Distributed Passive Actuation Schemes for Seismic Protection of Multibuilding Systems

被引:4
作者
Palacios-Quinonero, Francisco [1 ]
Rubio-Massegu, Josep [1 ]
Rossell, Josep M. [1 ]
Karimi, Hamid Reza [2 ]
机构
[1] Univ Politecn Cataluna, EPSEM, Dept Math, Ave Bases Manresa 61-73, Manresa 08242, Spain
[2] Politecn Milan, Dept Mech Engn, Via La Masa 1, I-20156 Milan, Italy
来源
APPLIED SCIENCES-BASEL | 2020年 / 10卷 / 07期
关键词
energy-dissipation systems; distributed damping systems; optimal placement; multibuilding systems; seismic protection; hybrid genetic algorithm; parallel computing; pounding protection; VISCOUS DAMPERS; ENERGY-DISSIPATION; BUILDING STRUCTURES; H-INFINITY; DESIGN; CONFIGURATION; OPTIMIZATION; EFFICIENCY; PLACEMENT;
D O I
10.3390/app10072383
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this paper, we investigate the design of distributed damping systems (DDSs) for the overall seismic protection of multiple adjacent buildings. The considered DDSs contain interstory dampers implemented inside the buildings and also interbuilding damping links. The design objectives include mitigating the buildings seismic response by reducing the interstory-drift and story-acceleration peak-values and producing small interbuilding approachings to decrease the risk of interbuilding collisions. Designing high-performance DDS configurations requires determining convenient damper positions and computing proper values for the damper parameters. That allocation-tuning optimization problem can pose serious computational difficulties for large-scale multibuilding systems. The design methodology proposed in this work-(i) is based on an effective matrix formulation of the damped multibuilding system; (ii) follows an H infinity approach to define an objective function with fast-evaluation characteristics; (iii) exploits the computational advantages of the current state-of-the-art genetic algorithm solvers, including the usage of hybrid discrete-continuous optimization and parallel computing; and (iv) allows setting actuation schemes of particular interest such as full-linked configurations or nonactuated buildings. To illustrate the main features of the presented methodology, we consider a system of five adjacent multistory buildings and design three full-linked DDS configurations with a different number of actuated buildings. The obtained results confirm the flexibility and effectiveness of the proposed design approach and demonstrate the high-performance characteristics of the devised DDS configurations.
引用
收藏
页数:30
相关论文
共 44 条
[1]   Pounding hazard mitigation between adjacent planar buildings using coupling strategy [J].
Abdeddaim M. ;
Ounis A. ;
Djedoui N. ;
Shrimali M.K. .
Journal of Civil Structural Health Monitoring, 2016, 6 (03) :603-617
[2]   Importance of interstory velocity on optimal along-height allocation of viscous oil dampers in super high-rise buildings [J].
Adachi, Fuyuki ;
Fujita, Kohei ;
Tsuji, Masaaki ;
Takewaki, Izuru .
ENGINEERING STRUCTURES, 2013, 56 :489-500
[3]   Optimal Viscous Damper Placement for Elastic-Plastic MDOF Structures Under Critical Double Impulse [J].
Akehashi, Hiroki ;
Takewaki, Izuru .
FRONTIERS IN BUILT ENVIRONMENT, 2019, 5
[4]  
Ali M.M., 2007, Archit Sci Rev, V50, P205, DOI [10.3763/asre.2007.5027, DOI 10.3763/ASRE.2007.5027]
[5]   Analysis of efficiency of passive dampers in multistorey buildings [J].
Aydin, Ersin ;
Ozturk, Baki ;
Dutkiewicz, Maciej .
JOURNAL OF SOUND AND VIBRATION, 2019, 439 :17-28
[6]  
Balas G.J., 2019, MATLAB ROBUST CONTRO
[7]   Optimal Design and Distribution of Viscous Dampers for Shear Building Structures Under Seismic Excitations [J].
Cetin, Huseyin ;
Aydin, Ersin ;
Ozturk, Baki .
FRONTIERS IN BUILT ENVIRONMENT, 2019, 5
[8]  
Chopra A.K, 2007, Dynamics of structures: theory and applications to earthquake engineering
[9]   Design strategies of viscous dampers for seismic protection of building structures: A review [J].
De Domenico, D. ;
Ricciardi, G. ;
Takewaki, I. .
SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2019, 118 :144-165
[10]   Earthquake protection of structures with nonlinear viscous dampers optimized through an energy-based stochastic approach [J].
De Domenico, D. ;
Ricciardi, G. .
ENGINEERING STRUCTURES, 2019, 179 :523-539