On-line duplex molecularly imprinted solid-phase extraction for analysis of low-abundant biomarkers in human serum by liquid chromatography-tandem mass spectrometry

被引:12
|
作者
McKitterick, Nicholas [1 ]
Bicak, Tugrul Cem [2 ]
Switnicka-Plak, A. Magdalena [2 ]
Cormack, A. G. Peter [2 ]
Reubsaet, Leon [1 ]
Halvorsen, Trine Gronhaug [1 ]
机构
[1] Univ Oslo, Sect Pharmaceut Chem, Dept Pharm, POB 1068 Blindern, N-0316 Oslo, Norway
[2] Univ Strathclyde, Dept Pure & Appl Chem, WestCHEM, Thomas Graham Bldg,295 Cathedral St, Glasgow G1 1XL, Lanark, Scotland
基金
欧盟地平线“2020”;
关键词
On-line SPE; Multiplexing; Molecularly imprinted polymers; LC-MS/MS; Low-abundant biomarkers; Targeted bottom-up proteomics; NEURON-SPECIFIC ENOLASE; POLYMERS; LUNG; QUANTIFICATION; SAMPLES; IMMUNOCAPTURE; DIGESTION; ENRICHMENT; ANTIBODIES; PROTEINS;
D O I
10.1016/j.chroma.2021.462490
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the present work, a pair of molecularly imprinted polymers (MIPs) targeting distinct peptide targets were packed into trap columns and combined for automated duplex analysis of two low abundant small cell lung cancer biomarkers (neuron-specific enolase [NSE] and progastrin-releasing peptide [ProGRP]). Optimization of the on-line molecularly imprinted solid-phase extraction (MISPE) protocol ensured that the MIPs had the necessary affinity and selectivity towards their respective signature peptide targets - NLLGLIEAK (ProGRP) and ELPLYR (NSE) - in serum. Two duplex formats were evaluated: a physical mix-ture of the two MIPs (1:1 w/w ratio) inside a single trap column, and two separate MIP trap columns connected in series. Both duplex formats enabled the extraction of the peptides from serum. However, the trap columns in series gave superior extraction efficiency (85.8 +/- 3.8% and 49.1 +/- 6.7% for NLLGLIEAK and ELPLYR, respectively). The optimized protocol showed satisfactory intraday (RSD <23.4 %) and interday (RSD <14.6%) precision. Duplex analysis of NSE and ProGRP spiked into digested human serum was linear (R-2 >= 0.98) over the disease range (0.3-30 nM). The estimated limit of detection (LOD) and limit of quan-tification (LOQ) were 0.11 nM and 0.37 nM, respectively, for NSE, and 0.06 nM and 0.2 nM, respectively, for ProGRP. Both biomarkers were determined at clinically relevant levels. To the best of our knowledge, the present work is the first report of an automated MIP duplex biomarker analysis. It represents a proof of concept for clinically viable duplex analysis of low abundant biomarkers present in human serum or other biofluids. (C) 2021 The Author(s). Published by Elsevier B.V.
引用
收藏
页数:10
相关论文
共 50 条
  • [11] On-line coupling of solid-phase extraction to liquid chromatography-tandem mass spectrometry for the determination of macrolide antibiotics in environmental water
    Ding, Jie
    Ren, Nanqi
    Chen, Ligang
    Ding, Lan
    ANALYTICA CHIMICA ACTA, 2009, 634 (02) : 215 - 221
  • [12] Quantitative determination and confirmatory analysis of N-acetylneuraminic and N-glycolylneuraminic acids in serum and urine by solid-phase extraction on-line coupled to liquid chromatography-tandem mass spectrometry
    Priego-Capote, F.
    Orozco-Solano, M. I.
    Calderon-Santiago, M.
    Luque de Castro, M. D.
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1346 : 88 - 96
  • [13] On-line solid-phase extraction coupled to liquid chromatography tandem mass spectrometry for the analysis of cyanotoxins in algal blooms
    Fayad, Paul B.
    Roy-Lachapelle, Audrey
    Duy, Sung Vo
    Prevost, Michele
    Sauve, Sebastien
    TOXICON, 2015, 108 : 167 - 175
  • [14] ON-LINE SOLID PHASE EXTRACTION COUPLED WITH LIQUID CHROMATOGRAPHY TANDEM MASS SPECTROMETRY FOR THE DETERMINATION OF CODEINE IN HUMAN PLASMA
    Cruz, Alessandro de C.
    Suenaga, Eunice M.
    Abib, Eduardo
    Pedrazzoli, Jose
    QUIMICA NOVA, 2017, 40 (01): : 25 - 29
  • [15] Targeted lipidomics profiling of acute arsenic exposure in mice serum by on-line solid-phase extraction stable-isotope dilution liquid chromatography-tandem mass spectrometry
    Chen, Chao-Yu
    Lin, Pinpin
    Tsai, Ming-Hsien
    Lee, Hui-Ling
    ARCHIVES OF TOXICOLOGY, 2017, 91 (09) : 3079 - 3091
  • [16] High-throughput on-line solid-phase extraction-liquid chromatography-tandem mass spectrometry method for the simultaneous analysis of 14 antidepressants and their metabolites in plasma
    de Castro, Ana
    Femandez, Maria Del Mar Ramirez
    Laloup, Marleen
    Samyn, Nele
    De Boeck, Gert
    Wood, Michelle
    Maes, Viviane
    Lopez-Rivadulla, Manuel
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1160 (1-2) : 3 - 12
  • [17] Analysis of molluscicide metaldehyde in vegetables by dispersive solid-phase extraction and liquid chromatography-tandem mass spectrometry
    Zhang, H. Y.
    Wang, C.
    Xu, P. J.
    Ma, Y. Q.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2011, 28 (08): : 1034 - 1040
  • [18] Surface molecularly imprinted solid-phase extraction for the determination of vancomycin and norvancomycin in milk by liquid chromatography coupled to tandem mass spectrometry
    Zhou, Hao
    Liu, Rong
    Chen, Qianqian
    Zheng, Xiantong
    Qiu, Jingli
    Ding, Tongyan
    He, Limin
    FOOD CHEMISTRY, 2022, 369
  • [19] A fast method for analysing six perfluoroalkyl substances in human serum by solid-phase extraction on-line coupled to liquid chromatography tandem mass spectrometry
    Bartolome, Monica
    Gallego-Pico, Alejandrina
    Huetos, Olga
    Angel Lucena, Miguel
    Castano, Argelia
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (08) : 2159 - 2170
  • [20] Determination of pharmaceuticals in wastewaters using solid-phase extraction-liquid chromatography-tandem mass spectrometry
    Gilart, Nuria
    Maria Marce, Rosa
    Borrull, Francesc
    Fontanals, Nuria
    JOURNAL OF SEPARATION SCIENCE, 2012, 35 (07) : 875 - 882