Femoral bone blood flow after reaming and intramedullary canal preparation - A canine study using laser Doppler flowmetry

被引:10
|
作者
ElMaraghy, AW [1 ]
Humeniuk, B [1 ]
Anderson, GI [1 ]
Schemitsch, EH [1 ]
Richards, RR [1 ]
机构
[1] St Michaels Hosp, Dept Surg, Div Orthopaed Surg, Musculoskeletal Res Lab, Halifax, NS, Canada
基金
英国医学研究理事会;
关键词
laser Doppler flowmetry; bone blood flow; reaming; intramedullary canal preparation;
D O I
10.1016/S0883-5403(99)90130-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study was conducted to determine the effect of intramedullary reaming and canal preparation on bone blood now in the proximal femur. Thirty-five adult dogs were randomly assigned to have their intramedullary canals prepared after reaming in the following manner: group 1, ream only; group 2, lavage; group 3, methylmethacrylate cement introduction; group 4, cement pressurization after placing a cement restrictor; group 5, lavage then cement introduction; and group 6, lavage then cement pressurization. Bone blood now was measured at both metaphyseal and diaphyseal sites by using laser Doppler flowmetry before reaming, after reaming, after lavage, after cementing, and at 6 weeks after the procedure just before euthanasia. Reaming significantly decreased bone blood flow in the diaphysis (P =.046) but not in the metaphysis. Cement introduction and cement pressurization both significantly decreased bone blood now in the metaphysis (P =.035, P =.004) and diaphysis (P =.007, P =.029). Pressurization of cement had a significantly greater relative effect than cement introduction alone in the diaphysis (P =.006) but not in the metaphysis. Lavage had no effect on bone perfusion. Bone blood flow was significantly increased at 6 weeks after the initial procedure in both the metaphysis (P =.049) and the diaphysis (P =.004). The results suggest that reaming decreases diaphyseal cortical but not metaphyseal bone blood flow significantly, whereas lavage has no effect. Cement introduction with or without pressurization has a significant detrimental effect on metaphyseal and diaphyseal blood now. These findings have implications for intramedullary nailing and for canal preparation when performing arthroplasty.
引用
收藏
页码:220 / 226
页数:7
相关论文
共 39 条
  • [1] Femoral and cruciate blood flow after retrograde femoral reaming: A canine study using laser Doppler flowmetry
    ElMaraghy, AW
    Schemitsch, EH
    Richards, RR
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1998, 12 (04) : 253 - 258
  • [2] Changes in Femoral Cortical Porosity After Reaming and Intramedullary Canal Preparation in a Canine Model
    Syed, Khalid A.
    Kuzyk, Paul R. T.
    Yoo, Daniel J.
    Zdero, Rad
    Richards, Robin R.
    Schemitsch, Emil H.
    JOURNAL OF ARTHROPLASTY, 2013, 28 (02) : 368 - 373
  • [3] Evaluation of surface blood flow in intact and ruptured canine cruciate ligaments using laser Doppler flowmetry
    Testuz, Joakim
    Howard, Judith
    Pozzi, Antonio
    Rytz, Ulrich
    Krudewig, Christiane
    Spreng, David
    Forterre, Simone
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2016, 29 (05) : 361 - 368
  • [4] Ocular blood flow assessment using continuous laser Doppler flowmetry
    Riva, Charles E.
    Geiser, Martial
    Petrig, Benno L.
    ACTA OPHTHALMOLOGICA, 2010, 88 (06) : 622 - 629
  • [5] Evaluation of Cerebral Blood Flow Autoregulation in the Rat Using Laser Doppler Flowmetry
    Allen, Linda A.
    Terashvili, Maia
    Gifford, Alison
    Lombard, Julian H.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2020, (155):
  • [6] Evaluation of the effect of different desensitizers on pulpal blood flow after full crown preparation using laser Doppler flowmetry: a randomized clinical trial
    Zeliha Uğur-Aydın
    Hamiyet Kılınç
    Yasemin Akbaş
    Sıla Nur Usta
    Odontology, 2024, 112 : 272 - 278
  • [7] Evaluation of the effect of different desensitizers on pulpal blood flow after full crown preparation using laser Doppler flowmetry: a randomized clinical trial
    Ugur-Aydin, Zeliha
    Kilinc, Hamiyet
    Akbas, Yasemin
    Usta, Sila Nur
    ODONTOLOGY, 2024, 112 (01) : 272 - 278
  • [8] Does tropicamide affect choroidal blood flow in humans? A laser Doppler flowmetry study
    Palanisamy, Nithiyanantham
    Riva, Charles E.
    Rovati, Luigi
    Cellini, Mauro
    Gizzi, Corrado
    Strobbe, Ernesto
    Campos, Emilio C.
    OPHTHALMIC TECHNOLOGIES XXII, 2012, 8209
  • [9] Blood flow measurement in reconstructed anterior cruciate ligaments using laser Doppler flowmetry
    Yamagishi T.
    Fujii K.
    Roppongi S.
    Hatsuumi H.
    Knee Surgery, Sports Traumatology, Arthroscopy, 1998, 6 (3) : 160 - 164
  • [10] RAPID AUTOREGULATION OF CEREBRAL BLOOD-FLOW - A LASER-DOPPLER FLOWMETRY STUDY
    FLORENCE, G
    SEYLAZ, J
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1992, 12 (04) : 674 - 680