A double sided silicon strip detector as a DRAGON end detector

被引:13
作者
Wrede, C
Hussein, A
Rogers, JG
D'Auria, J
机构
[1] TRIUMF, SFU, Vancouver, BC V6T 2A3, Canada
[2] Simon Fraser Univ, Dept Phys, Burnaby, BC V5A 1S6, Canada
[3] Univ No British Columbia, Dept Phys, Prince George, BC V2L 5P2, Canada
关键词
D O I
10.1016/S0168-583X(02)02140-7
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The new DRAGON facility (detector of recoils and gammas of nuclear reactions), located at the TRIUMF-ISAC Radioactive Beams facility in Vancouver, Canada is now operational. This facility is used to study radiative proton capture reactions in inverse kinematics (heavy ion beam onto a light gaseous target) with both stable beams and radioactive beams of mass A = 13-26 in the energy range 0.15-1.5 MeV/u. A double sided silicon strip detector (DSSSD) has been used to detect recoil ions. Tests have been performed to determine the performance of this DSSSD. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:619 / 624
页数:6
相关论文
共 50 条
  • [21] SINGLE-SIDED STEREO ANGLE SILICON STRIP DETECTOR
    HUHTINEN, M
    ORAVA, R
    PIMIA, M
    TUUVA, T
    YLOSTALO, J
    OSTERBERG, K
    ERANEN, S
    LEINONEN, K
    HIETANEN, I
    TURCHETTA, R
    SCHAEFFER, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) : 335 - 338
  • [22] OPERATIONAL EXPERIENCE WITH A LARGE DETECTOR SYSTEM USING SILICON STRIP DETECTORS WITH DOUBLE SIDED READOUT
    BATIGNANI, G
    BAUER, C
    BECKER, H
    BLOCHDEVAUX, B
    BOUDREAU, J
    BROWN, D
    BOSI, F
    BOSISIO, L
    CARPINELLI, M
    CARR, J
    CATTANEO, P
    CIOCCI, A
    COYLE, P
    DELLORSO, R
    DIETL, H
    DRINKARD, J
    FOCARDI, E
    FORTI, F
    GIORGI, M
    HANSLKOZANECKA, T
    HAUFF, D
    HOLL, P
    JACOBSEN, RG
    LANCON, E
    LAUBER, J
    LITKE, A
    LUTZ, G
    LUTJENS, G
    MANNELLI, E
    MANNER, W
    MATTISON, T
    MCNEIL, M
    MENARY, S
    MONETA, L
    MOSER, HG
    MOURS, B
    OSSA, R
    PARRINI, G
    PICCININI, S
    REDLINGER, G
    RIZZI, D
    RIZZO, G
    ROOS, L
    ROUSSEAU, D
    TAYLOR, G
    TONELLI, G
    TRIGGIANI, G
    SCHWARZ, AS
    SCHWEMLING, P
    SETTLES, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 326 (1-2) : 183 - 188
  • [23] Characterization of an NTD Double-Sided Silicon Strip Detector Employing a Pulsed Proton Microbeam
    Duenas, J. A.
    Pasquali, G.
    Acosta, L.
    Parsani, T.
    Riccio, F.
    Carraresi, L.
    Taccetti, F.
    Castoldi, A.
    Guazzoni, C.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2017, 64 (09) : 2551 - 2560
  • [24] Beta-decay studies at the NSCL using a double-sided silicon strip detector
    Morton, AC
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY, 2003, 680 : 550 - 553
  • [25] Characterization of a NTD Double-Sided Silicon Strip Detector using a Pulsed Ion Beam
    Castoldi, A.
    Guazzoni, C.
    Parsani, T.
    Riccio, F.
    Carraresi, L.
    Taccetti, F.
    Acosta, L.
    Martel, I.
    Duenas, J. A.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [26] Improvement of radiation hardness of double-sided silicon strip detector for Belle SVD upgrade
    Kaneko, J
    Aihara, H
    Alimonti, G
    Hazumi, A
    Ishino, H
    Li, Y
    Sumisawa, K
    Tajima, H
    Tanaka, J
    Taylor, G
    Yamamoto, H
    Yokoyama, A
    Varner, G
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (04) : 1593 - 1597
  • [27] Evaluation of 0.5 mm thick double-sided silicon strip detector for Compton telescope
    Yasuda, Hajimu
    Fukazawa, Yasushi
    Takeda, Shin'ichiro
    Watanabe, Shin
    Takahashi, Tadayuki
    Nakazawa, Kazuhiro
    Tajima, Hiroyasu
    Tanakad, Takaaki
    HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS IX, 2007, 6706
  • [28] Characterization of a double sided microstrip silicon wedge detector
    Catacchini, E
    NUCLEAR PHYSICS B, 1998, : 335 - 340
  • [29] Pulse shape discrimination at low energies with a double sided, small-pitch strip silicon detector
    Genolini, B.
    Le Crom, B.
    Assie, M.
    Duenas, J. A.
    Mengoni, D.
    Ancelin, S.
    Beaumel, D.
    Blumenfeld, Y.
    Chabot, M.
    de Sereville, N.
    Faul, T.
    Guillot, J.
    Hammache, F.
    Jallat, A.
    Le Ven, V.
    Martel, I.
    Rauly, E.
    Suzuki, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 732 : 87 - 90
  • [30] Utilization of Double-Sided Silicon Strip Detectors within the PANDA Micro-Vertex-Detector
    Wuerschig, Thomas
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 1490 - 1494