Measurement of the single-shot pulse energy of a free electron laser using a cryogenic radiometer

被引:11
作者
Kato, Masahiro [1 ,2 ]
Saito, Norio [1 ,2 ]
Tiedtke, Kai [2 ,3 ]
Juranic, Pavle N. [2 ,3 ]
Sorokin, Andrey A. [2 ,3 ,4 ]
Richter, Mathias [2 ,5 ]
Morishita, Yuichiro [1 ]
Tanaka, Takahiro [1 ,2 ]
Jastrow, Ulf [3 ]
Kroth, Udo [5 ]
Schoeppe, Hendrik [5 ]
Nagasono, Mitsuru [2 ]
Yabashi, Makina [2 ]
Tono, Kensuke [2 ]
Togashi, Tadashi [2 ,6 ]
Kimura, Hiroaki [6 ]
Ohashi, Haruhiko [6 ]
Ishikawa, Tetsuya [2 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, NMIJ, Tsukuba, Ibaraki 3058568, Japan
[2] RIKEN, XFEL Project Head Off, Sayo, Hyogo 6795148, Japan
[3] DESY, D-22603 Hamburg, Germany
[4] AF Ioffe Phys Tech Inst, St Petersburg 194021, Russia
[5] PTB, D-10587 Berlin, Germany
[6] Japan Synchrotron Radiat Res Inst, Sayo, Hyogo 6795198, Japan
关键词
EXTREME-ULTRAVIOLET; SYNCHROTRON-RADIATION; RADIANT POWER; PTB; STANDARD; VACUUM;
D O I
10.1088/0026-1394/47/5/002
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The absolute single-shot pulse energy of the SPring 8 extreme ultraviolet (EUV) free electron laser (FEL) was measured using a cryogenic radiometer with a relative standard uncertainty of 3%. The temperature change of the cavity in the cryogenic radiometer caused by an incident FEL pulse was determined using a lock-in amplifier and an ac Wheatstone bridge. The measured pulse energies were compared with a gas-monitor detector developed by Physikalisch-Technische Bundesanstalt/Deutsches Elektronen-Synchrotron/Ioffe Physico-Technical Institute (Ioffe) at a wavelength of 51.3 nm at the SPring-8 EUV-FEL in a shot-to-shot mode. The pulse energies measured using the two detectors agree within 2.0%.
引用
收藏
页码:518 / 521
页数:4
相关论文
共 18 条
[1]   A quarter-century of metrology using synchrotron radiation by PTB in Berlin [J].
Beckhoff, Burkhard ;
Gottwald, Alexander ;
Klein, Roman ;
Krumrey, Michael ;
Mueller, Ralph ;
Richter, Mathias ;
Scholze, Frank ;
Thornagel, Reiner ;
Ulm, Gerhard .
PHYSICA STATUS SOLIDI B-BASIC SOLID STATE PHYSICS, 2009, 246 (07) :1415-1434
[2]   X-ray free-electron lasers [J].
Feldhaus, J ;
Arthur, J ;
Hastings, JB .
JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 2005, 38 (09) :S799-S819
[3]   The PTB high-accuracy spectral responsivity scale in the VUV and x-ray range [J].
Gottwald, A. ;
Kroth, U. ;
Krumrey, M. ;
Richter, M. ;
Scholze, F. ;
Ulm, G. .
METROLOGIA, 2006, 43 (02) :S125-S129
[4]  
ICHINO Y, 2003, P 25 SESS CIE SAN DI, V25, pD2
[5]   Development of the soft X-ray intensity measurement with a cryogenic radiometer [J].
Kato, M. ;
Nohtomi, A. ;
Morishita, Y. ;
Kurosawa, T. ;
Arai, N. ;
Suzuki, I. H. ;
Saito, N. .
SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 :1129-+
[6]   Pulse energy of the extreme-ultraviolet free-electron laser at SPring-8 determined using a cryogenic radiometer [J].
Kato, M. ;
Saito, N. ;
Tanaka, T. ;
Morishita, Y. ;
Kimura, H. ;
Ohashi, H. ;
Nagasono, M. ;
Yabashi, M. ;
Tono, K. ;
Togashi, T. ;
Higashiya, A. ;
Ishikawa, T. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 612 (01) :209-211
[7]   Vacuum-compatible pulse selector for free-electron laser [J].
Kudo, Togo ;
Hirono, Toko ;
Nagasono, Mitsuru ;
Yabashi, Makina .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (09)
[8]   SCREENING FOR NEUROPEPTIDE-METABOLIZING PEPTIDASES DURING THE DIFFERENTIATION OF CHICK-EMBRYO RETINA [J].
MARTINS, AR ;
DEMELLO, FG .
DEVELOPMENTAL BRAIN RESEARCH, 1985, 21 (01) :147-151
[9]   Focusing multiple high-order harmonics in the extreme-ultraviolet and soft-x-ray regions by a platinum-coated ellipsoidal mirror [J].
Mashiko, H ;
Suda, A ;
Midorikawa, K .
APPLIED OPTICS, 2006, 45 (03) :573-577
[10]   Synchrotron-radiation-operated cryogenic electrical-substitution radiometer as the high-accuracy primary detector standard in the ultraviolet, vacuum-ultraviolet, and soft-x-ray spectral ranges [J].
Rabus, H ;
Persch, V ;
Ulm, G .
APPLIED OPTICS, 1997, 36 (22) :5421-5440