Reducing Mis-registration and Shadow Effects on Change Detection in Wetlands

被引:9
|
作者
Zhu, Jinxia [1 ,2 ]
Guo, Qinghua [1 ]
Li, Donghai [1 ]
Harmon, Thomas C. [1 ]
机构
[1] Univ Calif Merced, Sch Engn, Sierra Nevada Res Inst, Merced, CA 95343 USA
[2] Zhejiang Univ, Inst Remote Sensing & Informat Syst Applicat, Hangzhou 310029, Zhejiang, Peoples R China
来源
PHOTOGRAMMETRIC ENGINEERING AND REMOTE SENSING | 2011年 / 77卷 / 04期
基金
美国国家科学基金会;
关键词
OBJECT-BASED CLASSIFICATION; CORRELATION IMAGE-ANALYSIS; DIGITAL CHANGE DETECTION; MISREGISTRATION; ACCURACY; IMPACT; TM;
D O I
10.14358/PERS.77.4.325
中图分类号
P9 [自然地理学];
学科分类号
0705 ; 070501 ;
摘要
With respect to the inevitable mis-registration and shadow effects on change detection analysis, we propose object-based post-classification of the Multivariate Alteration Detection components (OB-MAD). Very high spatial resolution images of drained, managed wetland ponds were used to compare the proposed OB-MAD method with three commonly used classification methods in terms of minimizing the influence of mis-registration and shadow on the change detection analysis: (a) the traditional MAD method with thresholds (Threshold-MAD), (b) a pixel-based post-classification of MAD components with decision tree analysis (PB-MAD), and (c) a traditional object-based post-classification method (OB-traditional). The Ob-MAD method, which utilizes shape and textural information of objects derived from MAD components, produced the highest accuracy with respect to wetland change detection and successfully minimized the influence from the geometric distortion and shadow on the changed area.
引用
收藏
页码:325 / 334
页数:10
相关论文
共 50 条
  • [21] Mis-registration Effect between Quantitative SPECT and CT on Activity Estimation for Targeted Radionuclide Therapy Dosimetry
    Li, Tiantian
    Mok, Greta
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [22] A Two-Stage Multi-Focus Image Fusion Framework Robust to Image Mis-Registration
    Ji, Zhaoyang
    Kang, Xudong
    Zhang, Kunzhong
    Duan, Puhong
    Hao, Qiaobo
    IEEE ACCESS, 2019, 7 : 123231 - 123243
  • [23] Track Mis-Registration Estimator Based on K-Means Algorithm for Bit-Patterned Media Recording
    Jeong, Seongkwon
    Lee, Jaejin
    IEEE TRANSACTIONS ON MAGNETICS, 2023, 59 (03)
  • [24] A robust region-based multiscale image fusion scheme for mis-registration problem of thermal and visible images
    Charoentam, O.
    Patanavijit, V.
    Jitapunkul, S.
    18TH INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION, VOL 3, PROCEEDINGS, 2006, : 669 - +
  • [25] Sociology of mis-registration (being registered to vote elsewhere than in current place of residence) in France and impact on voter turnout
    Braconnier, Celine
    Dormagen, Jean-Yves
    Gabalda, Ghislain
    Niel, Xavier
    REVUE FRANCAISE DE SOCIOLOGIE, 2016, 57 (01): : 17 - 44
  • [26] A multiscale technique for reducing registration noise in change detection on multitemporal VHR images
    Bovolo, Francesca
    Bruzzone, Lorenzo
    Marchesi, Silvia
    2007 INTERNATIONAL WORKSHOP ON THE ANALYSIS OF MULTI-TEMPORAL REMOTE SENSING IMAGES, 2007, : 21 - 26
  • [27] Polarimetric change detection for wetlands
    Schmitt, A.
    Brisco, B.
    Kaya, S.
    Murnaghan, K.
    REMOTE SENSING AND HYDROLOGY, 2012, 352 : 375 - +
  • [28] Robust registration for change detection
    Darkner, Sune
    Hansen, Dan Witzner
    Paulsen, Rasmus R.
    Larsen, Rasmus
    MEDICAL IMAGING 2008: IMAGE PROCESSING, PTS 1-3, 2008, 6914
  • [29] Effects of mis-registration of CT attenuation-corrected on myocardial perfusion images acquired using multi-focus fan beam collimator SPECT/CT and conventional SPECT
    Onishi, H.
    Nakamoto, K.
    Kenda, S.
    Kangai, Y.
    Yada, N.
    Saho, T.
    Sakai, T.
    Hasegawa, D.
    Fukunaga, M.
    Amijima, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S359 - S359
  • [30] Reducing the effects of misregistration on pixel-level change detection
    Stow, DA
    INTERNATIONAL JOURNAL OF REMOTE SENSING, 1999, 20 (12) : 2477 - 2483