High-resolution multi-detector SPET imaging of the paediatric spine

被引:0
|
作者
Kriss, VM [1 ]
Elgazzar, AH [1 ]
Gelfand, MJ [1 ]
Golsch, GJ [1 ]
机构
[1] CHILDRENS HOSP,MED CTR,DEPT RADIOL,CINCINNATI,OH 45229
关键词
D O I
10.1097/00006231-199602000-00005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We reviewed the planar and single photon emission tomographic (SPET) spine images of 69 paediatric patients aged 2-17 years referred for undiagnosed back pain. The SPET images were obtained using a triple-detector camera and ultra-high-resolution collimation. Abnormal images were rated as slightly positive (1+) or strongly positive (2+). The planar and SPET images were normal in 48 of 69 patients. Thirteen of the remaining 21 cases had negative planar imaging with positive SPET images (SPET was 2+ in 10 cases and 1+ in 3 cases). Four of the 21 cases were 1+ on planar imaging, but clearly positive (2+) cin tho SPET images. Three of the 21 cases had 2+ planar abnormalities, but SPET demonstrated additional uptake abnormalities. Lastly, a single case that was 2+ on the planar images was demonstrated to be artefactual by SPET. Thirty-seven sites were abnormal by SPET, including 17 pedicle/pars interarticularis (11 patients), 10 spinous process (8 patients), 8 vertebral endplate (2 patients) and 2 vertebral body (2 patients) abnormalities. Sites that were abnormal on SPET and normal on planar imaging included 10 of 17 (59%) in the pedicle/pars region, 9 of 10 (90%) in the spinous process, 1 of 2 (50%) in the vertebral body and 2 of 8 (25%) in the vertebral endplates. The improved resolution of ultra-high-resolution collimated multi-detector SPET permits visualization of a greater variety of abnormalities than was seen with earlier single-detector cameras, particularly those involving the spinous process.
引用
收藏
页码:119 / 124
页数:6
相关论文
共 50 条
  • [21] Quantitative near field imaging with multi-detector waveguide
    Steegmuller, R
    Diener, L
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 16A AND 16B, 1997, 16 : 673 - 678
  • [22] The role of multi-detector computed tomography in imaging hernias
    Laurence, Isabel
    Ngan-Soo, Eleanor
    Gandhi, Sanjay
    BRITISH JOURNAL OF HOSPITAL MEDICINE, 2011, 72 (02) : 72 - 77
  • [23] High resolution multi-detector CT aided tissue analysis and quantification of lung fibrosis
    Zavaletta, Vanessa A.
    Karwoski, Ronald A.
    Bartholmai, Brian
    Robb, Richard A.
    MEDICAL IMAGING 2006: PHYSIOLOGY, FUNCTION, AND STRUCTURE FROM MEDICAL IMAGES PTS 1 AND 2, 2006, 6143
  • [24] Local Dose Survey on Paediatric Multi-detector CT: A Preliminary Result
    Lubis, L. E.
    Jundi, A. F.
    Susilo, A.
    Evianti, A.
    Soejoko, D. S.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 3, 2019, 68 (03): : 571 - 575
  • [25] HIGH-RESOLUTION TOPOGRAPHY DETECTOR
    CHIKAWA, J
    SATO, F
    FUJIMOTO, I
    ACTA CRYSTALLOGRAPHICA SECTION A, 1984, 40 : C403 - C403
  • [26] A HIGH-RESOLUTION MUON DETECTOR
    ADEVA, B
    AGUILARBENITEZ, M
    ALCARAZ, J
    ALOISIO, A
    ALVIGGI, MG
    ANTREASYAN, D
    BECKER, U
    BERDUGO, J
    BOBBINK, GJ
    BRAMBILLA, E
    BRANSON, JD
    BUJAK, A
    BURGOS, C
    BURGER, JD
    CARLINO, G
    CERRADA, M
    CHANG, YH
    CHIEFARI, G
    COLINO, N
    DRAGO, E
    DUINKER, P
    DURAN, I
    ERNE, F
    FABBRETTI, R
    FABRE, M
    GAU, SS
    GETTNER, M
    GONZALEZ, E
    VANDERGRAAF, H
    GUESEWELL, D
    GUTAY, LG
    HARTJES, FG
    HU, G
    INNOCENTE, V
    JIN, BN
    KONIG, AC
    KUMMAR, KS
    LANZANO, S
    LEGOFF, JM
    LEIJTENS, X
    LI, L
    MANA, C
    MAO, YF
    MARTINEZLASO, L
    MASSARO, GGG
    MCBRIDE, P
    MCMAHON, T
    MEROLA, L
    ONVLEE, H
    PATERNOSTER, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 323 (1-2): : 109 - 124
  • [27] Functional Imaging Combined with Multi-Detector CT: A Radionuclide Imaging Perspective
    Winant, Celeste D.
    Kim, Sangtaek
    Seo, Youngho
    CURRENT MEDICAL IMAGING, 2010, 6 (02) : 100 - 111
  • [28] Multi-detector CT-colonography in inflammatory bowel disease:: Prospective analysis of CT-findings to high-resolution video colonoscopy
    Andersen, K
    Vogt, C
    Blondin, D
    Beck, A
    Heinen, W
    Aurich, V
    Häussinger, D
    Mödder, U
    Cohnen, M
    EUROPEAN JOURNAL OF RADIOLOGY, 2006, 58 (01) : 140 - 146
  • [29] A novel scatter detector for high-resolution SPECT imaging with Compton telescopes
    Castoldi, A.
    Galimberti, A.
    Guazzoni, C.
    Strueder, L.
    Walenta, A. H.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (06) : 3912 - 3917
  • [30] Performance Evaluation of a Commercial CMOS Detector for Dynamic High-Resolution Imaging
    Jain, A.
    Ionita, C.
    Bednarek, D.
    Rudin, S.
    MEDICAL PHYSICS, 2013, 40 (06)