Image-enhanced surgical navigation for endoscopic sinus surgery: evaluating calibration, registration and tracking

被引:32
作者
Lapeer, R. [1 ]
Chen, M. S. [1 ]
Gonzalez, G. [1 ]
Linney, A. [2 ]
Alusi, G. [3 ]
机构
[1] Univ E Anglia, Sch Comp Sci, Norwich NR4 7TJ, Norfolk, England
[2] UCL, Ear Inst, London, England
[3] St Bartholomews Hosp, London, England
关键词
endoscopic sinus surgery; image-guided surgery; surgical navigation; augmented reality; image enhancement;
D O I
10.1002/rcs.175
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Endoscopic sinus surgery (ESS) is generally applied to treat sinusitis when medication is not effective in eliminating the symptoms. Images captured by the endoscope are viewed on a monitor placed near the surgeon. Due to the separation of the handling of the endoscope from the viewing of the image, ESS requires surgeons to have well-trained hand-eye coordination. Unlike the use of the stereo surgical microscope in ENT, the endoscope does not provide the stereo cue for depth perception, hence a surgeon can only perceive depth through motion and shading, which may affect the accuracy of tool placement. Whilst the skill and experience of the surgeon are important factors to the success of ESS, the assistance of image-enhanced surgical navigation (IESN) can further reassure the surgeon's judgement and enhance surgical performance. Methods We developed and validated an IESN system (ARView) for a rigid zero-degree endoscope, typically used for ESS. We present the interface, and calibration and registration (pre-operative and intra-operative) methods of the system. We then quantitatively assess the performance of each of the steps needed to generate the overlay of a real endoscope image with its 'virtual' counterpart, obtained from computed tomography (CT) image data of a real skull. These steps include calibration, registration, motion tracking and final overlay. Results Calibration results using a planar calibration object displayed optimized object space errors of 0.025 +/- 0.013 mm, whilst a non-planar calibration object displayed errors of 0.12 +/- 0.08 mm. Target registration errors (TRES) near the region of interest (ROI), using our pre-operative registration method with the calibration object located near the mouth of the patient (skull), were 2.3 +/- 0.4 mm. The proposed photo-consistency method for intra-operative registration has not yet yielded satisfactory results for ESS-based IESN. (RMS) values for tracking accuracy were found to be around 1.2 mm in a typical workspace of 400 x 400 mm. Object space overlay errors in a small measurement volume of 10 x 10 x 10 mm were found to be around 0.4 +/- 0.02 mm. Conclusions We conclude that, in agreement with individual experiments, the current overall overlay accuracy is of the order of 2-3 mm in the x-y plane, which is in line with current conventional SN systems. The method which is most in need of improvement is registration, hence we wish to investigate the application of the proposed photo-consistency method further. Copyright (C) 2008 John Wiley & Sons, Ltd.
引用
收藏
页码:32 / 45
页数:14
相关论文
共 21 条
[1]   Merging virtual objects with the real world: seeing ultrasound imagery within the patient [J].
Bajura, Michael ;
Fuchs, Henry ;
Ohbuchi, Ryutarou .
Computer Graphics (ACM), 1992, 26 (02) :203-210
[2]   Image-enhanced endoscopy calibration and image registration accuracy testing [J].
Bax, MR ;
Khadem, R ;
Johnson, JA ;
Wilkinson, EP ;
Shahidi, R .
MEDICAL IMAGING 2002: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2002, 4681 :119-126
[3]   A METHOD FOR REGISTRATION OF 3-D SHAPES [J].
BESL, PJ ;
MCKAY, ND .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) :239-256
[4]  
Chen MS, 2005, STUD HEALTH TECHNOL, V111, P87
[5]  
CHEN MS, 2007, THESIS U E ANGLIA UK
[6]   Using photo-consistency to register 2D optical images of the human face to a 3D surface model [J].
Clarkson, MJ ;
Rueckert, D ;
Hill, DLG ;
Hawkes, DJ .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2001, 23 (11) :1266-1280
[7]  
Edwards P J, 1995, J Image Guid Surg, V1, P172, DOI 10.1002/(SICI)1522-712X(1995)1:3<172::AID-IGS7>3.0.CO
[8]  
2-7
[9]   Design and evaluation of a system for microscope-assisted guided interventions (MAGI) [J].
Edwards, PJ ;
King, AP ;
Maurer, CR ;
de Cunha, DA ;
Hawkes, DJ ;
Hill, DLG ;
Gaston, RP ;
Fenlon, MR ;
Jusczyzck, A ;
Strong, AJ ;
Chandler, CL ;
Gleeson, MJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (11) :1082-1093
[10]   Predicting error in rigid-body point-based registration [J].
Fitzpatrick, JM ;
West, JB ;
Maurer, CR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) :694-702