Full-Scale Fatigue Testing of a Wind Turbine Blade in Flapwise Direction and Examining the Effect of Crack Propagation on the Blade Performance

被引:43
作者
Al-Khudairi, Othman [1 ]
Hadavinia, Homayoun [1 ]
Little, Christian [2 ]
Gillmore, Gavin [1 ]
Greaves, Peter [2 ]
Dyer, Kirsten [2 ]
机构
[1] Kingston Univ, Sch Engn, London SW15 3DW, England
[2] Offshore Renewable Energy Catapult ORE, Blyth NE24 1LZ, England
关键词
wind turbine; wind blades; flapwise fatigue test; blade modal testing; glass fibre polymer composite; STRUCTURAL COLLAPSE; FRACTURE-TOUGHNESS;
D O I
10.3390/ma10101152
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In this paper, the sensitivity of the structural integrity of wind turbine blades to debonding of the shear web from the spar cap was investigated. In this regard, modal analysis, static and fatigue testing were performed on a 45.7 m blade for three states of the blade: (i) as received blade (ii) when a crack of 200 mm was introduced between the web and the spar cap and (iii) when the crack was extended to 1000 mm. Calibration pull-tests for all three states of the blade were performed to obtain the strain-bending moment relationship of the blade according to the estimated target bending moment (BM) which the blade is expected to experience in its service life. The resultant data was used to apply appropriate load in the fatigue tests. The blade natural frequencies in flapwise and edgewise directions over a range of frequency domain were found by modal testing for all three states of the blade. The blade first natural frequency for each state was used for the flapwise fatigue tests. These were performed in accordance with technical specification IEC TS 61400-23. The fatigue results showed that, for a 200 mm crack between the web and spar cap at 9 m from the blade root, the crack did not propagate at 50% of the target BM up to 62,110 cycles. However, when the load was increased to 70% of target BM, some damages were detected on the pressure side of the blade. When the 200 mm crack was extended to 1000 mm, the crack began to propagate when the applied load exceeded 100% of target BM and the blade experienced delaminations, adhesive joint failure, compression failure and sandwich core failure.
引用
收藏
页数:22
相关论文
共 24 条
[1]   Characterising mode I/mode II fatigue delamination growth in unidirectional fibre reinforced polymer laminates [J].
Al-Khudairi, O. ;
Hadavinia, H. ;
Waggott, A. ;
Lewis, E. ;
Little, C. .
MATERIALS & DESIGN, 2015, 66 :93-102
[2]  
Al-Khudairi O., 2014, ADV COMPOSITE MAT AU, P293
[3]  
[Anonymous], 2001, 61400232001 IEC TS
[4]  
[Anonymous], THESIS
[5]  
[Anonymous], 2006, 6140012005A12010 BS
[6]   On the structural topology of wind turbine blades [J].
Buckney, Neil ;
Green, Steven ;
Pirrera, Alberto ;
Weaver, Paul M. .
WIND ENERGY, 2013, 16 (04) :545-560
[7]   Experimental Studies of Stiffness Degradation and Dissipated Energy in Glass Fibre Reinforced Polymer Composite Under Fatigue Loading [J].
Cadavid, M. Ospina ;
Al-Khudairi, O. ;
Hadavinia, H. ;
Goodwin, D. ;
Liaghati, G. H. .
POLYMERS & POLYMER COMPOSITES, 2017, 25 (06) :435-446
[8]   Effects of composite fiber orientation on wind turbine blade buckling resistance [J].
Cox, Kevin ;
Echtermeyer, Andreas .
WIND ENERGY, 2014, 17 (12) :1925-1943
[9]   Improving the fracture toughness and the strength of epoxy using nanomaterials - a review of the current status [J].
Domun, N. ;
Hadavinia, H. ;
Zhang, T. ;
Sainsbury, T. ;
Liaghat, G. H. ;
Vahid, S. .
NANOSCALE, 2015, 7 (23) :10294-10329
[10]   Improving the fracture toughness properties of epoxy using graphene nanoplatelets at low filler content [J].
Domun N. ;
Hadavinia H. ;
Zhang T. ;
Liaghat G. ;
Vahid S. ;
Spacie C. ;
Paton K.R. ;
Sainsbury T. .
Nanocomposites, 2017, 3 (03) :85-96