Computational study of the air flow dynamics in an induced draft cooling tower

被引:5
|
作者
Velandia, Juan S. [1 ]
Chery, Marie [2 ]
Lopez, Omar D. [1 ]
机构
[1] Univ Los Andes, Dept Mech Engn, Cra 1 Este 19A-40, Bogota, Colombia
[2] Edospina, Cra 7 24-89, Bogota, Colombia
关键词
Computational fluid dynamics; Cooling tower; Air flow dynamics; Porous media modeling; CFD;
D O I
10.1007/s40430-015-0348-y
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Cooling towers are one of the main solutions to reduce the water temperature used in industrial facilities. The air flow dynamics inside these devices is of especial interest, since it determines important operational variables such as power consumption. The present paper focuses on the air flow dynamics of two different geometrical configurations of induced draft cooling towers: a squared transverse area (referred as "FV25") and a circular transverse area (referred as "FV25c"). The complexity of the flow in some elements of the cooling tower such as the filmic fill and the drift eliminator was simplified by modeling them as porous media. The numerical parameters of the porous media models for these zones were based on detailed simulations of both elements in a wind tunnel-like configuration. Comparison of both configurations of the towers was made in terms of velocity and pressure contours, pressure drop and power consumption. It was found that the power used by the FV25c tower was only 60 % of the power used by the previous FV25 model due to complexity on the flow interaction and sudden transverse section changes. Computational fluid dynamics has proven to be a useful tool for the design process of cooling towers in the Colombian industry, as it allows understanding details of the air flow dynamics inside the cooling tower.
引用
收藏
页码:2393 / 2401
页数:9
相关论文
共 50 条
  • [31] Solar Tower Enhanced Natural Draft Dry Cooling Tower
    Yang, Huiqiang
    Xu, Yan
    Acosta-Iborra, Alberto
    Santana, Domingo
    INTERNATIONAL CONFERENCE ON CONCENTRATING SOLAR POWER AND CHEMICAL ENERGY SYSTEMS (SOLARPACES 2016), 2017, 1850
  • [32] A Study of the Mechanical Draft Heating/Cooling Tower Heat Pump System
    Luo, Yi
    Ma, Rongsheng
    Ding, Xingfeng
    Wang, Zhilin
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 702 - 707
  • [33] Numerical study on performance of hybrid mechanical draft wet cooling tower
    Deng, Weipeng
    Sun, Fengzhong
    Chen, Kun
    Zhang, Xiaoyu
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2023, 201
  • [34] Natural draft dry cooling tower modelling
    K. Tanimizu
    K. Hooman
    Heat and Mass Transfer, 2013, 49 : 155 - 161
  • [35] The discussion on cooling optimization of natural draft wet cooling tower
    Ma, L. B.
    Ren, J. X.
    Li, F. Q.
    Zhang, L. J.
    Li, M. Q.
    2018 FIRST INTERNATIONAL CONFERENCE ON ENVIRONMENT PREVENTION AND POLLUTION CONTROL TECHNOLOGY (EPPCT 2018), 2018, 199
  • [36] Retrieval of Controlling Parameter in Induced Draft Cooling Tower Using Inverse Method
    Singla, Rohit K.
    Das, Ranjan
    PROCEEDINGS OF 2016 2ND INTERNATIONAL CONFERENCE ON CONTROL SCIENCE AND SYSTEMS ENGINEERING (ICCSSE), 2016, : 223 - 226
  • [37] Optimal Control of Induced Draft Cooling Tower using Mixed Integer Programming
    Ghawash, Faiq
    Hovd, Morten
    Schofield, Brad
    5TH IEEE CONFERENCE ON CONTROL TECHNOLOGY AND APPLICATIONS (IEEE CCTA 2021), 2021, : 214 - 219
  • [38] Natural draft dry cooling tower modelling
    Tanimizu, K.
    Hooman, K.
    HEAT AND MASS TRANSFER, 2013, 49 (02) : 155 - 161
  • [39] Capacity Control of Induced Draft Cooling Tower using Two Stage Optimization
    Ghawash, Faiq
    Hovd, Morten
    Schofield, Brad
    2021 25TH INTERNATIONAL CONFERENCE ON SYSTEM THEORY, CONTROL AND COMPUTING (ICSTCC), 2021, : 485 - 490
  • [40] MULTI PARAMETER ESTIMATION IN AN INDUCED DRAFT COOLING TOWER USING GENETIC ALGORITHM
    Singh, Kuljeet
    Das, Ranjan
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2016, VOL. 8, 2017,