Dislocation of a dual mobility total hip replacement following fracture of the polyethylene liner

被引:1
|
作者
Vedrine, Bertrand [1 ]
Guillaumot, Pierre [2 ]
Chancrin, Jean-Luc [2 ]
机构
[1] Clin Vet Cauchoise, 5 Pl Cauchoise, F-76000 Rouen, France
[2] Clin Vet Olliolis, Ollioules, France
关键词
Hip; replacement; prosthesis; dual mobility; dislocation; ACETABULAR COMPONENT; FEMORAL COMPONENT; RISK-FACTORS; ARTHROPLASTY; DOGS; LUXATION; IMPLANT; 5-YEAR; PROSTHESIS; POSTMORTEM;
D O I
10.3415/VCOT-15-01-0016
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
An eight-year-old male English Setter was referred for management of a dislocation of a cemented dual mobility canine total hip prosthesis that occurred four months after the initial surgery. Revision surgery showed that the dislocation was associated with fracture of the ultra-high molecular weight polyethylene liner. The dislocation was successfully reduced after replacing the liner. A dual mobility acetabular component is composed of a mobile polyethylene liner inside a metallic cemented cup. Chronic wear of the components of a canine dual mobility total hip replacement has not been described previously. The use of this type of implant is fairly recent and limited long term follow-up of the implanted cases may be the explanation. Acute rupture of a polyethylene liner has never been described in humans, the only case of rupture of a polyethylene liner occurred 10 years after implantation. The case presented here of rupture of the polyethylene liner of a dual mobility total hip replacement is a hitherto unreported failure mode in this model of acetabular cup in the dog.
引用
收藏
页码:259 / 264
页数:6
相关论文
共 50 条
  • [1] Outcome and complications after dual mobility total hip replacement Fifty cases with a minimum of six months clinical and radiographic follow-up
    Guillaumot, P.
    Autefage, A.
    Dembour, T.
    Chancrin, J-L.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2012, 25 (06) : 511 - 517
  • [2] Polyethylene liner fracture in dual mobility trapeziometacarpal total joint replacement: how to make a timely diagnosis?
    Duerinckx, Joris
    Caekebeke, Pieter
    Van Melkebeke, Laurens
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2024, 49 (08) : 1034 - 1035
  • [3] Dislocation of Total Hip Replacement in Femoral Neck Fracture: Do Surgical Approach and Dual Mobility Implant Matter?
    Goru, Poornanand
    Haque, Syed
    Verma, Gopalkrishna G.
    Mustafa, Abubakar
    Hamed, Mostafa
    Ismail, Mobeen
    Shah, Sanat
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (01)
  • [4] Dual mobility canine total hip prosthesis: Implant characteristics and surgical procedure
    Guillaumot, P.
    Autefage, A.
    Palierne, S.
    Dembour, T.
    Chancrin, J-L.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2012, 25 (06) : 506 - 510
  • [5] Dual Mobility Head in Total Hip Replacement for Instability: A Systematic Review
    Alharbi, Mohammed
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2021, 9 (12): : 22 - 31
  • [6] Dual mobility design socket use in preventing total hip replacement dislocation following tumor resection
    Philippeau, J. -M.
    Durand, J. -M.
    Carret, J. -P.
    Leclercq, S.
    Waast, D.
    Gouin, F.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2010, 96 (01) : 1 - 7
  • [7] Damage of an Oxinium femoral head and polyethylene liner following 'routine' total hip replacement
    McCalden, R. W.
    Charron, K. D.
    Davidson, R. D.
    Teeter, M. G.
    Holdsworth, D. W.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (03): : 409 - 413
  • [8] Intraprosthetic Dislocation Following Dual Mobility Total Hip Arthroplasty: A Retrieval Analysis Study
    Sobhi, Salar
    Kop, Alan
    Pabbruwe, Moreica
    Jones, Christopher W.
    Finsterwald, Michael A.
    ARTHROPLASTY TODAY, 2025, 31
  • [9] Lack of early dislocation following total hip arthroplasty with a new dual mobility acetabular design
    Vigdorchik, Jonathan M.
    D'Apuzzo, Michele R.
    Markel, David C.
    Malkani, Arthur L.
    Raterman, Stephen
    Sharpe, Kipling P.
    Cornell, Charles N.
    Westrich, Geoffrey H.
    HIP INTERNATIONAL, 2015, 25 (01) : 34 - 38
  • [10] Long-term wear of dual mobility total hip replacement cups: explant study
    Boyer, Bertrand
    Neri, Thomas
    Geringer, Jean
    Di Iorio, Alexandre
    Philippot, Remi
    Farizon, Frederic
    INTERNATIONAL ORTHOPAEDICS, 2018, 42 (01) : 41 - 47