Can visual assessment of flow waveform morphology detect anastomotic error in off-pump coronary artery bypass grafting?

被引:23
作者
Jaber, SF [1 ]
Koenig, SC [1 ]
BhaskerRao, B [1 ]
VanHimbergen, DJ [1 ]
Spence, PA [1 ]
机构
[1] Univ Louisville, Dept Surg, Jewish Hosp, Cardiothorac Surg Res Inst, Louisville, KY 40202 USA
关键词
anastomotic quality; off-pump coronary artery bypass grafting; flow probes;
D O I
10.1016/S1010-7940(98)00232-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Flow probes are being used for intraoperative assessment of anastomotic quality during off-pump coronary artery bypass grafting (CABG), We conducted a survey with the cooperation of 19 international surgeons to assess the ability of surgeons to detect anastomotic errors by evaluating mean flow and flow waveform morphology. Material and methods: Mongrel dogs underwent mammary to left anterior descending (LAD) grafting, Mean graft flow and flow wave morphology for varying degrees of anastomotic stenoses were recorded using transit-time flow probes. A questionnaire consisting of ten different recorded how tracings and the corresponding mean flows were given to 20 surgeons from around the world. The surgeons were asked to determine the degree of stenosis and whether they would re-do the anastomosis based upon the mean flow and the flow tracings. Results: All of the 19 surgeons that responded were able to clearly identify a highly stenotic graft (>90% stenosis). However, 24% would re-do a fully patent anastomosis, 58% accepted an anastomosis with moderate stenosis, and 72% accepted anastomoses with severe stenosis. Conclusions: Evaluation of flow tracing morphology and/or mean flows can be used to reliably detect nearly occluded anastomoses (>90% stenosis). However, surgeons should be cautious in assessing anastomoses with lesser degrees of stenosis, as they may be more difficult to reliably interpret. (C) 1998 Elsevier Science B.V, All rights reserved.
引用
收藏
页码:476 / 479
页数:4
相关论文
共 6 条
[1]  
Calafiore A M, 1997, Semin Thorac Cardiovasc Surg, V9, P305
[2]   Midterm results after minimally invasive coronary surgery (last operation) [J].
Calafiore, AM ;
Di Giammarco, G ;
Teodori, G ;
Gallina, S ;
Maddestra, N ;
Paloscia, L ;
Scipioni, G ;
Iovino, T ;
Contini, M ;
Vitolla, G .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 115 (04) :763-770
[3]   ULTRASONIC ASSESSMENT OF INTERNAL THORACIC ARTERY GRAFT FLOW IN THE REVASCULARIZED HEART [J].
CANVER, CC ;
DAME, NA .
ANNALS OF THORACIC SURGERY, 1994, 58 (01) :135-138
[4]   INTRAOPERATIVE ELECTROMAGNETIC FLOWMETER MEASUREMENTS IN CORONARY-ARTERY BYPASS GRAFTS [J].
LOUAGIE, YAG ;
HAXHE, JP ;
BUCHE, M ;
SCHOEVAERDTS, JC .
ANNALS OF THORACIC SURGERY, 1994, 57 (02) :357-364
[5]   VOLUME BLOOD-FLOW MEASUREMENTS WITH A TRANSIT-TIME FLOWMETER - AN IN-VIVO AND IN-VITRO VARIABILITY AND VALIDATION-STUDY [J].
LUNDELL, A ;
BERGQVIST, D ;
MATTSSON, E ;
NILSSON, B .
CLINICAL PHYSIOLOGY, 1993, 13 (05) :547-557
[6]  
SUPRAMANIAN VA, 1997, ANN THORAC SURG, V63, pS68