Detection of phthalates in water using ultra performance liquid chromatography-electrospray ionization tandem mass spectrometry MRM mode- 'ghost peaks' and measurement methodology

被引:13
作者
Li, Wei [1 ]
Duan, Jinming [1 ]
机构
[1] Xian Univ Architecture & Technol, Key Lab NW Water Resources Environm & Ecol, MOE, Xian 710055, Peoples R China
关键词
TRACE ANALYSIS; METABOLITES; ESTERS; HPLC; CONTAMINATION; DEGRADATION; DERIVATIVES; URINE;
D O I
10.1039/c0ay00507j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the analysis of phthalates, specifically diethyl phthalate (DEP), dibutyl phthalate (DBP), butylbenzyl phthalate (BBP), and diethylhexyl phthalate (DEHP) using ultra performance liquid chromatography-electrospray ionization tandem mass spectrometry (UPLC-ESI-MS/MS), 'ghost peaks' appeared when a gradient liquid chromatography elution mode was employed. A systematic diagnostic analytical protocol was designed to show that the source of the persistent 'ghost peaks', which jeopardized a quantitative analysis of these endocrine disruptors was the mobile phase. A trace amount of DEHP in the mobile phase, either from ultrapure water or organic solvent, was responsible for the observed phenomenon. In contrast to gradient elution, isocratic chromatographic elution mode (ICEM) was found to be free of the problem at the expense of less effective separation of DBP and BBP. Thus, a detection method for analyzing the phthalates is proposed based on ICEM and the multiple reaction monitoring (MRM) mode with multi-channel detection in the UPLC-MS/MS. In the method development, tap water matrix effects were examined and a solution for detection intensity suppression in the analysis of tap water samples was proposed. An addition of methanol into tap water samples could basically relieve the signal detection suppression by the real water matrix. This provides a detection method of these trace environmental pollutants with a linear range between 0.5 to 50 ng mL(-1) and detection limits (LODs) (0.32-0.54 ng mL(-1)) without need of sample pre-concentration. This is a much simpler and faster method than gas chromatography-electron capture detection (GC-ECD) and gas chromatography-mass spectrometry (GC-MS), with comparable detection sensitivity.
引用
收藏
页码:314 / 321
页数:8
相关论文
共 35 条
[21]   Monitoring the sonochemical degradation of phthalate esters in water using solid-phase microextraction [J].
Psillakis, E ;
Mantzavinos, D ;
Kalogerakis, N .
CHEMOSPHERE, 2004, 54 (07) :849-857
[22]  
Reich E., 2006, High performance-thin layer chromatography for the analysis ofmedicinal plants
[23]   An investigation into possible sources of phthalate contamination in the environmental analytical laboratory [J].
Reid, Antoinette M. ;
Brougham, Concepta A. ;
Fogarty, Andrew M. ;
Roche, James J. .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2007, 87 (02) :125-133
[24]   Considerations on ultra-trace analysis of phthalates in drinking water [J].
Serodio, P. ;
Nogueira, J. M. F. .
WATER RESEARCH, 2006, 40 (13) :2572-2582
[25]   Screening, determination and confirmation of chloramphenicol in seafood, meat and honey using ELISA, HPLC-UVD, GC-ECD, GC-MS-EI-SIM and GCMS-NCI-SIM methods [J].
Shen, HY ;
Jiang, HL .
ANALYTICA CHIMICA ACTA, 2005, 535 (1-2) :33-41
[26]   Improved quantitative detection of 11 urinary phthalate metabolites in humans using liquid chromatography-atmospheric pressure chemical ionization tandem mass spectrometry [J].
Silva, MJ ;
Malek, NA ;
Hodge, CC ;
Reidy, JA ;
Kato, K ;
Barr, DB ;
Needham, LL ;
Brock, JW .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 789 (02) :393-404
[27]  
SNYDER LR, 1997, PRACTICAL HPLC METHO, pCH14
[28]  
U.S. Environmental Protection Agency (EPA), 2000, ASS VAL NOND NONQ PE
[29]  
US EPA, 1995, 5252 US EPA
[30]  
*US EPA, 1993, 606 US EPA