Inversion-recovery-prepared dixon bSSFP: Initial clinical experience with a novel pulse sequence for renal MRA within a breathhold

被引:7
作者
Worters, Pauline W. [1 ]
Saranathan, Manojkumar [1 ]
Xu, Alan [1 ]
Vasanawala, Shreyas S. [1 ]
机构
[1] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
关键词
non-contrast-enhanced; MR angiography; breathhold; renal; balanced SSFP; Dixon; ANGIOGRAPHY; ARTERIES; MOTION; ECHO; HOLD;
D O I
10.1002/jmri.23503
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the capability of a new breathhold noncontrast-enhanced MRA method (Non-contrast Outer Radial Inner Square k-space Scheme, NORISKS) to visualize renal arteries by comparing the method with a routine clinical but significantly longer noncontrast-enhanced (non-CE) MRA technique. Materials and Methods: Eighteen subjects referred for abdominal MRI were examined with NORISKS and a routine non-contrast-enhanced MRA technique. Two versions of NORISKS were evaluated: with and without ECG gating. The images were then scored independently and in blinded manner by two radiologists on 5-point scales for visualization of the proximal and distal renal arteries and quality of fat suppression. Results: No statistically significant difference was detected between NORISKS and routine clinical non-CE MRA in all categories except for visualization of the distal renal arteries where ungated NORISKS performed poorer than the routine non-CE MRA (P < 10(-4)). Conclusion: We have demonstrated a promising non-CE MRA method for acquiring renal angiograms within a breathhold without any compromise in spatial resolution or coverage. ECG-gated NORISKS is able to acquire renal angiograms that are comparable to a routine clinical non-CE MRA method (Inhance IFIR, GE Healthcare), which requires approximately seven times the scan time of NORISKS.
引用
收藏
页码:875 / 881
页数:7
相关论文
共 31 条
  • [1] Two-point Dixon Method With Flexible Echo Times
    Berglund, Johan
    Ahlstroem, Hakan
    Johansson, Lars
    Kullberg, Joel
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (04) : 994 - 1004
  • [2] Analysis and compensation of eddy currents in balanced SSFP
    Bieri, O
    Markl, M
    Scheffler, K
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (01) : 129 - 137
  • [3] Comparison of reconstruction accuracy and efficiency among autocalibrating data-driven parallel imaging methods
    Brau, Anja C. S.
    Beatty, Philip J.
    Skare, Stefan
    Bammer, Roland
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (02) : 382 - 395
  • [4] Coenegrachts KL, 2004, RADIOLOGY, V231, P237, DOI 10.1148/radioi.2311030044
  • [5] Dual-Echo Dixon Imaging with Flexible Choice of Echo Times
    Eggers, Holger
    Brendel, Bernhard
    Duijndam, Adri
    Herigault, Gwenael
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (01) : 96 - 107
  • [6] Non-Contrast Renal Artery MRA Using an Inflow Inversion Recovery Steady State Free Precession Technique (Inhance): Comparison with 3D Contrast-Enhanced MRA
    Glockner, James F.
    Takahashi, Naoki
    Kawashima, Akira
    Woodrum, David A.
    Stanley, David W.
    Takei, Naoyuki
    Miyoshi, Mitsuharu
    Sun, Wei
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (06) : 1411 - 1418
  • [7] Renal arteries: Comparison of steady-state free precession MR angiography and contrast-enhanced MR angiography
    Herborn, CU
    Watkins, DM
    Runge, VM
    Gendron, JM
    Montgomery, ML
    Naul, LG
    [J]. RADIOLOGY, 2006, 239 (01) : 263 - 268
  • [8] Diaphragmatic and cardiac motion during suspended breathing: Preliminary experience and implications for breath-hold MR imaging
    Holland, AE
    Goldfarb, JW
    Edelman, RR
    [J]. RADIOLOGY, 1998, 209 (02) : 483 - 489
  • [9] Kaandorp DW, 2000, J MAGN RESON IMAGING, V12, P924, DOI 10.1002/1522-2586(200012)12:6<924::AID-JMRI16>3.0.CO
  • [10] 2-0