An Adaptive Non-Linearity Detection Algorithm for Process Control Loops

被引:20
作者
Aftab, Muhammad Faisal [1 ]
Hovd, Morten [1 ]
Huang, Norden E. [2 ]
Sivalingam, Selvanathan [3 ]
机构
[1] NTNU, Dept Engn Cybernet, Trondheim, Norway
[2] Natl Cent Univ, Res Ctr Adapt Data Anal, Taoyuan, Taiwan
[3] Seimens AG, Trondheim, Norway
关键词
Control non-linearities; adaptive algorithm; intra-wave frequency modulation; instantaneous frequency; EMPIRICAL MODE DECOMPOSITION;
D O I
10.1016/j.ifacol.2016.07.336
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Non-linearities are considered to be a major source of oscillations and poor performance in industrial control systems, as 20-30 % of loops are reported to be oscillating due to valve non-linearities (Srinivasan et al. (2005)). This fact has led to a significant effort aimed at the detection and diagnosis of non-linearities: in particular for valve non-linearities in the control loops. The current paper presents an adaptive algorithm, based On HHT (Hilbert Huang Transform), for non-linearity detection and isolation in process systems. The HHT is an adaptive data analysis technique that is applicable to non-linear and non stationary time series. An index termed the Degree of Non-Linearity (DNL), based on intra-wave frequency modulation, is used to identify the presence of non-linearity in the signal generating system. The proposed method is shown to be more robust, in differentiating between linear and nonlinear causes of oscillations when compared to existing methods, and can handle non-stationary effects. (C) 2016, IFAC (International Federation of Automatic Control) Hosting by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1020 / 1025
页数:6
相关论文
共 23 条
[1]  
[Anonymous], 2003, IEEE EURASIP WORKSH
[2]   DETECTION AND QUANTIFICATION OF CONTROL VALVE NONLINEARITIES USING HILBERT-HUANG TRANSFORM [J].
Babji, S. ;
Gorai, P. ;
Tangirala, A. K. .
ADVANCES IN DATA SCIENCE AND ADAPTIVE ANALYSIS, 2009, 1 (03) :425-446
[3]  
Capaci R.D., 2015, PROCESSES 2015, V3, P422
[4]  
Chaudhry M., 2008, DIAGNOSIS PROCESS NO
[5]   Diagnosis of poor control-loop performance using higher-order statistics [J].
Choudhury, MAAS ;
Shah, SL ;
Thornhill, NF .
AUTOMATICA, 2004, 40 (10) :1719-1728
[6]  
Hagglund T., 2011, CONTROL ENG PRACT, V40, P782
[7]   A shape-analysis approach for diagnosis of stiction in control valves [J].
Hagglund, Tore .
CONTROL ENGINEERING PRACTICE, 2011, 19 (08) :782-789
[8]   The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysis [J].
Huang, NE ;
Shen, Z ;
Long, SR ;
Wu, MLC ;
Shih, HH ;
Zheng, QN ;
Yen, NC ;
Tung, CC ;
Liu, HH .
PROCEEDINGS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 1998, 454 (1971) :903-995
[9]  
Huang NE, 2014, US patent, Patent No. [US8732113B2, 8732113]
[10]  
Olsson H., 1996, THESIS