On-line duplex molecularly imprinted solid-phase extraction for analysis of low-abundant biomarkers in human serum by liquid chromatography-tandem mass spectrometry

被引:12
|
作者
McKitterick, Nicholas [1 ]
Bicak, Tugrul Cem [2 ]
Switnicka-Plak, A. Magdalena [2 ]
Cormack, A. G. Peter [2 ]
Reubsaet, Leon [1 ]
Halvorsen, Trine Gronhaug [1 ]
机构
[1] Univ Oslo, Sect Pharmaceut Chem, Dept Pharm, POB 1068 Blindern, N-0316 Oslo, Norway
[2] Univ Strathclyde, Dept Pure & Appl Chem, WestCHEM, Thomas Graham Bldg,295 Cathedral St, Glasgow G1 1XL, Lanark, Scotland
基金
欧盟地平线“2020”;
关键词
On-line SPE; Multiplexing; Molecularly imprinted polymers; LC-MS/MS; Low-abundant biomarkers; Targeted bottom-up proteomics; NEURON-SPECIFIC ENOLASE; POLYMERS; LUNG; QUANTIFICATION; SAMPLES; IMMUNOCAPTURE; DIGESTION; ENRICHMENT; ANTIBODIES; PROTEINS;
D O I
10.1016/j.chroma.2021.462490
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the present work, a pair of molecularly imprinted polymers (MIPs) targeting distinct peptide targets were packed into trap columns and combined for automated duplex analysis of two low abundant small cell lung cancer biomarkers (neuron-specific enolase [NSE] and progastrin-releasing peptide [ProGRP]). Optimization of the on-line molecularly imprinted solid-phase extraction (MISPE) protocol ensured that the MIPs had the necessary affinity and selectivity towards their respective signature peptide targets - NLLGLIEAK (ProGRP) and ELPLYR (NSE) - in serum. Two duplex formats were evaluated: a physical mix-ture of the two MIPs (1:1 w/w ratio) inside a single trap column, and two separate MIP trap columns connected in series. Both duplex formats enabled the extraction of the peptides from serum. However, the trap columns in series gave superior extraction efficiency (85.8 +/- 3.8% and 49.1 +/- 6.7% for NLLGLIEAK and ELPLYR, respectively). The optimized protocol showed satisfactory intraday (RSD <23.4 %) and interday (RSD <14.6%) precision. Duplex analysis of NSE and ProGRP spiked into digested human serum was linear (R-2 >= 0.98) over the disease range (0.3-30 nM). The estimated limit of detection (LOD) and limit of quan-tification (LOQ) were 0.11 nM and 0.37 nM, respectively, for NSE, and 0.06 nM and 0.2 nM, respectively, for ProGRP. Both biomarkers were determined at clinically relevant levels. To the best of our knowledge, the present work is the first report of an automated MIP duplex biomarker analysis. It represents a proof of concept for clinically viable duplex analysis of low abundant biomarkers present in human serum or other biofluids. (C) 2021 The Author(s). Published by Elsevier B.V.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] A rapid determination of acidic pharmaceuticals in environmental waters by molecularly imprinted solid-phase extraction coupled to tandem mass spectrometry without chromatography
    Gilart, Nuria
    Marce, Rosa Maria
    Fontanals, Nuria
    Borrull, Francesc
    TALANTA, 2013, 110 : 196 - 201
  • [42] On-line detection of hippuric acid by microextraction with a molecularly-imprinted polysulfone membrane sorbent and liquid chromatography-tandem mass spectrometry
    Moein, Mohammad Mahdi
    El-Beqqali, Aziza
    Javanbakht, Mehran
    Karimi, Mohammad
    Akbari-adergani, Behrouz
    Abdel-Rehim, Mohamed
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1372 : 55 - 62
  • [43] Selective solid-phase extraction using molecularly imprinted polymers for analysis of venlafaxine, O-desmethylvenlafaxine, and N-desmethylvenlafaxine in plasma samples by liquid chromatography-tandem mass spectrometry
    Miranda, Luis Felippe C.
    Domingues, Diego S.
    Queiroz, Maria Eugenia C.
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1458 : 46 - 53
  • [44] Determination of nine bisphenols in sewage and sludge using dummy molecularly imprinted solid-phase extraction coupled with liquid chromatography tandem mass spectrometry
    Sun, Xiaoli
    Peng, Junyu
    Wang, Muhua
    Wang, Jincheng
    Tang, Chunlan
    Yang, Luoxing
    Lei, Hua
    Li, Fang
    Wang, Xueli
    Chen, Jiping
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1552 : 10 - 16
  • [45] Determination of imidacloprid in rice by molecularly imprinted-matrix solid-phase dispersion with liquid chromatography tandem mass spectrometry
    Chen, Ligang
    Li, Bin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 897 : 32 - 36
  • [46] A rapid solid-phase extraction combined with liquid chromatography-tandem mass spectrometry for simultaneous screening of multiple allergens in chocolates
    Gu, Shuqing
    Chen, Niannian
    Zhou, Yao
    Zhao, Chaomin
    Zhan, Lina
    Qu, Li
    Cao, Chen
    Han, Li
    Deng, Xiaojun
    Ding, Tao
    Song, Chang
    Ding, Yaping
    FOOD CONTROL, 2018, 84 : 89 - 96
  • [47] Simple and quick determination of analgesics and other contaminants of emerging concern in environmental waters by on-line solid phase extraction coupled to liquid chromatography-tandem mass spectrometry
    Ferrer-Aguirre, Alejandra
    Romero-Gonzalez, Roberto
    Martinez Vidal, J. L.
    Garrido Frenich, Antonia
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1446 : 27 - 33
  • [48] On-line solid-phase extraction method for determination of triazine herbicides and degradation products in seawater by ultra-pressure liquid chromatography-tandem mass spectrometry
    Rodriguez-Gonzalez, N.
    Beceiro-Gonzalez, E.
    Gonzalez-Castro, M. J.
    Alpendurada, M. F.
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1470 : 33 - 41
  • [49] Analysis of alternariol and alternariol monomethyl ether in foodstuffs by molecularly imprinted solid-phase extraction and ultra-high-performance liquid chromatography tandem mass spectrometry
    Rico-Yuste, A.
    Walravens, J.
    Urraca, J. L.
    Abou-Hany, R. A. G.
    Descalzo, A. B.
    Orellana, G.
    Rychlik, M.
    De Saeger, S.
    Moreno-Bondi, M. C.
    FOOD CHEMISTRY, 2018, 243 : 357 - 364
  • [50] Determination of 74 new psychoactive substances in serum using automated in-line solid-phase extraction-liquid chromatography-tandem mass spectrometry
    Lehmann, Sabrina
    Kieliba, Tobias
    Beike, Justus
    Thevis, Mario
    Mercer-Chalmers-Bender, Katja
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1064 : 124 - 138