A novel reliable indicator of stator windings fault in induction motor extracted from the symmetrical components

被引:0
作者
Bouzid, M. [1 ,2 ]
Champenois, G. [3 ]
机构
[1] Univ El Manar, LSE ENIT, BP 37 Belvedere, Tunis 1002, Tunisia
[2] Univ 7 November Carthage, ESTI, Tunis, Tunisia
[3] Univ Poitiers, LAII ENSIP, F-86022 Poitiers, France
来源
2011 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE) | 2011年
关键词
Diagnosis; Induction Machine; Inter Turns Short Circuit Fault; Negative Sequence; Stator current; DIAGNOSIS;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The adopted diagnostic procedures in industrial process are based on the monitoring of one or more significant indicators of the considered fault. Therefore, the diagnostic performances depend on the reliability of these fault indicators which should significantly represent the fault. For this purpose the investigation of an effective indicator remains usually the main aim to achieve a correct diagnostic procedure. However, this paper presents a novel and efficient indicator of an inter turns short circuit fault in two stator windings of the induction machine. This fault indicator is the behavior of the angle and the amplitude of the negative sequence component of the stator current. Simulation of different examples of stator faults are carried out to study the behavior of this indicator. Accordingly, this paper points out the existence of a powerful link between the angle of the negative sequence of the current and the faulty phases. This link offers an attractive approach to identify the two faulty phases and to indicate the phase the more affected by the fault. It is also demonstrate that the amplitude of the negative sequence of the stator current yield to determinate the severity of the fault. Experimental test are also carried out to validate the behavior of this indicator of fault. These potential advantages prove the effectiveness and the reliability of the proposed indicator of the fault, useful to accomplish a correct diagnostic procedure.
引用
收藏
页数:7
相关论文
共 11 条
[1]   Diagnosis by parameter estimation of stator and rotor faults occurring in induction machines [J].
Bachir, Smail ;
Tnani, Slim ;
Trigeassou, Jean-Claude ;
Champenois, Gerard .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (03) :963-973
[2]  
Bonnett AH, 2008, IEEE IND APPL MAG, V14, P29, DOI 10.1109/MIA.2007.909802
[3]  
Bouzid M., 2007, IEE IET I ENG TECHN
[4]   An Effective Neural Approach for the Automatic Location of Stator Interturn Faults in Induction Motor [J].
Bouzid, Monia Ben Khader ;
Champenois, Gerard ;
Bellaaj, Najiba Mrabet ;
Signac, Laurent ;
Jelassi, Khaled .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (12) :4277-4289
[5]  
Filippetti F., 1996, P ICEM
[6]   Online diagnosis of induction motors using MCSA [J].
Jung, Jee-Hoon ;
Lee, Jong-Jae ;
Kwon, Bong-Hwan .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (06) :1842-1852
[7]   Condition monitoring of stator windings in induction motors: Part I - Experimental investigation of the effective negative-sequence impedance detector [J].
Kohler, JL ;
Sottile, J ;
Trutt, FC .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2002, 38 (05) :1447-1453
[8]   A robust, on-line turn-fault detection technique for induction machines based on monitoring the sequence component impedance matrix [J].
Lee, SB ;
Tallam, RM ;
Habetler, TG .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2003, 18 (03) :865-872
[9]   A review of stator fault, monitoring techniques of induction motors [J].
Siddique, A ;
Yadava, GS ;
Singh, B .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2005, 20 (01) :106-114
[10]   A survey of methods for detection of stator-related faults in induction machines [J].
Tallam, Rangarajan M. ;
Lee, Sang Bin ;
Stone, Greg C. ;
Kliman, Gerald B. ;
Yoo, Jiyoon ;
Habetler, Thomas G. ;
Harley, Ronald G. .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2007, 43 (04) :920-933