Comparison of in vitro eye irritation potential by bovine corneal opacity and permeability (BCOP) assay to erythema scores in human eye sting test of surfactant-based formulations

被引:11
|
作者
Cater, Kathleen C. [2 ]
Harbell, John W. [1 ]
机构
[1] Mary Kay Inc, Addison, TX 75001 USA
[2] Dial Corp, Scottsdale, AZ USA
关键词
BCOP; human eye sting; Surfactants; eye irritation;
D O I
10.1080/15569520801914381
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The bovine corneal opacity and permeability (BCOP) assay can be used to predict relative eye irritation potential of surfactant-based personal care formulations relative to a corporate benchmark. The human eye sting test is typically used to evaluate product claims of no tears/no stinging for children's bath products. A preliminary investigation was conducted to test a hypothesis that the BCOP assay could be used as a prediction model for relative ranking of human eye irritation responses under conditions of a standard human eye sting test to surfactant-based formulations. BCOP assays and human eye sting tests were conducted on 4 commercial and 1 prototype body wash (BW) developed specifically for children or as mild bath products. In the human eye sting test, 10 l of a 10% dosing solution is instilled into one eye of each panelist (n = 20), and the contralateral eye is dosed with sterile water as a control. Bulbar conjunctival erythema responses of each eye are graded at 30 seconds by an ophthalmologist. The BCOP assay permeability values (optical density at 490nm [OD490]) for the 5 BWs ranged from 0.438 to 1.252 (i.e., least to most irritating). By comparison, the number of panelists exhibiting erythema responses (mild to moderately pink) ranged from 3 of 20 panelists for the least irritating BW to 10 of 20 panelists for the most irritating BW tested. The relative ranking of eye irritation potential of the 5 BWs in the BCOP assay compares favorably with the relative ranking of the BWs in the human eye sting test. Based on these findings, the permeability endpoint of the BCOP assay, as described for surfactant-based formulations, showed promise as a prediction model for relative ranking of conjunctival erythema responses in the human eye. Consequently, screening of prototype formulations in the BCOP assay would allow for formula optimization of mild bath products prior to investment in a human eye sting test.
引用
收藏
页码:77 / 85
页数:9
相关论文
共 11 条
  • [1] Prediction of eye irritation potential of surfactant-based rinse-off personal care formulations by the bovine corneal opacity and permeability (BCOP) assay
    Cater, Kathleen C.
    Harbell, John W.
    CUTANEOUS AND OCULAR TOXICOLOGY, 2006, 25 (03) : 217 - 233
  • [2] Improvement of the Bovine Corneal Opacity and Permeability (BCOP) assay as an in vitro alternative to the Draize rabbit eye irritation test
    Verstraelen, Sandra
    Jacobs, An
    De Wever, Bart
    Vanparys, Philippe
    TOXICOLOGY IN VITRO, 2013, 27 (04) : 1298 - 1311
  • [3] Eye irritation testing of nanomaterials using the EpiOcular™ eye irritation test and the bovine corneal opacity and permeability assay
    Susanne N. Kolle
    Ursula G. Sauer
    Maria C. Rey Moreno
    Wera Teubner
    Wendel Wohlleben
    Robert Landsiedel
    Particle and Fibre Toxicology, 13
  • [4] Eye irritation testing of nanomaterials using the EpiOcular™ eye irritation test and the bovine corneal opacity and permeability assay
    Kolle, Susanne N.
    Sauer, Ursula G.
    Moreno, Maria C. Rey
    Teubner, Wera
    Wohlleben, Wendel
    Landsiedel, Robert
    PARTICLE AND FIBRE TOXICOLOGY, 2016, 13
  • [5] A tiered approach combining the short time exposure (STE) test and the bovine corneal opacity and permeability (BCOP) assay for predicting eye irritation potential of chemicals
    Hayashi, Kazuhiko
    Mori, Taeko
    Abo, Takayuki
    Koike, Mirei
    Takahashi, Yutaka
    Sakaguchi, Hitoshi
    Nishiyama, Naohiro
    JOURNAL OF TOXICOLOGICAL SCIENCES, 2012, 37 (02) : 269 - 280
  • [6] A comparison of low volume, Draize and in vitro eye irritation test data.: III.: Surfactant-based formulations
    Gettings, SD
    Lordo, RA
    Feder, PI
    Hintze, KL
    FOOD AND CHEMICAL TOXICOLOGY, 1998, 36 (03) : 209 - 231
  • [7] In-house Validation of the EpiOcular™ Eye Irritation Test and its Combination with the Bovine Corneal Opacity and Permeability Test for the Assessment of Ocular Irritation
    Kolle, Susanne N.
    Kandarova, Helena
    Wareing, Britta
    van Ravenzwaay, Bennard
    Landsiedel, Robert
    ATLA-ALTERNATIVES TO LABORATORY ANIMALS, 2011, 39 (04): : 365 - 387
  • [8] Evaluation of eye irritation potential of experimental cosmetic formulations containing glycolic acid, salicylic acid and ethanol using the Bovine Corneal Opacity and Permeability Assay
    Labib, R.
    Cantrell, K.
    Costin, G. -E.
    Milac, A. L.
    Raabe, H.
    Gettings, S.
    CUTANEOUS AND OCULAR TOXICOLOGY, 2024, 43 (03) : 167 - 175
  • [9] Laser Light-Based Opacitometer 'Peira LLBO 180': A new and validated opacitometer for use in the Bovine Corneal Opacity and Permeability (BCOP) eye irritation test method
    Van Rompay, An R.
    Adriaens, Els
    Verstraelen, Sandra
    METHODSX, 2020, 7
  • [10] Short Time Exposure (STE) test in conjunction with Bovine Corneal Opacity and Permeability (BCOP) assay including histopathology to evaluate correspondence with the Globally Harmonized System (GHS) eye irritation classification of textile dyes
    Rodrigues Oliveira, Gisele Augusto
    Ducas, Rafael do Nascimento
    Teixeira, Gabriel Campos
    Batista, Aline Carvalho
    Oliveira, Danielle Palma
    Valadares, Marize Campos
    TOXICOLOGY IN VITRO, 2015, 29 (06) : 1283 - 1288