Immediate Loading of Two Implants Supporting a Magnet Attachment-Retained Overdenture: One-Year Clinical Study

被引:20
|
作者
Pae, Ahran [1 ]
Kim, Jang-Wook [1 ]
Kwon, Kung-Rock [1 ]
机构
[1] Kyung Hee Univ, Sch Dent, Dept Prosthodont, Seoul 130701, South Korea
关键词
implant-retained mandibular overdentures; magnet attachments; immediate loading; STABILITY; SUCCESS;
D O I
10.1097/ID.0b013e3181f56deb
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this 1-year evaluation was to assess the stability of implants and the responses of the supporting tissues to magnet-retained mandibular implant overdentures. Methods: Six patients with completely edentulism were enrolled in this study. Each patient received 2 implants with sandblasted with large-grit and acid-etched surfaces in the interforaminal region. The implants were loaded immediately with magnet attachment-retained overdentures. The stability of the implants and periimplant tissues was examined by performing clinical examinations, resonance frequency analysis, and radiographic examinations at 1, 2, 6, 12, and 24 weeks and 1 year after surgery. Results: Two implants in 2 patients failed. The surviving implants were clinically and radiographically stable. The mean Implant Stability Quotient values were relatively stable, showing no significant differences (P > 0.05). The crestal bone changes were -1.18 +/- 0.68 mm, -1.35 +/- 0.69 mm, -1.47 +/- 0.68 mm, and -1.51 +/- 0.74 mm at the follow-up check performed at 6, 12, and 24 weeks and 1 year, respectively. The bleeding on probing index was not significant. Conclusions: The immediate loading of 2 implants using magnet attachment-retained mandibular overdentures may be a viable treatment option in cases of complete arch edentulism. This clinical approach offers increased stability to conventional dentures. (Implant Dent 2010;19:428-436)
引用
收藏
页码:428 / 436
页数:9
相关论文
共 47 条
  • [31] Immediate loading of two flapless placed mandibular implants supporting cross-arch fixed prostheses: A 5-year follow-up prospective single cohort study
    Cannizzaro, Gioacchino
    Felice, Pietro
    Lazzarini, Matteo
    Ferri, Vittorio
    Leone, Michele
    Trullenque-Eriksson, Anna
    Esposito, Marco
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2016, 9 (02) : 165 - 177
  • [32] Immediate loading of two flapless placed mandibular implants supporting cross-arch fixed prostheses: A 3-year follow-up prospective single cohort study
    Cannizzaro, Gioacchino
    Felice, Pietro
    Boveri, Muriel
    Lazzarini, Matteo
    Ferri, Vittorio
    Leone, Michele
    Esposito, Marco
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2014, 7 (01) : 89 - 98
  • [33] Immediate and early loading of hydrothermally treated, hydroxyapatite-coated dental implants: a 7-year prospective randomized clinical study
    Arghami, Afarin
    Simmons, David
    St Germain, Jeanne
    Maney, Pooja
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2021, 7 (01)
  • [34] Immediate loading of multiple splinted implants via complete digital workflow: A pilot clinical study with 1-year follow-up
    Jiang, Xi
    Lin, Ye
    Cui, Hong Y.
    Di, Ping
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (03) : 446 - 453
  • [35] Immediate and Early Loading of Hydrothermally Treated, Hydroxyapatite-Coated Dental Implants: 2-Year Results from a Prospective Clinical Study
    Simmons, David E.
    Palaiologou, Archontia
    Teitelbaum, Austin G.
    Billiot, Susan
    Popat, Lomesh J.
    Maney, Pooja
    JOURNAL OF ORAL IMPLANTOLOGY, 2016, 42 (01) : 17 - 25
  • [36] Immediate occlusal loading of Branemark System® TiUnite™ implants placed predominantly in soft bone:: 4-year results of a prospective clinical study
    Glauser, R
    Ruhstaller, P
    Windisch, S
    Zembic, A
    Lundgren, A
    Gottlow, J
    Hämmerle, CHF
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2005, 7 : S52 - S59
  • [37] Immediate Loading of Two Dental Implants, in Edentulous Mandibles, with Locator® Attachments or Dolder® Bars: First Results from a Prospective Randomized Clinical Study
    Kappel, Stefanie
    Eberhard, Lydia
    Giannakopoulos, Nikolaos Nikitas
    Rammelsberg, Peter
    Eiffler, Constantin
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 (04) : 629 - 638
  • [38] New-Design Dental Implants: A 1-Year Prospective Clinical Study of 344 Consecutively Placed Implants Comparing Immediate Loading Versus Delayed Loading and Flapless Versus Full-Thickness Flap
    Meizi, Eliezer
    Meir, Mamraev
    Laster, Zvi
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (01) : E14 - E21
  • [39] HARD AND SOFT TISSUE CHANGES IN THE REHABILITATION OF THE ANTERIOR MAXILLA WITH TRIANGULAR SHAPE NECK IMPLANTS: A RETROSPECTIVE CLINICAL STUDY WITH A ONE-YEAR FOLLOW UP
    D'Avenia, F.
    Del Fabbro, M.
    Karanxha, L.
    Weinstein, T.
    Corbella, S.
    Fumagalli, D.
    Francetti, L.
    Taschieri, S.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2019, 33 (06) : 13 - 21
  • [40] Direct loading of Nobel Direct® and Nobel Perfect® one-piece implants:: a 1-year prospective clinical and radiographic study
    Ostman, Per-Olov
    Hellman, Mats
    Albrektsson, Tomas
    Sennerby, Lars
    CLINICAL ORAL IMPLANTS RESEARCH, 2007, 18 (04) : 409 - 418