Comparison of Retinal Nerve Fiber Layer and Central Macular Thickness Measurements Among Five Different Optical Coherence Tomography Instruments in Patients With Multiple Sclerosis and Optic Neuritis

被引:35
作者
Watson, George M. [1 ]
Keltner, John L. [1 ,2 ]
Chin, Eric K. [1 ]
Harvey, Danielle [3 ,4 ]
Audrey Nguyen [1 ]
Park, Susanna S. [1 ]
机构
[1] Univ Calif Davis, Dept Ophthalmol & Vis Sci, Ctr Eye, Sacramento, CA 95817 USA
[2] Univ Calif Davis, Med Ctr, Dept Neurol & Neurol Surg, Sacramento, CA 95817 USA
[3] Univ Calif Davis, Div Biostat, Sacramento, CA 95817 USA
[4] Univ Calif Davis, Dept Publ Hlth Sci, Sacramento, CA 95817 USA
关键词
SPECTRAL-DOMAIN; TIME-DOMAIN; STRATUS OCT; AXONAL LOSS; GLAUCOMATOUS EYES; REPRODUCIBILITY; EDEMA; ABNORMALITIES; VARIABILITY; PERFORMANCE;
D O I
10.1097/WNO.0b013e3181facbbd
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: To compare the mean central macular thickness (CMT) and the mean average optic nerve retinal nerve fiber layer (RNFL) thickness in the eyes of patients with a history of optic neuritis and/or multiple sclerosis (MS) using 5 commercially available optical coherence tomography (OCT) instruments. Methods: Cross-sectional study including 46 patients (92 eyes) with a history of optic neuritis and/or MS. Both eyes were imaged on the same day with 5 OCT instruments: 1 time-domain OCT (Stratus) and 4 different Fourier-domain (spectral-domain) OCT (3D OCT-1000, Cirrus, RTVue-100, and Spectralis). Results: Twenty-five patients (50 eyes) were included in the final analysis after excluding patients with diabetes, glaucoma, ocular hypertension, or retinal pathology and inadequate scan quality. Randomized block analysis of variance revealed statistically significant differences across instruments (P < 0.001) for both eyes for mean CMT and mean average optic nerve RNFL. When testing for significant differences in measurements from instrument to instrument, some difference was noted between the right and left eyes. Conclusions: Statistically significant differences exist among commercially available OCT instruments in measuring mean CMT and mean average RNFL thickness in patients with optic neuritis and/or MS. These findings likely result from the differences in data acquisition and segmentation algorithm software among OCT instruments. Awareness of these variations among OCT instruments will be important in using these instruments for clinical trials and management of patients with optic neuritis and/or MS.
引用
收藏
页码:110 / 116
页数:7
相关论文
共 51 条
[1]   Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes [J].
Budenz, DL ;
Chang, RT ;
Huang, XR ;
Knighton, RW ;
Tielsch, JM .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (07) :2440-2443
[2]   Reproducibility of peripapillary retinal nerve fiber thickness measurements with stratus OCT in glaucomatous eyes [J].
Budenz, Donald L. ;
Fredette, Marie-Josee ;
Feuer, William J. ;
Anderson, Douglas R. .
OPHTHALMOLOGY, 2008, 115 (04) :661-666
[3]   RECOMMENDED STANDARDS FOR ELECTRORETINOGRAMS AND VISUAL-EVOKED POTENTIALS - REPORT OF AN IFCN COMMITTEE [J].
CELESIA, GG ;
BODISWOLLNER, I ;
CHATRIAN, GE ;
HARDING, GFA ;
SOKOL, S ;
SPEKREIJSE, H .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1993, 87 (06) :421-436
[4]   Reproducibility of optical coherence tomography in multiple sclerosis [J].
Cettomai, Deanna ;
Pulicken, Mathew ;
Gordon-Lipkin, Eliza ;
Salter, Amber ;
Frohman, Teresa C. ;
Conger, Amy ;
Zhang, Xiao ;
Cutter, Gary ;
Balcer, Laura J. ;
Frohman, Elliot M. ;
Calabresi, Peter A. .
ARCHIVES OF NEUROLOGY, 2008, 65 (09) :1218-1222
[5]   Spectral domain optical coherence tomography - Ultra-high speed, ultra-high resolution ophthalmic imaging [J].
Chen, TC ;
Cense, B ;
Pierce, MC ;
Nassif, N ;
Park, BH ;
Yun, SH ;
White, BR ;
Bouma, BE ;
Tearney, GJ ;
de Boer, JF .
ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (12) :1715-1720
[6]   Relationship between retinal nerve fiber layer measurement and signal strength in optical coherence tomography [J].
Cheung, Carol Yim Lui ;
Leung, Christopher Kai Shun ;
Lin, Dusheung ;
Pang, Chi-Pui ;
Lam, Dennis Shun Chiu .
OPHTHALMOLOGY, 2008, 115 (08) :1347-1351
[7]   Optical coherence tomography 3: Delineation of the outer neural retinal boundary and its influence on retinal thickness measurements [J].
Costa, RA ;
Calucci, D ;
Skaf, M ;
Cardillo, JA ;
Castro, JC ;
Melo, LA ;
Martins, MC ;
Kaiser, PK .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (07) :2399-2406
[8]   Quantifying tonal loss after optic neuritis with optical coherence tomography [J].
Costello, F ;
Coupland, S ;
Hodge, W ;
Lorello, GR ;
Koroluk, J ;
Pan, YI ;
Freedman, MS ;
Zackon, DH ;
Kardon, RH .
ANNALS OF NEUROLOGY, 2006, 59 (06) :963-969
[9]   Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069
[10]  
*DRCR NET, 2009, DRCR NET IM ACQ PROT, V12