Demonstration of an absolute Rayleigh scattering spectral calibration on the W7-X Thomson scattering system

被引:4
作者
Scott, E. R. [1 ]
Beurskens, M. N. A. [1 ]
Bozhenkov, S. A. [1 ]
Fuchert, A. G. [1 ]
Hirsch, M. [1 ]
Nelde, P. [2 ]
Pasch, E. [1 ]
Wolf, R. C. [1 ,2 ]
机构
[1] Max Planck Inst Plasma Phys, D-17491 Greifswald, Germany
[2] Tech Univ Berlin, D-10623 Berlin, Germany
来源
JOURNAL OF INSTRUMENTATION | 2019年 / 14卷
关键词
Detector alignment and calibration methods (lasers; sources; particle-beams); Plasma diagnostics - interferometry; spectroscopy and imaging; Lasers; DESIGN; LIGHT;
D O I
10.1088/1748-0221/14/10/C10033
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A novel in-situ calibration method for Thomson scattering (TS) diagnostics has been demonstrated on the Wendelstein 7-X stellarator (W7-X). Utilizing a laser-pumped optical parametric oscillator (OPO), Rayleigh scattering measurements were performed in-situ in argon, nitrogen, and air at pressures from 0 to 1024 mbar and wavelengths between 730 and 1070 nm. As the OPO follows the same beam path as the TS lasers, the scattering angle and solid angle of collection can be made identical to the TS geometry; therefore, the calibration covers all optical components within the TS system, including the first vacuum window, and can, in principle, be used to directly calibrate each filter channel for absolute plasma density. Despite high background stray light levels, the Rayleigh scattered signal was successfully isolated from the stray light, and filter curves for multiple polychromators were resolved. The complete calibration system, planned for future W7-X operational campaigns, will aim to further reduce stray light, thereby decreasing the required gas pressure and allowing in-situ calibration measurements on service days. This is planned in part by better matching the OPO beam alignment, size, and divergence to the installed Nd:YAG TS lasers. In addition, the OPO bandwidth will be improved by using an injection seeder to increase filter edge resolution.
引用
收藏
页数:13
相关论文
共 22 条
  • [1] *ASTM INT, 2003, G17303 ASTM INT
  • [2] On using Rayleigh scattering for in situ spectral calibration of Thomson scattering diagnostics
    Bozhenkov, S. A.
    Heym, S. J.
    Beurskens, M. N. A.
    Fuchert, G.
    Pasch, E.
    Scott, E. R.
    Wolf, R. C.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (03)
  • [3] The Thomson scattering diagnostic at Wendelstein 7-X and its performance in the first operation phase
    Bozhenkov, S. A.
    Beurskens, M.
    Dal Molin, A.
    Fuchert, G.
    Pasch, E.
    Stoneking, M. R.
    Hirsch, M.
    Hoefel, U.
    Knauer, J.
    Svensson, J.
    Mora, H. Trimino
    Wolf, R. C.
    [J]. JOURNAL OF INSTRUMENTATION, 2017, 12
  • [4] Real-time dispersion interferometry for density feedback in fusion devices
    Brunner, K. J.
    Akiyama, T.
    Hirsch, M.
    Knauer, J.
    Kornejew, P.
    Kursinski, B.
    Laqua, H.
    Meineke, J.
    Mora, H. Trimino
    Wolf, R. C.
    [J]. JOURNAL OF INSTRUMENTATION, 2018, 13
  • [5] RAYLEIGH-SCATTERING CALCULATIONS FOR THE TERRESTRIAL ATMOSPHERE
    BUCHOLTZ, A
    [J]. APPLIED OPTICS, 1995, 34 (15): : 2765 - 2773
  • [6] DESIGN AND OPERATION OF THE MULTIPULSE THOMSON SCATTERING DIAGNOSTIC ON DIII-D
    CARLSTROM, TN
    CAMPBELL, GL
    DEBOO, JC
    EVANKO, R
    EVANS, J
    GREENFIELD, CM
    HASKOVEC, J
    HSIEH, CL
    MCKEE, E
    SNIDER, RT
    STOCKDALE, R
    TROST, PK
    THOMAS, MP
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (10) : 4901 - 4906
  • [7] DESIGN OF THE DIVERTOR THOMSON SCATTERING SYSTEM ON DIII-D
    CARLSTROM, TN
    FOOTE, JH
    NILSON, DG
    RICE, BW
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (01) : 493 - 495
  • [8] ROTATIONAL RAMAN CALIBRATION OF THOMSON SCATTERING
    HOWARD, J
    JAMES, BW
    SMITH, WIB
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1979, 12 (09) : 1435 - 1440
  • [9] Edge and core Thomson scattering systems and their calibration on the ASDEX Upgrade tokamak
    Kurzan, B.
    Murmann, H. D.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (10)
  • [10] Alignment of the Thomson scattering diagnostic on NSTX
    LeBlanc, B. P.
    Diallo, A.
    [J]. JOURNAL OF INSTRUMENTATION, 2013, 8