Optical diagnosis of gastric cancer using near-infrared multichannel Raman spectroscopy with a 1064-nm excitation wavelength

被引:41
|
作者
Kawabata, Toshiki [1 ]
Mizuno, Toshihiko [2 ]
Okazaki, Shigetoshi [2 ]
Hiramatsu, Mitsuo [2 ]
Setoguchil, Tomohiko [1 ]
Kikuchi, Hirotoshi [1 ]
Yamamoto, Masayoshi [1 ]
Hiramatsu, Yoshihiro [1 ]
Kondo, Kenji [1 ]
Baba, Megumi [1 ]
Ohta, Manabu [1 ]
Kamiya, Kinji [1 ]
Tanaka, Tatsuo [1 ]
Suzuki, Shohachi [1 ]
Konno, Hiroyuki [1 ]
机构
[1] Hamamatsu Univ Sch Med, Dept Surg 2, Higashi Ku, Hamamatsu, Shizuoka 4313192, Japan
[2] Hamamatsu Photon KK, Shizuoka, Japan
关键词
gastric cancer; Raman spectroscopy; optical biopsy; endoscopy;
D O I
10.1007/s00535-008-2160-2
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background Gastric cancer is one of the most common cancers in Japan. The use of endoscopy is increasing, along with the number of histological examinations of specimens obtained by endoscopy. However, it takes several days to reach a diagnosis, which increases the medical expense. Raman spectroscopy is one of the available optical techniques, and the Raman spectrum for each molecule and tissue is characteristic and specific. The present study investigated whether Raman spectroscopy can be used to diagnose gastric cancer. Methods. A total of 251 fresh biopsy specimens of gastric carcinoma and non-neoplastic mucosa were obtained from 49 gastric cancer patients at endoscopy. Without any pretreatment, the fresh specimens were measured with a near-infrared multichannel Raman spectroscopic system with an excitation wavelength of 1064nm, and Raman spectra specific for the specimens were obtained. A principal component analysis (PCA) was performed to distinguish gastric cancer and nonneoplastic tissue, and a discriminant analysis was used to evaluate the accuracy of the gastric cancer diagnosis. Results. The Raman spectra for cancer specimens differed from those for non-neoplastic specimens, especially at around 1644 cm(-1). Sensitivity was 66 %, specificity was 73 %, and accuracy was 70 %. The accuracy of diagnosis using the single Raman scattering intensity at 1644cm(-1) was 70%, consistent with the PCA result. Conclusions. The present results indicate that near-infrared multichannel Raman spectroscopy with a 1064nm excitation wavelength is useful for gastric cancer diagnosis. Establishment of a Raman diagnostic system for gastric cancer may improve the clinical diagnosis of gastric cancer and be beneficial for patients.
引用
收藏
页码:283 / 290
页数:8
相关论文
共 50 条
  • [21] In vivo diagnosis of colonic precancer and cancer using near-infrared autofluorescence spectroscopy and biochemical modeling
    Shao, Xiaozhuo
    Zheng, Wei
    Huang, Zhiwei
    JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (06)
  • [22] Quantitative analysis of skin chemicals using rapid near-infrared Raman spectroscopy
    Zhao, Jianhua
    Huang, Zhwei
    Zeng, Haishan
    McLean, David I.
    Lui, Harvey
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS IV, 2008, 6842
  • [23] Optical imaging of gastric cancer with near-infrared heptamethine carbocyanine fluorescence dyes
    Zhao, Ningning
    Zhang, Caiqin
    Zhao, Yong
    Bai, Bing
    An, Jiaze
    Zhang, Hai
    Wu, Jason Boyang
    Shi, Changhong
    ONCOTARGET, 2016, 7 (35) : 57277 - 57289
  • [24] AQUEOUS DISSOLVED-GAS MEASUREMENTS USING NEAR-INFRARED RAMAN-SPECTROSCOPY
    BERGER, AJ
    WANG, Y
    SAMMETH, DM
    ITZKAN, I
    KNEIPP, K
    FELD, MS
    APPLIED SPECTROSCOPY, 1995, 49 (08) : 1164 - 1169
  • [25] Investigating dehydration from compacts using terahertz pulsed, Raman, and near-infrared spectroscopy
    Kogermann, Karin
    Zeitler, J. Axel
    Rantanen, Jukka
    Rades, Thomas
    Taday, Philip F.
    Pepper, Michael
    Heinamaki, Jyrki
    Strachan, Clare J.
    APPLIED SPECTROSCOPY, 2007, 61 (12) : 1265 - 1274
  • [26] Identification of Different Forms of Cocaine and Substances Used in Adulteration Using Near-infrared Raman Spectroscopy and Infrared Absorption Spectroscopy
    Penido, Ciro A. F. O.
    Pacheco, Marcos Tadeu T.
    Zangaro, Renato A.
    Silveira, Landulfo, Jr.
    JOURNAL OF FORENSIC SCIENCES, 2015, 60 (01) : 171 - 178
  • [27] Classification of colonic tissues using near-infrared Raman spectroscopy and support vector machines
    Widjaja, Effendi
    Zheng, Wei
    Huang, Zhiwei
    INTERNATIONAL JOURNAL OF ONCOLOGY, 2008, 32 (03) : 653 - 662
  • [28] Gastric cancer target detection using near-infrared hyperspectral imaging with chemometrics
    Yi, Weisong
    Zhang, Jian
    Jiang, Houmin
    Zhang, Niya
    TWELFTH INTERNATIONAL CONFERENCE ON PHOTONICS AND IMAGING IN BIOLOGY AND MEDICINE (PIBM 2014), 2014, 9230
  • [29] Shifted excitation Raman difference spectroscopy using a dual-wavelength DBR diode laser at 671 nm
    Maiwald, M.
    Fricke, J.
    Ginolas, A.
    Pohl, J.
    Sumpf, B.
    Erbert, G.
    Traenkle, G.
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC AND SURGICAL GUIDANCE SYSTEMS XII, 2014, 8935
  • [30] Shifted Excitation Raman Difference Spectroscopy using a Dual-Wavelength DBR Diode Laser at 785 nm
    Maiwald, M.
    Eppich, B.
    Fricke, J.
    Ginolas, A.
    Bugge, F.
    Klehr, A.
    Sumpf, B.
    Erbert, G.
    Traenkle, G.
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC AND SURGICAL GUIDANCE SYSTEMS XIII, 2015, 9313