High resolution Fourier synthesis hard X-ray imaging based on CdTe strip detectors

被引:2
|
作者
Miyawaki, R
Niko, H
Okada, Y
Kokubun, M
Makishima, K
Negoro, H
Kotoku, J
Terada, Y
Tanaka, T
Mitani, T
Nakazawa, K
Takahashi, T
Ohno, R
Funaki, M
Kuroda, Y
Genba, K
Onishi, M
机构
[1] Univ Tokyo, Dept Phys, Tokyo 113, Japan
[2] RIKEN, Saitama, Japan
[3] Nihon Univ, Dept Phys, Tokyo, Japan
[4] Tokyo Inst Technol, Dept Phys, Tokyo 152, Japan
[5] ISAS, JAXA, Kanagawa, Japan
[6] ACRORAD Co Ltd, Okinawa, Japan
[7] Mitsubishi Heavy Ind Co Ltd, Aichi, Japan
关键词
CdTe; Fourier transforms; microstrip; X-ray astronomy detectors; X-ray imaging;
D O I
10.1109/TNS.2005.856885
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Employing Fourier-synthesis optics and one-dimensional position-sensitive detectors, we are developing a novel hard X-ray imager which can work in the similar to 10 keV to similar to 200 keV range either as a telescope or a microscope. As the detection part of our imager, we have developed a strip detector made of Schottky CdTe diode, with its cathode divided into 64 channels of 150 mu m pitch. Electrodes of all channels are gold-stud bonded to a fanout board, and connected to low noise analog ASIC. We read out signals from all channels simultaneously. As the grid optics elements, one-dimensional "modulation collimator" grids of 1 mm thick tungsten have been manufactured, with 10 grid pitches ranging from 0.2 mm to 2 mm with harmonic ratios. Combining the CdTe strip detector and the grids, we have verified hard X-ray imaging performance of this system. Using an Am-241 source, we have successfully obtained an image in the 10-70 keV range with a spatial resolution of similar to 0.5 mm.
引用
收藏
页码:2052 / 2057
页数:6
相关论文
共 50 条
  • [1] High resolution Fourier synthesis hard X-ray imaging based on CdTe strip detectors
    Miyawaki, R
    Niko, H
    Okada, Y
    Kokubun, M
    Makishima, K
    Negoro, H
    Kotoku, J
    Terada, Y
    Tanaka, T
    Mitani, T
    Nakazawa, K
    Takahashi, T
    Ohno, R
    Funaki, M
    Kuroda, Y
    Genba, K
    Onishi, M
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4392 - 4396
  • [2] Wide-gap CdTe strip detectors for high-resolution imaging in hard X-rays
    Nagasawa, Shunsaku
    Minami, Takahiro
    Watanabe, Shin
    Takahashi, Tadayuki
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1050
  • [3] Characterization of Edgeless CdTe Detectors for use in Hard X-Ray Imaging Applications
    Veale, Matthew C.
    Bell, Steven J.
    Jones, Lawrence L.
    Seller, Paul
    Wilson, Matthew D.
    Cernik, Robert C.
    Kalliopuska, Juha
    Pohjonen, Harri
    Andersson, Hans
    Nenonen, Seppo
    Kachkanov, Vyacheslav
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (04) : 1536 - 1543
  • [4] Optimizing CdTe detectors and ASIC readouts for high-flux x-ray imaging
    Barber, William C.
    Nygard, Einar
    Wessel, Jan C.
    Malakhov, Nail
    Hartsough, Neal E.
    Gandhi, Thulasi
    Wawrzyniak, Gregor
    Iwanczyk, Jan S.
    MEDICAL APPLICATIONS OF RADIATION DETECTORS, 2011, 8143
  • [5] High-resolution Schottky CdTe diode for hard X-ray and gamma-ray astronomy
    Takahashi, T
    Paul, B
    Hirose, K
    Matsumoto, C
    Ohno, R
    Ozaki, T
    Mori, K
    Tomita, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2) : 111 - 119
  • [6] Photon counting X-ray imaging with CdTe pixel detectors based on XPAD2 circuit
    Franchi, Romain
    Glasser, Francis
    Gasse, Adrien
    Clemens, Jean-Claude
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (01) : 249 - 253
  • [7] Balloon-Borne Hard X-Ray Spectrometer Using CdTe Detectors
    K. Kobayashi
    S. Tsuneta
    T. Tamura
    K. Kumagai
    Y. Katsukawa
    M. Kubo
    Y. Sakamoto
    N. Kohara
    T. Yamagami
    Y. Saito
    K. Mori
    Solar Physics, 2008, 250 : 431 - 441
  • [8] Balloon-borne hard X-ray spectrometer using CdTe detectors
    Kobayashi, K.
    Tsuneta, S.
    Tamura, T.
    Kumagai, K.
    Katsukawa, Y.
    Kubo, M.
    Sakamoto, Y.
    Kohara, N.
    Yamagami, T.
    Saito, Y.
    Mori, K.
    SOLAR PHYSICS, 2008, 250 (02) : 431 - 441
  • [9] Screening effects in high resistivity CdTe for X-ray and gamma ray detectors
    Kubat, J.
    Franc, J.
    Grill, R.
    Horodysky, P.
    Hlidek, P.
    Belas, E.
    JOURNAL OF ELECTRONIC MATERIALS, 2007, 36 (08) : 871 - 876
  • [10] Screening Effects in High Resistivity CdTe for X-ray and Gamma Ray Detectors
    J. Kubát
    J. Franc
    R. Grill
    P. Horodyský
    P. Hlídek
    E. Belas
    Journal of Electronic Materials, 2007, 36 : 871 - 876