Monolithic polycapillary x-ray optics engineered to meet a wide range of applications

被引:51
作者
Ding, X [1 ]
Gao, N [1 ]
Havrilla, G [1 ]
机构
[1] Beijing Normal Univ, Inst Low Energy Nucl Phys, Beijing Radiat Ctr, Beijing 100875, Peoples R China
来源
ADVANCES IN LABORATORY-BASED X-RAY SOURCES AND OPTICS | 2000年 / 4144卷
关键词
x-ray optic; x-ray focusing; polycapillary optics; XRF; MXRF; position sensitive x-ray detector;
D O I
10.1117/12.405891
中图分类号
O7 [晶体学];
学科分类号
0702 ; 070205 ; 0703 ; 080501 ;
摘要
Two new applications of monolithic polycapillary x-ray optics were explored. One was to improve the detection sensitivity of microbeam x-ray fluorescence (MXRF) analysis for radioactive samples. One focusing optic was used to focus x-rays onto a small area of the sample, and the second focusing optic was used as a spatial filter to collect xray fluorescence from the area defined by the first optic. The radiation background from the radioisotope in the sample was significantly reduced, and therefore the detection sensitivity for such samples was greatly enhanced. The other application was using a focusing optic to improve performance of position-sensitive-detector (PSD)-based wavelength-dispersive rr-ray fluorescence (WDXRF) analysis. The small, intense excitation beam obtained with a focusing optic greatly increased the count rate of the measurement, thus improving the detection sensitivity of the system. Some new progresses achieved in monolithic polycapillary optics design and manufacturing are also discussed.
引用
收藏
页码:174 / 182
页数:9
相关论文
共 8 条
[1]   IMPROVED CAPILLARY OPTICS APPLIED TO MICROBEAM X-RAY-FLUORESCENCE - RESOLUTION AND SENSITIVITY [J].
ATTAELMANAN, A ;
VOGLIS, P ;
RINDBY, A ;
LARSSON, S ;
ENGSTROM, P .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (01) :24-27
[2]   AN X-RAY SPECTROMETER WITH A POSITION-SENSITIVE WIRE DETECTOR (PSD) [J].
EBEL, H ;
MANTLER, M ;
GURKER, N ;
WERNISCH, J .
X-RAY SPECTROMETRY, 1983, 12 (01) :47-49
[3]   Enhancement of microbeam x-ray fluorescence analysis using monolithic polycapillary focusing optics [J].
Gao, N ;
Ponomarev, IY ;
Xiao, QF ;
Gibson, WM ;
Carpenter, DA .
APPLIED PHYSICS LETTERS, 1997, 71 (23) :3441-3443
[4]  
MATNEY KM, 1997 DENV C
[5]  
ULLRICH J, 1999, 1999 DENV C
[6]   High-resolution, energy-dispersive microcalorimeter spectrometer for X-ray microanalysis [J].
Wollman, DA ;
Irwin, KD ;
Hilton, GC ;
Dulcie, LL ;
Newbury, DE ;
Martinis, JM .
JOURNAL OF MICROSCOPY-OXFORD, 1997, 188 :196-223
[7]  
XIAO QF, 1992, SPIE, V1736, P227
[8]  
YIMING Y, 1993, NUCL INSTRUM METH B, V82, P121