Determination of three estrogens and bisphenol A by functional ionic liquid dispersive liquid-phase microextraction coupled with ultra-high performance liquid chromatography and ultraviolet detection

被引:30
作者
Jiang, Yuehuang [1 ]
Tang, Tingting [1 ]
Cao, Zhen [1 ]
Shi, Guoyue [2 ]
Zhou, Tianshu [1 ]
机构
[1] E China Normal Univ, Sch Ecol & Environm Sci, Shanghai 200241, Peoples R China
[2] E China Normal Univ, Dept Chem, Shanghai 200241, Peoples R China
基金
中国国家自然科学基金;
关键词
Dispersive liquid-phase microextraction; Endocrine disruptors; Ionic liquids; Ultra-high performance liquid chromatography; ENDOCRINE-DISRUPTING CHEMICALS; STEROID SEX-HORMONES; WATER SAMPLES; EXTRACTION; CAPILLARY; DENSITY; CE;
D O I
10.1002/jssc.201401345
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A hydroxyl-functionalized ionic liquid, 1-hydroxyethyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide, was employed in an improved dispersive liquid-phase microextraction method coupled with ultra high performance liquid chromatography for the enrichment and determination of three estrogens and bisphenol A in environmental water samples. The introduced hydroxyl group acted as the H-bond acceptor that dispersed the ionic liquid effectively in the aqueous phase without dispersive solvent or external force. Fourier transform infrared spectroscopy indicated that the hydroxyl group of the cation of the ionic liquid enhanced the combination of extractant and analytes through the formation of hydrogen bonds. The improvement of the extraction efficiency compared with that with the use of alkyl ionic liquid was proved by a comparison study. The main parameters including volume of extractant, temperature, pH, and extraction time were investigated. The calibration curves were linear in the range of 5.0-1000 [mu g/L for estrone, estradiol, and bisphenol A, and 10.0-1000 mu g/L for estriol. The detection limits were in the range of 1.7-3.4 mu g/L. The extraction efficiency was evaluated by enrichment factor that were between 85 and 129. The proposed method was proved to be simple, low cost, and environmentally friendly for the determination of the four endocrine disruptors in environmental water samples.
引用
收藏
页码:2158 / 2166
页数:9
相关论文
共 41 条
  • [1] Competing hydrogen-bond donors: phenols vs. cyanooximes
    Aakeroy, Christer B.
    Epa, Kanishka N.
    Forbes, Safiyyah
    Desper, John
    [J]. CRYSTENGCOMM, 2013, 15 (30): : 5946 - 5949
  • [2] Hydroxyalkyl-Containing Imidazolium Homopolymers: Correlation of Structure with Conductivity
    Allen, Michael H., Jr.
    Wang, Sharon
    Hemp, Sean T.
    Chen, Ying
    Madsen, Louis A.
    Winey, Karen I.
    Long, Timothy E.
    [J]. MACROMOLECULES, 2013, 46 (08) : 3037 - 3045
  • [3] Determination of steroid sex hormones in water and urine matrices by stir bar sorptive extraction and liquid chromatography with diode array detection
    Almeida, C.
    Nogueira, J. M. F.
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (04) : 1303 - 1311
  • [4] Determination of steroid hormones in biological and environmental samples using green rnicroextraction techniques: An overview
    Aufartova, Jana
    Mahugo-Santana, Cristina
    Sosa-Ferrera, Zoraida
    Juan Santana-Rodriguez, Jose
    Novakova, Lucie
    Solich, Petr
    [J]. ANALYTICA CHIMICA ACTA, 2011, 704 (1-2) : 33 - 46
  • [5] Sample preparation method for the analysis of some organophosphorus pesticides residues in tomato by ultrasound-assisted solvent extraction followed by dispersive liquid-liquid microextraction
    Bidari, Araz
    Ganjali, Mohammad Reza
    Norouzi, Parviz
    Hosseini, Mohammad Reza Milani
    Assadi, Yaghoub
    [J]. FOOD CHEMISTRY, 2011, 126 (04) : 1840 - 1844
  • [6] Cammarata L, 2001, PHYS CHEM CHEM PHYS, V3, P5192, DOI 10.1039/b106900d
  • [7] Determination of the Migration of Bisphenol A from Polycarbonate by Dispersive Liquid-Liquid Microextraction Combined with High Performance Liquid Chromatography
    Cao, Jiangping
    Liu, Shuhui
    Bai, Weiwei
    Chen, Jie
    Xie, Qilong
    [J]. ANALYTICAL LETTERS, 2013, 46 (09) : 1342 - 1354
  • [8] Determination of the steroid hormone levels in water samples by dispersive liquid-liquid microextraction with solidification of a floating organic drop followed by high-performance liquid chromatography
    Chang, Chu-Chi
    Huang, Shang-Da
    [J]. ANALYTICA CHIMICA ACTA, 2010, 662 (01) : 39 - 43
  • [9] Chang H. C., 2008, J CHEM PHYS, V129, P1
  • [10] DEVELOPMENTAL EFFECTS OF ENDOCRINE-DISRUPTING CHEMICALS IN WILDLIFE AND HUMANS
    COLBORN, T
    SAAL, FSV
    SOTO, AM
    [J]. ENVIRONMENTAL HEALTH PERSPECTIVES, 1993, 101 (05) : 378 - 384