In vivo biophysical characterization of very high power, short duration, temperature-controlled lesions

被引:10
作者
Stabile, Giuseppe [1 ,2 ,3 ]
Schillaci, Vincenzo [1 ]
Strisciuglio, Teresa [1 ,4 ]
Arestia, Alberto [1 ]
Agresta, Alessia [1 ]
Shopova, Gergana [1 ]
De Simone, Antonio [2 ]
Solimene, Francesco [1 ]
机构
[1] Clin Montevergine, Avellino, Italy
[2] Clin San Michele, Maddaloni, Caserta, Italy
[3] Anthea Hosp, Bari, Italy
[4] Univ Naples Federico II, Dept Adv Biomed Sci, Naples, Italy
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2021年 / 44卷 / 10期
关键词
atrial fibrillation; catheter ablation; high power short duration; ELECTRODE-TISSUE CONTACT; PULMONARY VEIN ISOLATION; ATRIAL-FIBRILLATION; ABLATION; IMPEDANCE; CATHETER; FORCE;
D O I
10.1111/pace.14358
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction A very high-power short-duration (vHPSD) strategy of radiofrequency (RF) ablation aims to minimize conductive heating and increase resistive heating. This study aimed to clarify the contribution of contact force (CF) and temperature and their interrelationship in making an adequate lesion with the vHPSD catheter. Methods We enrolled 46 consecutive patients undergoing first catheter ablation for atrial fibrillation (AF). The vHPSD ablation was performed applying 90 W, for 4 s, with an irrigation of 8 ml/min. During an application, an impedance drop (ID) >= 10 omega was regarded as an adequate lesion formation. Results The mean procedural time was 95 +/- 15 min. First-pass isolation was reached in 89% of patients and at the end of the procedure all pulmonary veins were isolated. No steam pop nor procedural complication occurred. A total of 3829 qualified RF points were analyzed and the median values of ID, CF and maximum temperature were respectively 10.6 (IQR 8.6-13.1) Ohm, 9 (5.8-13.8) g, 46.8 (44.1-49.8) degrees C. The mean ID significantly increased in parallel with the increasing CF as well as with the increasing maximum temperature. In the multivariable analysis only the CF and the maximum temperature were independent predictors of ID. From receiver operating characteristic curve analysis, a CF of 8 g and a maximum temperature of 47 degrees C are the optimal cutoff discriminatory value for adequate lesion formation. Conclusions The vHPSD ablation is highly effective and safe. The CF and the maximum temperature are independent predictors of adequate lesion formation assessed by means of ID.
引用
收藏
页码:1717 / 1723
页数:7
相关论文
共 15 条
  • [1] The effects of electrode-tissue contact on radiofrequency lesion generation
    Avitall, B
    Mughal, K
    Hare, J
    Helms, R
    Krum, D
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (12): : 2899 - 2910
  • [2] High-power and short-duration ablation for pulmonary vein isolation: Safety, efficacy, and long-term durability
    Barkagan, Michael
    Contreras-Valdes, Fernando M.
    Leshem, Eran
    Buxton, Alfred E.
    Nakagawa, Hiroshi
    Anter, Elad
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (09) : 1287 - 1296
  • [3] Calkins H, 2017, J ARRYTHM, V33, P369, DOI 10.1016/j.joa.2017.08.001
  • [4] Blocking the Pulmonary Vein to Left Atrium Conduction in Addition to the Entrance Block Enhances Clinical Efficacy in Atrial Fibrillation Ablation
    Chen, Songwen
    Meng, Weidong
    He, Ding Sheng
    Chen, Gang
    Zhang, Feng
    Yan, Yiwen
    Zhu-Ge, Ying
    Liu, Shaowen
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (05): : 524 - 531
  • [5] Ablation Effect Indicated by Impedance Fall is Correlated with Contact Force Level During Ablation for Atrial Fibrillation
    De Bortoli, Alessandro
    Sun, Li-Zhi
    Solheim, Eivind
    Hoff, Per Ivar
    Schuster, Peter
    Ohm, Ole-Jorgen
    Chen, Jian
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2013, 24 (11) : 1210 - 1215
  • [6] IMPEDANCE MONITORING DURING RADIOFREQUENCY CATHETER ABLATION IN HUMANS
    HARVEY, M
    KIM, YN
    SOUSA, J
    ELATASSI, R
    MORADY, F
    CALKINS, H
    LANGBERG, JJ
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (01): : 22 - 27
  • [7] HINDRICKS G, 2021, EUR HEART J, V42, P373, DOI [DOI 10.1093/eurheartj/ehaa612, DOI 10.1093/EURHEARTJ/EHAA612]
  • [8] Relationship Between Catheter Contact Force and Radiofrequency Lesion Size and Incidence of Steam Pop in the Beating Canine Heart Electrogram Amplitude, Impedance, and Electrode Temperature Are Poor Predictors of Electrode-Tissue Contact Force and Lesion Size
    Ikeda, Atsushi
    Nakagawa, Hiroshi
    Lambert, Hendrik
    Shah, Dipen C.
    Fonck, Edouard
    Yulzari, Aude
    Sharma, Tushar
    Pitha, Jan V.
    Lazzara, Ralph
    Jackman, Warren M.
    [J]. CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2014, 7 (06) : 1174 - 1180
  • [9] Temperature-Controlled Radiofrequency Ablation Using Irrigated Catheters Maximizing Ventricular Lesion Dimensions While Reducing Steam-Pop Formation
    Leshem, Eran
    Zilberman, Israel
    Barkagan, Michael
    Shapira-Daniels, Ayelet
    Sroubek, Jakub
    Govari, Assaf
    Buxton, Alfred E.
    Anter, Elad
    [J]. JACC-CLINICAL ELECTROPHYSIOLOGY, 2020, 6 (01) : 83 - 93
  • [10] High-Power and Short-Duration Ablation for Pulmonary Vein Isolation Biophysical Characterization
    Leshem, Eran
    Zilberman, Israel
    Tschabrunn, Cory M.
    Barkagan, Michael
    Contreras-Valdes, Fernando M.
    Govari, Assaf
    Anter, Elad
    [J]. JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (04) : 467 - 479