Dual-Mode Electrochemical Assay of Prostate-Specific Antigen Based on Antifouling Peptides Functionalized with Electrochemical Probes and Internal References

被引:83
作者
Ding, Caifeng [1 ,2 ]
Wang, Xinyan [1 ,2 ]
Luo, Xiliang [1 ]
机构
[1] Qingdao Univ Sci & Technol, Key Lab Opt Elect Sensing & Analyt Chem Life Sci, Shandong Key Lab Biochem Anal, Key Lab Analyt Chem Life Sci,Univ Shandong,Minist, Qingdao 266042, Shandong, Peoples R China
[2] Qingdao Univ Sci & Technol, Coll Chem & Mol Engn, Qingdao 266042, Shandong, Peoples R China
基金
中国国家自然科学基金;
关键词
PSA; IMMUNOASSAY; FERROCENE; BIOSENSOR; EFFICIENT; ACID;
D O I
10.1021/acs.analchem.9b04206
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sensitive and selective detection of target analytes in complex biological samples is currently a major challenge. Herein we constructed a dual-mode antifouling electrochemical sensing platform for the detection of prostate-specific antigen (PSA) based on two kinds of antifouling peptides functionalized with a graphene oxide-Fe3O4-thionine (GO-Fe3O4-Thi) probe and internal reference ferrocene (Fc), respectively. The longer peptide (Pep1) modified with the GO-Fe3O4-Thi probe was designed to contain a peptide sequence (HSSKLQK) capable of being recognized and cut by PSA. The GO-Fe3O4-Thi probe functions not only as a peroxidase mimick (GO-Fe3O4) but also works as an electrochemical probe due to the presence of thionine (Thi). The concentration of PSA can be measured through both the increase of differential pulse voltammetry (DPV) signal change of Thi and the decrease of chronoamperometry (CA) signal of the reduction of H2O2 electrocatalyzed by GO-Fe3O4. The shorter peptide (Pep2) was tagged with Fc, whose DPV signal remained constant and was independent of the presence of PSA, and it was used as an internal reference to ensure the reliability and accuracy of the measurement. The dual-mode PSA sensor exhibits a wide linear range from 5 pg/mL to 10 ng/mL, with low detection limits of 0.76 and 0.42 pg/mL through DPV and CA modes, respectively. More importantly, owing to the antifouling capability of the designed peptides, the biosensor performances remained operable even in human serum, indicating feasibility of the electrochemical biosensor for practical PSA quantification in complex samples.
引用
收藏
页码:15846 / 15852
页数:7
相关论文
共 42 条
[1]   Homogenous growth of gold nanocrystals for quantification of PSA protein biomarker [J].
Cao, Cuong ;
Li, Xinxing ;
Lee, Jeewon ;
Sim, Sang Jun .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (05) :1292-1297
[2]   PSA Detection with Femtomolar Sensitivity and a Broad Dynamic Range Using SERS Nanoprobes and an Area-Scanning Method [J].
Chang, Hyejin ;
Kang, Homan ;
Ko, Eunbyeol ;
Jun, Bong-Hyun ;
Lee, Ho-Young ;
Lee, Yoon-Sik ;
Jeang, Dae Hong .
ACS SENSORS, 2016, 1 (06) :645-649
[3]   Ultra-low fouling peptide surfaces derived from natural amino acids [J].
Chen, Shengfu ;
Cao, Zhiqiang ;
Jiang, Shaoyi .
BIOMATERIALS, 2009, 30 (29) :5892-5896
[4]   Electrochemical Immunosensors for Detection of Cancer Protein Biomarkers [J].
Chikkaveeraiah, Bhaskara V. ;
Bhirde, Ashwinkumar A. ;
Morgan, Nicole Y. ;
Eden, Henry S. ;
Chen, Xiaoyuan .
ACS NANO, 2012, 6 (08) :6546-6561
[5]   Mixed Self-Assembled Aptamer and Newly Designed Zwitterionic Peptide as Antifouling Biosensing Interface for Electrochemical Detection of alpha-Fetoprotein [J].
Cui, Min ;
Wang, Yu ;
Jiao, Mingxia ;
Jayachandran, Silambarasan ;
Wu, Yumin ;
Fan, Xiaojian ;
Luo, Xiliang .
ACS SENSORS, 2017, 2 (04) :490-494
[6]  
De Angelis Gabriela, 2007, Rev Urol, V9, P113
[7]  
Denmeade SR, 1997, CANCER RES, V57, P4924
[8]   Ratiometric Electrogenerated Chemiluminescence Cytosensor Based on Conducting Polymer Hydrogel Loaded with Internal Standard Molecules [J].
Ding, Caifeng ;
Li, Yunxia ;
Wang, Lei ;
Luo, Xiliang .
ANALYTICAL CHEMISTRY, 2019, 91 (01) :983-989
[9]   Graphene oxide-Fe3O4 magnetic nanocomposites with peroxidase-like activity for colorimetric detection of glucose [J].
Dong, Ya-lei ;
Zhang, Hui-ge ;
Rahman, Zia Ur ;
Su, Li ;
Chen, Xiao-jiao ;
Hu, Jing ;
Chen, Xing-guo .
NANOSCALE, 2012, 4 (13) :3969-3976
[10]   FERROCENE AS AN INTERNAL STANDARD FOR ELECTROCHEMICAL MEASUREMENTS [J].
GAGNE, RR ;
KOVAL, CA ;
LISENSKY, GC .
INORGANIC CHEMISTRY, 1980, 19 (09) :2854-2855