Contact Force-Sensing versus Standard Catheters in Non-Fluoroscopic Radiofrequency Catheter Ablation of Idiopathic Outflow Tract Ventricular Arrhythmias

被引:2
作者
Karkowski, Grzegorz [1 ]
Kuniewicz, Marcin [1 ,2 ]
Zabek, Andrzej [1 ]
Kozluk, Edward [3 ]
Debski, Maciej [4 ]
Matusik, Pawel T. [1 ,5 ]
Lelakowski, Jacek [1 ,5 ]
机构
[1] John Paul 2 Hosp, Dept Electrocardiol, PL-31202 Krakow, Poland
[2] Jagiellonian Univ Med Coll, Dept Anat, PL-31008 Krakow, Poland
[3] Med Univ Warsaw, Dept Cardiol, PL-02097 Warsaw, Poland
[4] Univ East Anglia, Norfolk & Norwich Univ Hosp, Dept Cardiol, Norwich NR4 7TJ, Norfolk, England
[5] Jagiellonian Univ Med Coll, Inst Cardiol, Dept Electrocardiol, PL-31008 Krakow, Poland
关键词
contact force; non-fluoroscopic ablation; outflow tracts; premature ventricular contractions; ventricular arrhythmias; ELECTRODE-TISSUE CONTACT; ATRIAL-FIBRILLATION; STEAM POP; LESION SIZE; SAFETY; IMPEDANCE; EFFICACY;
D O I
10.3390/jcm11030593
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Adequate contact between the catheter tip and tissue is important for optimal lesion formation and, in some procedures, it has been associated with improved effectiveness and safety. We evaluated the potential benefits of contact force-sensing (CFS) catheters during non-fluoroscopic radiofrequency catheter ablation (NF-RFCA) of idiopathic ventricular arrhythmias (VAs) originating from outflow tracts (OTs). Methods: A group of 102 patients who underwent NF-RFCA (CARTO, Biosense Webster Inc., Irvine, CA, USA) of VAs from OTs between 2014 to 2018 was retrospectively analyzed. Results: We included 52 (50.9%) patients in whom NF-RFCA was performed using CFS catheters and 50 (49.1%) who were ablated using standard catheters. Arrhythmias were localized in the right and left OT in 70 (68.6%) and 32 (31.4%) patients, respectively. The RFCA acute success rate was 96.1% (n = 98) and long-term success during a minimum 12-month follow-up (mean 51.3 +/- 21.6 months) was 85.3% (n = 87), with no difference between CFS and standard catheters. There was no difference in complications rate between CFS (n = 1) and standard catheter (n = 2) ablations. Conclusions: There is no additional advantage of CFS catheters use over standard catheters during NF-RFCA of OT-VAs in terms of procedural effectiveness and safety.
引用
收藏
页数:11
相关论文
共 29 条
[1]   Similar outcomes with manual contact force ablation catheters and traditional catheters in the treatment of outflow tract premature ventricular complexes [J].
Abraham, Pal ;
Ambrus, Mercedesz ;
Herczeg, Szilvia ;
Szegedi, Nandor ;
Nagy, Klaudia Vivien ;
Sallo, Zoltan ;
Osztheimer, Istvan ;
Szeplaki, Gabor ;
Tahin, Tamas ;
Merkely, Bela ;
Geller, Laszlo .
EUROPACE, 2021, 23 (04) :596-602
[2]   A prospective study on safety of catheter ablation procedures: Contact force guided ablation could reduce the risk of cardiac perforation [J].
Akca, Ferdi ;
Janse, Petter ;
Theuns, Dominic A. M. J. ;
Szili-Torok, Tamas .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 179 :441-448
[3]  
Baranowski R, 2013, KARDIOL POL, V71, P225
[4]   Acute and one year outcome of premature ventricular contraction ablation guided by contact force and automated pacemapping software [J].
Capulzini, Lucio ;
Vergara, Pasquale ;
Mugnai, Giacomo ;
Salghetti, Francesca ;
Pablo Abugattas, Juan ;
El Bouchaibi, Said ;
Iacopino, Saverio ;
Sieira, Juan ;
Enriquez Coutino, Hugo ;
Stroeker, Erwin ;
Brugada, Pedro ;
Chierchia, Gianbattista ;
de Asmundis, Carlo .
JOURNAL OF ARRHYTHMIA, 2019, 35 (03) :542-549
[5]   Association between the geographic region and the risk of familial atrioventricular nodal reentrant tachycardia in the Polish population [J].
Deutsch, Karol ;
Ciurzynski, Michal ;
Sledz, Janusz ;
Zienciuk-Krajka, Agnieszka ;
Mazij, Mariusz ;
Ludwik, Bartosz ;
Stec, Piotr ;
Wileczek, Antoni ;
Pruszczyk, Piotr ;
Stec, Sebastian .
POLISH ARCHIVES OF INTERNAL MEDICINE-POLSKIE ARCHIWUM MEDYCYNY WEWNETRZNEJ, 2021, 131 (11)
[6]   The safety and efficacy of zero-fluoroscopy ablation versus conventional ablation in patients with supraventricular tachycardia [J].
Fadhle, Alselmi ;
Hu, Mei ;
Wang, Yan .
KARDIOLOGIA POLSKA, 2020, 78 (06) :552-558
[7]   Long-Term Efficacy and Impact on Mortality of Remote Magnetic Navigation Guided Catheter Ablation of Ventricular Arrhythmias [J].
Guckel, Denise ;
Niemann, Sarah ;
Ditzhaus, Marc ;
Molatta, Stephan ;
Bergau, Leonard ;
Fink, Thomas ;
Sciacca, Vanessa ;
El Hamriti, Mustapha ;
Imnadze, Guram ;
Steinhauer, Philipp ;
Braun, Martin ;
Khalaph, Moneeb ;
Noelker, Georg ;
Sommer, Philipp ;
Sohns, Christian .
JOURNAL OF CLINICAL MEDICINE, 2021, 10 (20)
[8]   Safety and Clinical Outcome of Catheter Ablation of Ventricular Arrhythmias Using Contact Force Sensing: Consecutive Case Series [J].
Hendriks, Astrid Armanda ;
Akca, Ferdi ;
Abkenari, Lara Dabiri ;
Khan, Muchtiar ;
Bhagwandien, Rohit ;
Yap, Sing-Chien ;
Wijchers, Sip ;
Szili-Torok, Tamas .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2015, 26 (11) :1224-1229
[9]   Relationship Between Catheter Contact Force and Radiofrequency Lesion Size and Incidence of Steam Pop in the Beating Canine Heart Electrogram Amplitude, Impedance, and Electrode Temperature Are Poor Predictors of Electrode-Tissue Contact Force and Lesion Size [J].
Ikeda, Atsushi ;
Nakagawa, Hiroshi ;
Lambert, Hendrik ;
Shah, Dipen C. ;
Fonck, Edouard ;
Yulzari, Aude ;
Sharma, Tushar ;
Pitha, Jan V. ;
Lazzara, Ralph ;
Jackman, Warren M. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2014, 7 (06) :1174-1180
[10]   Non-fluoroscopic radiofrequency catheter ablation of right- and left-sided ventricular arrhythmias [J].
Karkowski, Grzegorz ;
Kuniewicz, Marcin ;
Kozluk, Edward ;
Chyzy, Tomasz ;
Zabek, Andrzej ;
Dusza, Michal ;
Lelakowski, Jacek .
POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2020, 16 (03) :321-329