Personal protective equipment and doffing procedures in out-of-hospital practice: assessment with a contamination simulation

被引:5
作者
Pottier, Fabrice [1 ]
Groizard, Charles [1 ]
Briche, Gregory [2 ]
Haraczaj, Nicolas [3 ]
Garnier, Maxime [3 ]
Loones, Vinciane [3 ]
Ozguler, Anna [1 ]
Baer, Michel [1 ]
Baer, Geraldine [4 ]
Loeb, Thomas [1 ]
机构
[1] SAMU 92, AP HP, 104 Blvd Raymond Poincare, F-92380 Garches, France
[2] Inst Rech Criminelle Gendarmerie Natl, Div Criminalist Phys & Chim, Cergy Pontoise, France
[3] Inst Rech Criminelle Gendarmerie Natl, Dept Environm Incendie Explosifs, Cergy Pontoise, France
[4] Univ Penn, Med Ctr, Corporal Michael J Crescenz VA Med Ctr, Dept Emergency Med, Philadelphia, PA 19104 USA
关键词
Emergency medical service; Personal protective equipment; Simulation; Healthcare workers; Doffing; COVID-19;
D O I
10.1186/s12245-021-00362-9
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background The use of personal protective equipment (PPE) by emergency medical services (EMS) providers requires specific attention, as it takes place in out-of-hospital unsecured settings. The aim of this study was to evaluate which PPE gown was less contaminating during doffing procedures in an EMS setting. Six well-trained healthcare worker (HCW) subjects tested 4 different gowns: (1) surgical gowns (SG), (2) full body coveralls (FBC), (3) self-made alternative PPEs (SMP), and (4) non-surgical isolation gowns (NSIG). An invisible tracer was sprayed on the gown after donning each subject. After doffing, each HCW was photographed under UV lights to show areas of fluorescent "contamination" on their clothes. The number, size, and intensity level of contaminated areas were noted, as well as observational deviation from the procedure and doffing time. In addition, the subjects were asked to take a questionnaire about their perception of the level of comfort, ease of doffing, and overall safety for each gown. Results Despite a well-trained team of HCW subjects, contamination while doffing was observed with every type of PPE gown, and with each HCW subject. All body areas were contaminated at least once, except the face. Contamination was more frequent while doffing FBCs. On the other hand, the removal of SG was found to be the least contaminating. The mean doffing time was significantly shorter with SG 1:29 and longer with FBC 2:26 (p=0.005). Conclusion Results of this study converge towards the selection of surgical gowns over other types of PPE gowns, which met both contamination criteria as well as staff appreciation in this context. Specific attention should be paid to the legs and abdomino-pelvic areas. Additional protection such as protective trousers or aprons could be added.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Human-machine collaboration using artificial intelligence to enhance the safety of donning and doffing personal protective equipment (PPE)
    Segal, Reny
    Bradley, William Pierre
    Williams, Daryl Lindsay
    Lee, Keat
    Krieser, Roni Benjamin
    Mezzavia, Paul Mario
    Nunes, Rommie Correa de Araujo
    Ng, Irene
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2023, 44 (05) : 732 - 735
  • [32] Emergency department impaired adherence to personal protective equipment donning and doffing protocols during the COVID-19 pandemic
    Tomer Lamhoot
    Noa Ben Shoshan
    Hagit Eisenberg
    Gilad Fainberg
    Mansour Mhiliya
    Neta Cohen
    Orly Bisker-Kassif
    Orly Barak
    Carolyn Weiniger
    Tali Capua
    Israel Journal of Health Policy Research, 10
  • [33] Effects of Education on the Use of Personal Protective Equipment for Reduction of Contamination: A Randomized Trial
    Yeon, Jeong Hwa
    Shin, Yong Soon
    SAGE OPEN NURSING, 2020, 6
  • [34] Predicting Health Care Workers' Tolerance of Personal Protective Equipment: An Observational Simulation Study
    Martin-Rodriguez, Francisco
    Sanz-Garcia, Ancor
    Lopez-Izquierdo, Raul
    Delgado Benito, Juan F.
    Martin-Conty, Jose L.
    Castro Villamor, Miguel A.
    Ortega, Guillermo J.
    CLINICAL SIMULATION IN NURSING, 2020, 47 : 65 - 72
  • [35] Healthcare design to improve safe doffing of personal protective equipment for care of patients with COVID-19
    Machry, Herminia
    Matic, Zorana
    Oh, Yeinn
    DuBose, Jennifer R.
    Morgan, Jill S.
    Love, Kari L.
    Jacob, Jesse T.
    Zimring, Craig M.
    INFECTION CONTROL & HOSPITAL EPIDEMIOLOGY, 2022, 43 (12) : 1796 - 1805
  • [36] A Gesture Controlled System to Train and Guide the Healthcare Workers While Donning and Doffing Personal Protective Equipment
    Qin, PengLin
    Xu, GuangHua
    Wu, QingQiang
    Wei, Fan
    Li, ZeJiang
    Zhao, Dakai
    2022 IEEE-EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES, IECBES, 2022, : 318 - 323
  • [37] Potential application of novel technology developed for instant decontamination of personal protective equipment before the doffing step
    Breda Mascarenhas, Luis Alberto
    Machado, Bruna Aparecida Souza
    Rodrigues, Leticia de Alencar Pereira
    Saraiva Hodel, Katharine Valeria
    Bandeira Santos, Alex Alisson
    Freitas Neves, Paulo Roberto
    da Silva Andrade, Leone Peter Correia
    Soares, Milena Botelho
    de Andrade, Jailson Bittencourt
    Badaro, Roberto
    PLOS ONE, 2021, 16 (06):
  • [38] Life-Saving Procedures Performed While Wearing CBRNe Personal Protective Equipment A Mannequin Randomized Trial
    Mormando, Giulia
    Paganini, Matteo
    Alexopoulos, Chiara
    Savino, Sandro
    Bortoli, Nicola
    Pomiato, Daniele
    Graziano, Alessandro
    Navalesi, Paolo
    Fabris, Fabrizio
    SIMULATION IN HEALTHCARE-JOURNAL OF THE SOCIETY FOR SIMULATION IN HEALTHCARE, 2021, 16 (06): : E200 - E205
  • [39] Headache in healthcare workers related to personal protective equipment use in COVID-19 referral hospital
    Wijayanti, Ida Ayu Sri
    Mahadewi, Ni Putu Ayu Putri
    Sudira, Putu Gede
    Tini, Kumara
    Susilawathi, Ni Made
    Adnyana, I. Made Oka
    UNIVERSA MEDICINA, 2023, 42 (01) : 52 - 60
  • [40] Medical Student Personal Protective Equipment Training Through Simulated Contamination
    Zach K.M.
    Maloney L.M.
    Praslick A.D.
    Wackett A.
    Seidman P.A.
    Medical Science Educator, 2016, 26 (4) : 517 - 518