Personal protective equipment and doffing procedures in out-of-hospital practice: assessment with a contamination simulation

被引:5
作者
Pottier, Fabrice [1 ]
Groizard, Charles [1 ]
Briche, Gregory [2 ]
Haraczaj, Nicolas [3 ]
Garnier, Maxime [3 ]
Loones, Vinciane [3 ]
Ozguler, Anna [1 ]
Baer, Michel [1 ]
Baer, Geraldine [4 ]
Loeb, Thomas [1 ]
机构
[1] SAMU 92, AP HP, 104 Blvd Raymond Poincare, F-92380 Garches, France
[2] Inst Rech Criminelle Gendarmerie Natl, Div Criminalist Phys & Chim, Cergy Pontoise, France
[3] Inst Rech Criminelle Gendarmerie Natl, Dept Environm Incendie Explosifs, Cergy Pontoise, France
[4] Univ Penn, Med Ctr, Corporal Michael J Crescenz VA Med Ctr, Dept Emergency Med, Philadelphia, PA 19104 USA
关键词
Emergency medical service; Personal protective equipment; Simulation; Healthcare workers; Doffing; COVID-19;
D O I
10.1186/s12245-021-00362-9
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background The use of personal protective equipment (PPE) by emergency medical services (EMS) providers requires specific attention, as it takes place in out-of-hospital unsecured settings. The aim of this study was to evaluate which PPE gown was less contaminating during doffing procedures in an EMS setting. Six well-trained healthcare worker (HCW) subjects tested 4 different gowns: (1) surgical gowns (SG), (2) full body coveralls (FBC), (3) self-made alternative PPEs (SMP), and (4) non-surgical isolation gowns (NSIG). An invisible tracer was sprayed on the gown after donning each subject. After doffing, each HCW was photographed under UV lights to show areas of fluorescent "contamination" on their clothes. The number, size, and intensity level of contaminated areas were noted, as well as observational deviation from the procedure and doffing time. In addition, the subjects were asked to take a questionnaire about their perception of the level of comfort, ease of doffing, and overall safety for each gown. Results Despite a well-trained team of HCW subjects, contamination while doffing was observed with every type of PPE gown, and with each HCW subject. All body areas were contaminated at least once, except the face. Contamination was more frequent while doffing FBCs. On the other hand, the removal of SG was found to be the least contaminating. The mean doffing time was significantly shorter with SG 1:29 and longer with FBC 2:26 (p=0.005). Conclusion Results of this study converge towards the selection of surgical gowns over other types of PPE gowns, which met both contamination criteria as well as staff appreciation in this context. Specific attention should be paid to the legs and abdomino-pelvic areas. Additional protection such as protective trousers or aprons could be added.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Determining Empirical Donning and Doffing Times for Complex Combinations of Personal Protective Equipment (PPE)
    Sims, LuAnn
    Davis, Gerard
    Sesek, Richard
    Gallagher, Sean
    Schall, Mark
    Bhardwaj, Prafful
    ADVANCES IN SAFETY MANAGEMENT AND HUMAN FACTORS, 2016, 491 : 89 - 100
  • [22] Modeling fomite-mediated SARS-CoV-2 exposure through personal protective equipment doffing in a hospital environment
    King, Marco-Felipe
    Wilson, Amanda M.
    Weir, Mark H.
    Lopez-Garcia, Martin
    Proctor, Jessica
    Hiwar, Waseem
    Khan, Amirul
    Fletcher, Louise A.
    Sleigh, P. Andrew
    Clifton, Ian
    Dancer, Stephanie J.
    Wilcox, Mark
    Reynolds, Kelly A.
    Noakes, Catherine J.
    INDOOR AIR, 2022, 32 (01)
  • [23] COVID-19 Personal Protective Equipment in the Home: Navigating the Complexity of Donning and Doffing
    Kerley, Brian
    Tan, Lana
    Marshall, Denise
    O'Neill, Cindy
    Bialachowski, Anne
    Pereira, Jose
    ANNALS OF FAMILY MEDICINE, 2021, 19 (05) : 405 - 410
  • [24] Out-of-hospital airway management: Knowledge and equipment
    Russo, S.
    Eich, C.
    Timmermann, A.
    ANAESTHESIA, PAIN, INTENSIVE CARE AND EMERGENCY: A.P.I.C.E., 2008, : 71 - +
  • [25] Reuse of Personal Protective Equipment: Results of a Human Factors Study Using Fluorescence to Identify Self-Contamination During Donning and Doffing
    Doos, Devin
    Barach, Paul
    Sarmiento, Elisa
    Ahmed, Rami
    JOURNAL OF EMERGENCY MEDICINE, 2022, 62 (03) : 337 - 341
  • [26] Contamination of personal protective equipment during COVID-19 autopsies
    Brandner, Johanna M.
    Boor, Peter
    Borcherding, Lukas
    Edler, Carolin
    Gerber, Sven
    Heinemann, Axel
    Hilsenbeck, Julia
    Kasajima, Atsuko
    Lohner, Larissa
    Maerkl, Bruno
    Pablik, Jessica
    Schroeder, Ann Sophie
    Slotta-Huspenina, Julia
    Sommer, Linna
    Sperhake, Jan-Peter
    von Stillfried, Saskia
    Dintner, Sebastian
    VIRCHOWS ARCHIV, 2022, 480 (03) : 519 - 528
  • [27] Environmental and Personal Protective Equipment Contamination during Simulated Healthcare Activities
    Weber, Rachel T.
    Phan, Linh T.
    Fritzen-Pedicini, Charissa
    Jones, Rachael M.
    ANNALS OF WORK EXPOSURES AND HEALTH, 2019, 63 (07) : 784 - 796
  • [28] Contamination of personal protective equipment during COVID-19 autopsies
    Johanna M. Brandner
    Peter Boor
    Lukas Borcherding
    Carolin Edler
    Sven Gerber
    Axel Heinemann
    Julia Hilsenbeck
    Atsuko Kasajima
    Larissa Lohner
    Bruno Märkl
    Jessica Pablik
    Ann Sophie Schröder
    Julia Slotta-Huspenina
    Linna Sommer
    Jan-Peter Sperhake
    Saskia von Stillfried
    Sebastian Dintner
    Virchows Archiv, 2022, 480 : 519 - 528
  • [29] Common Behaviors and Faults When Doffing Personal Protective Equipment for Patients With Serious Communicable Diseases
    Mumma, Joel M.
    Durso, Francis T.
    Casanova, Lisa M.
    Erukunuakpor, Kimberly
    Kraft, Colleen S.
    Ray, Susan M.
    Shane, Andi L.
    Walsh, Victoria L.
    Shah, Puja Y.
    Zimring, Craig
    DuBose, Jennifer
    Jacob, Jesse T.
    CLINICAL INFECTIOUS DISEASES, 2019, 69 : S214 - S220
  • [30] Personal protective equipment wearing in the context of COVID-19 in a hospital in Burkina Faso
    Dori, Daniel
    Tapsoba, Inoussa
    Sombie, Charles Bavouma
    Zime-Diawara, Hermine
    Ouedraogo, Moussa
    Semde, Rasmane
    Ye-Ouattara, Diarra
    Ouedraogo-Traore, Rasmata
    SANTE PUBLIQUE, 2022, 34 (06): : 837 - 846