intermittent nature throughout the day. Different energy storage techniques are implemented to resolve the intermittency problem and make solar-aided energy accessible when it is needed. Energy use in buildings has a huge share of total energy demand, and heating/cooling demands are responsible for most energy consumption in buildings. In this study, the performance of a solar-assisted latent heat thermal energy storage (LHTES) unit integrated with a heat pump is investigated during the heating season under variable weather conditions. Phase change materials (PCMs) with different melting temperatures (T-m) and latent heat of fusions (h(sf)) are studied, and parametric simulations are conducted to examine the proposed systems' economic advantage and payback duration. Variable weather conditions are defined in simulations, and seven consecutive day analyses are conducted to ensure that results are not dependent on the initial conditions. Results revealed that the PCM with T-m= 35 degrees C and h(sf) = 240 kJ/kg has a better thermal performance than the other alternatives, i.e., T-m = 31 degrees C and 40 degrees C. The integration of the solar-aided LHTES unit with the heat pump increases the COP of the heat pump, and the increment varies from 35% to 80% for heating months in Izmir. Such an improvement in COP reduces the operating costs related to the electricity consumption of the heating device significantly, and the simple payback period of the combined system is determined to be approximately 13 years in Izmir.
引用
收藏
页数:14
相关论文
共 25 条
  • [1] Performance investigations on a sensible heat thermal energy storage tank with a solar collector under variable climatic conditions
    Alptekin, Ersin
    Ezan, Mehmet Akif
    [J]. APPLIED THERMAL ENGINEERING, 2020, 164
  • [2] [Anonymous], 1974, Solar energy thermal processes
  • [3] [Anonymous], Exchange Rates
  • [4] Performance and sustainability assessment of energy options for building HVAC applications
    Balta, M. Tolga
    Dincer, Ibrahim
    Hepbasli, Arif
    [J]. ENERGY AND BUILDINGS, 2010, 42 (08) : 1320 - 1328
  • [5] Numerical evaluation of a triple concentric-tube latent heat thermal energy storage
    Basal, Birol
    Unal, Ahmet
    [J]. SOLAR ENERGY, 2013, 92 : 196 - 205
  • [6] A NUMERICAL-ANALYSIS OF PHASE-CHANGE PROBLEMS INCLUDING NATURAL-CONVECTION
    CAO, Y
    FAGHRI, A
    [J]. JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1990, 112 (03): : 812 - 816
  • [7] Cengel YA., 2007, THERMODYNAMICS ENG A
  • [8] Dincer I, 2018, GREEN ENERGY TECHNOL, P1, DOI 10.1007/978-3-319-91893-8
  • [9] Thermal performance analysis of combined solar collector with triple concentric-tube latent heat storage systems
    Elbahjaoui, Radouane
    El Qarnia, Hamid
    Naimi, Abdelouahed
    [J]. ENERGY AND BUILDINGS, 2018, 168 : 438 - 456
  • [10] Energy Market Regulatory Authority, EL TAR LIST