Elevation Changes of Central Posterior Corneal Surface After Intracorneal Ring Segment Implantation in Keratoconus

被引:22
作者
Sogutlu, Esin [1 ]
Pinero, David P. [2 ,3 ]
Kubaloglu, Anil [1 ]
Alio, Jorge L. [2 ,4 ]
Cinar, Yasin [1 ]
机构
[1] Kartal Training & Res Hosp, Istanbul, Turkey
[2] Vissum Inst Oftalmol Alicante, Keratoconus Unit, Alicante, Spain
[3] Univ Alicante, Dept Opt Farmacol & Anat, E-03080 Alicante, Spain
[4] Univ Miguel Hernandez, Div Ophthalmol, Alicante, Spain
关键词
keratoconus; intracorneal ring segments; KeraRing; posterior corneal surface; Pentacam; TERM-FOLLOW-UP; SCHEIMPFLUG PHOTOGRAPHY; FEMTOSECOND LASER; NORMAL EYES; REPEATABILITY; ANTERIOR; INTACS; PENTACAM; PERFORMANCE; TOPOGRAPHY;
D O I
10.1097/ICO.0b013e31822481df
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare changes that occur at the posterior corneal surface after the implantation of intracorneal ring segments (ICRSs) using either mechanical or femtosecond laser-assisted procedures and to correlate these changes with the visual outcome achieved. Methods: Retrospective, nonrandomized, and interventional case series including 223 consecutive eyes of 186 patients with keratoconus ranging in age from 16 to 39 years that were implanted with ring segments (KeraRing; Mediphacos) at Kartal Training and Research Hospital, Istanbul, Turkey. Two groups were created according to the surgical technique used: mechanical group (168 eyes) and femtosecond group (55 eyes). Visual and refractive outcomes and corneal elevation changes were evaluated during a 24-month follow-up. Correlations between visual and posterior elevation changes were evaluated. Results: The posterior corneal surface could not be analyzed with accuracy for diameters larger than the diameter of the ICRS implant. A statistically significant reduction of maximum elevation for both the corneal surfaces was observed at 1 month after the surgery (P < 0.01), with additional reductions at 3 and 6 months (P <= 0.03). In addition, the posterior best-fit sphere was flattened significantly at 1 month after the surgery in both the groups, with additional flattening at 3 months (P <= 0.03). No significant differences between groups in posterior corneal elevation parameters were found at any time point of the follow-up (P >= 0.14). Moderate and significant correlations of the postoperative visual outcome with the change in posterior best-fit sphere were found only in the femtosecond group. Conclusions: A central corneal flattening of the posterior corneal surface occurs after ring segment implantation in keratoconus.
引用
收藏
页码:387 / 395
页数:9
相关论文
共 31 条
[1]   Analysis of results related to good and bad outcomes of Intacs implantation for keratoconus correction [J].
Alió, JL ;
Shabayek, MH ;
Belda, JI ;
Correas, P ;
Feijoo, ED .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (05) :756-761
[2]   Intracorneal ring segments for keratoconus correction:: Long-term follow-up [J].
Alio, Jorge L. ;
Shabayek, Mohamed H. ;
Artola, Alberto .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (06) :978-985
[3]   Intracorneal rings to correct corneal ectasia after laser in situ keratomileusis [J].
Alió, L ;
Salem, TF ;
Artola, A ;
Osman, AA .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (09) :1568-1574
[4]   Keratoconus: It is hard to define, but ... [J].
Belin, Michael W. ;
Khachikian, Stephen S. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (03) :500-503
[5]   Intrasession and intersession repeatability of the Pentacam system on posterior corneal assessment in the normal human eye [J].
Chen, Davie ;
Lam, Andrew K. C. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (03) :448-454
[6]   Reliability and repeatability of the Pentacam on corneal curvatures [J].
Chen, Davie ;
Lam, Andrew K. C. .
CLINICAL AND EXPERIMENTAL OPTOMETRY, 2009, 92 (02) :110-118
[7]   Correcting keratoconus with intracorneal rings [J].
Colin, J ;
Cochener, B ;
Savary, G ;
Malet, F .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (08) :1117-1122
[8]   INTACS inserts for treating keratoconus - One-year results [J].
Colin, J ;
Cochener, B ;
Savary, G ;
Malet, F ;
Holmes-Higgin, D .
OPHTHALMOLOGY, 2001, 108 (08) :1409-1414
[9]   Intacs insertion with the femtosecond laser for the management of keratoconus - One-year results [J].
Ertan, Aylin ;
Kamburoglu, Gunhal ;
Bahadir, Mehmet .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (12) :2039-2042
[10]   Repeatability, reproducibility, and agreement characteristics of rotating Scheimpflug photography and scanning-slit corneal topography for corneal power measurement [J].
Kawamorita, Takushi ;
Uozato, Hiroshi ;
Kamiya, Kazutaka ;
Bax, Leon ;
Tsutsui, Kenta ;
Aizawa, Daisuke ;
Shimizu, Kimiya .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (01) :127-133