Subjective visual acuity with simulated defocus

被引:19
作者
Dehnert, Anne [1 ]
Bach, Michael [1 ]
Heinrich, Sven P. [1 ]
机构
[1] Univ Augenklin, Sekt Funkt Sehforsch, Freiburg, Germany
关键词
defocus; dioptric blur; Fourier-optical model; visual acuity;
D O I
10.1111/j.1475-1313.2011.00857.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: Artificial degradation of vision by inducing dioptric blur is frequently used for evaluating diagnostic equipment. However, the use of lenses is prone to errors as it is adversely affected by eyelid squinting, pupil size, and imprecise lens position. The alternative is a degradation of the stimuli themselves based on a Fourier-optical mathematical model. With this, however, perceptual effects such as 'simultaneous blur' induced by the surround may affect acuity. We tested whether both methods, lens induced defocus and mathematical stimulus degradation, yield concordant results. Methods: We compared both methods in normal subjects, measuring Landolt C acuity at five different levels of defocus from 0 to 8 dioptres. The pupil size was determined individually, chromatic aberrations were avoided by using a monochromatic approach, and a correction for spectacle magnification was included. Otherwise, the experimental design was kept deliberately simple to remain comparable to typical applications. Results: With the major sources of error associated with the use of lenses being accounted for, both methods yield similar mean results with differences in acuity ranging from <0.001 to 0.054 logMAR (0.2-13%). Conclusion: Using mathematically simulated defocus is a viable option if both reasonable accuracy and ease of use are required. The fact that the application of the mathematical model only blurs the stimulus itself, but not the surrounding environment, does not appear to be detrimental to the method.
引用
收藏
页码:625 / 631
页数:7
相关论文
共 22 条
[1]   The Freiburg Visual Acuity test - Automatic measurement of visual acuity [J].
Bach, M .
OPTOMETRY AND VISION SCIENCE, 1996, 73 (01) :49-53
[2]   Anti-aliasing and dithering in the 'Freiburg Visual Acuity Test' [J].
Bach, M .
SPATIAL VISION, 1997, 11 (01) :85-89
[3]  
BACH M, 1989, SEEING CONTOUR COLOR, P562
[4]  
CHAN C, 1985, AM J OPTOM PHYS OPT, V62, P207
[5]  
Chan Ho-Lung, 2003, Clin Exp Optom, V86, P317
[6]   A new source of variance in visual acuity [J].
Coppens, JE ;
van den Berg, TJTP .
VISION RESEARCH, 2004, 44 (09) :951-958
[7]   Experimental validation of a Bayesian model of visual acuity [J].
Dalimier, Eugenie ;
Pailos, Eliseo ;
Rivera, Ricardo ;
Navarro, Rafael .
JOURNAL OF VISION, 2009, 9 (07)
[8]  
Goersch H, 2000, HDB AUGENOPTIK
[9]   "Cognitive" visual acuity estimation based on the event-related potential P300 component [J].
Heinrich, Sven P. ;
Marhoefer, David ;
Bach, Michael .
CLINICAL NEUROPHYSIOLOGY, 2010, 121 (09) :1464-1472
[10]   Accommodation limits induced optical defocus in defocus experiments [J].
Jaegle, Herbert ;
Zobor, Ditta ;
Brauns, Thomas .
DOCUMENTA OPHTHALMOLOGICA, 2010, 121 (02) :103-109