Comparison of Retinal Nerve Fiber Layer and Central Macular Thickness Measurements Among Five Different Optical Coherence Tomography Instruments in Patients With Multiple Sclerosis and Optic Neuritis

被引:35
|
作者
Watson, George M. [1 ]
Keltner, John L. [1 ,2 ]
Chin, Eric K. [1 ]
Harvey, Danielle [3 ,4 ]
Audrey Nguyen [1 ]
Park, Susanna S. [1 ]
机构
[1] Univ Calif Davis, Dept Ophthalmol & Vis Sci, Ctr Eye, Sacramento, CA 95817 USA
[2] Univ Calif Davis, Med Ctr, Dept Neurol & Neurol Surg, Sacramento, CA 95817 USA
[3] Univ Calif Davis, Div Biostat, Sacramento, CA 95817 USA
[4] Univ Calif Davis, Dept Publ Hlth Sci, Sacramento, CA 95817 USA
关键词
SPECTRAL-DOMAIN; TIME-DOMAIN; STRATUS OCT; AXONAL LOSS; GLAUCOMATOUS EYES; REPRODUCIBILITY; EDEMA; ABNORMALITIES; VARIABILITY; PERFORMANCE;
D O I
10.1097/WNO.0b013e3181facbbd
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: To compare the mean central macular thickness (CMT) and the mean average optic nerve retinal nerve fiber layer (RNFL) thickness in the eyes of patients with a history of optic neuritis and/or multiple sclerosis (MS) using 5 commercially available optical coherence tomography (OCT) instruments. Methods: Cross-sectional study including 46 patients (92 eyes) with a history of optic neuritis and/or MS. Both eyes were imaged on the same day with 5 OCT instruments: 1 time-domain OCT (Stratus) and 4 different Fourier-domain (spectral-domain) OCT (3D OCT-1000, Cirrus, RTVue-100, and Spectralis). Results: Twenty-five patients (50 eyes) were included in the final analysis after excluding patients with diabetes, glaucoma, ocular hypertension, or retinal pathology and inadequate scan quality. Randomized block analysis of variance revealed statistically significant differences across instruments (P < 0.001) for both eyes for mean CMT and mean average optic nerve RNFL. When testing for significant differences in measurements from instrument to instrument, some difference was noted between the right and left eyes. Conclusions: Statistically significant differences exist among commercially available OCT instruments in measuring mean CMT and mean average RNFL thickness in patients with optic neuritis and/or MS. These findings likely result from the differences in data acquisition and segmentation algorithm software among OCT instruments. Awareness of these variations among OCT instruments will be important in using these instruments for clinical trials and management of patients with optic neuritis and/or MS.
引用
收藏
页码:110 / 116
页数:7
相关论文
共 50 条
  • [31] MACULAR THICKNESS MEASUREMENTS IN CENTRAL RETINAL ARTERY OCCLUSION BY OPTICAL COHERENCE TOMOGRAPHY
    Chen, San-Ni
    Hwang, Jiunn-Feng
    Chen, Yan-Ting
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2011, 31 (04): : 730 - 737
  • [32] Comparison of retinal thickness measurements among four different optical coherence tomography devices
    Nam, Ki Tae
    Yun, Cheolmin
    Seo, Myungho
    Ahn, Somin
    Oh, Jaeryung
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [33] RETINAL THICKNESS AND VOLUME MEASUREMENTS IN DIABETIC MACULAR EDEMA A Comparison of Four Optical Coherence Tomography Systems
    Lammer, Jan
    Scholda, Christoph
    Pruente, Christian
    Benesch, Thomas
    Schmidt-Erfurth, Ursula
    Bolz, Matthias
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2011, 31 (01): : 48 - 55
  • [34] Agreement Between Standard Optical Coherence Tomography and Optical Coherence Tomography-Based Angiography in Estimating Retinal Nerve Fiber Layer Thickness
    Yilmaz, Hayati
    Koylu, Mehmet Talay
    Yilmaz, Alper Can
    Durukan, Ali Hakan
    Uysal, Yusuf
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2020, 50 (05): : 264 - 270
  • [35] Peripapillary retinal nerve fiber layer thickness in normal Japanese eyes measured with optical coherence tomography
    Kanno, Makoto
    Nagasawa, Michi
    Suzuki, Michiro
    Yamashita, Hidetoshi
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2010, 54 (01) : 36 - 42
  • [36] Patterns of retinal nerve fiber layer loss in multiple sclerosis patients with or without optic neuritis and glaucoma patients
    Bock, Markus
    Brandt, Alexander U.
    Doerr, Jan
    Kraft, Helga
    Weinges-Evers, Nicholetta
    Gaede, Gunnar
    Pfueller, Caspar F.
    Herges, Katja
    Radbruch, Helena
    Ohlraun, Stephanie
    Bellmann-Strobl, Judith
    Kuchenbecker, Joern
    Zipp, Frauke
    Paul, Friedemann
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2010, 112 (08) : 647 - 652
  • [37] Retinal nerve fiber layer thickness in normal Indian pediatric population measured with optical coherence tomography
    Pawar, Neelam
    Maheshwari, Devendra
    Ravindran, Meenakshi
    Ramakrishnan, Renagappa
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2014, 62 (04) : 412 - 418
  • [38] Comparison of Peripapillary Retinal Nerve Fiber Layer Thickness Measured by Spectral vs. Time Domain Optical Coherence Tomography
    Hong, Samin
    Seong, Gong Je
    Kim, Sung Soo
    Kang, Sung Yong
    Kim, Chan Yun
    CURRENT EYE RESEARCH, 2011, 36 (02) : 125 - 134
  • [39] Evaluation of retinal nerve fiber layer thickness measurements using optical coherence tomography in patients with tobacco-alcohol-induced toxic optic neuropathy
    Moura, Frederico C.
    Monteiro, Mario L.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2010, 58 (02) : 143 - 146
  • [40] Peripapillary retinal nerve fiber layer thickness in different glaucoma stages measured by optical coherence tomography
    Zivkovic, Maja
    Jaksic, Vesna
    Jovanovic, Predrag
    Zlatanovic, Marko
    Zlatanovic, Gordana
    Djordjevic-Jocic, Jasmina
    VOJNOSANITETSKI PREGLED, 2017, 74 (02) : 121 - 126