On-line duplex molecularly imprinted solid-phase extraction for analysis of low-abundant biomarkers in human serum by liquid chromatography-tandem mass spectrometry

被引:12
|
作者
McKitterick, Nicholas [1 ]
Bicak, Tugrul Cem [2 ]
Switnicka-Plak, A. Magdalena [2 ]
Cormack, A. G. Peter [2 ]
Reubsaet, Leon [1 ]
Halvorsen, Trine Gronhaug [1 ]
机构
[1] Univ Oslo, Sect Pharmaceut Chem, Dept Pharm, POB 1068 Blindern, N-0316 Oslo, Norway
[2] Univ Strathclyde, Dept Pure & Appl Chem, WestCHEM, Thomas Graham Bldg,295 Cathedral St, Glasgow G1 1XL, Lanark, Scotland
基金
欧盟地平线“2020”;
关键词
On-line SPE; Multiplexing; Molecularly imprinted polymers; LC-MS/MS; Low-abundant biomarkers; Targeted bottom-up proteomics; NEURON-SPECIFIC ENOLASE; POLYMERS; LUNG; QUANTIFICATION; SAMPLES; IMMUNOCAPTURE; DIGESTION; ENRICHMENT; ANTIBODIES; PROTEINS;
D O I
10.1016/j.chroma.2021.462490
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the present work, a pair of molecularly imprinted polymers (MIPs) targeting distinct peptide targets were packed into trap columns and combined for automated duplex analysis of two low abundant small cell lung cancer biomarkers (neuron-specific enolase [NSE] and progastrin-releasing peptide [ProGRP]). Optimization of the on-line molecularly imprinted solid-phase extraction (MISPE) protocol ensured that the MIPs had the necessary affinity and selectivity towards their respective signature peptide targets - NLLGLIEAK (ProGRP) and ELPLYR (NSE) - in serum. Two duplex formats were evaluated: a physical mix-ture of the two MIPs (1:1 w/w ratio) inside a single trap column, and two separate MIP trap columns connected in series. Both duplex formats enabled the extraction of the peptides from serum. However, the trap columns in series gave superior extraction efficiency (85.8 +/- 3.8% and 49.1 +/- 6.7% for NLLGLIEAK and ELPLYR, respectively). The optimized protocol showed satisfactory intraday (RSD <23.4 %) and interday (RSD <14.6%) precision. Duplex analysis of NSE and ProGRP spiked into digested human serum was linear (R-2 >= 0.98) over the disease range (0.3-30 nM). The estimated limit of detection (LOD) and limit of quan-tification (LOQ) were 0.11 nM and 0.37 nM, respectively, for NSE, and 0.06 nM and 0.2 nM, respectively, for ProGRP. Both biomarkers were determined at clinically relevant levels. To the best of our knowledge, the present work is the first report of an automated MIP duplex biomarker analysis. It represents a proof of concept for clinically viable duplex analysis of low abundant biomarkers present in human serum or other biofluids. (C) 2021 The Author(s). Published by Elsevier B.V.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Analysis of urinary aristolactams by on-line solid-phase extraction coupled with liquid chromatography-tandem mass spectrometry
    Chiang, Su-Yin
    Shih, Wei-Chung
    Liao, Ho-Tang
    Shu, Po-Chi
    Wey, Ming-Tsai
    Huang, Hei-Feng
    Wu, Kuen-Yuh
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (25): : 2494 - 2500
  • [2] Validation of an on-line solid-phase extraction method coupled to liquid chromatography-tandem mass spectrometry detection for the determination of Indacaterol in human serum
    Emotte, Corinne
    Heudi, Olivier
    Deglave, Fanny
    Bonvie, Adrien
    Masson, Laurence
    Picard, Franck
    Chaturvedi, Animesh
    Majumdar, Tapan
    Agarwal, Ashish
    Woessner, Ralph
    Kretz, Olivier
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 895 : 1 - 9
  • [3] Molecularly imprinted solid-phase extraction for the determination of ten macrolide drugs residues in animal muscles by liquid chromatography-tandem mass spectrometry
    Song, Xuqin
    Zhou, Tong
    Liu, Qingying
    Zhang, Meiyu
    Meng, Chenying
    Li, Jiufeng
    He, Limin
    FOOD CHEMISTRY, 2016, 208 : 169 - 176
  • [4] Quantitative determination of risperidone, paliperidone and olanzapine in human serum by liquid chromatography-tandem mass spectrometry coupled with on-line solid-phase extraction
    Ruan, Can-Jun
    Guo, Wei
    Zhou, Miao
    Guo, Gui-Xin
    Wang, Chuan-Yue
    Li, Wen-Biao
    de Leon, Jose
    BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (07)
  • [5] High-throughput analysis of testosterone in serum samples by on-line solid phase extraction liquid chromatography-tandem mass spectrometry
    Savolainen, Kari
    Kiimamaa, Raisa
    Halonen, Toivo
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 (11) : 1845 - 1848
  • [6] Analysis of ketamine and norketamine in hair samples using molecularly imprinted solid-phase extraction (MISPE) and liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Harun, Norlida
    Anderson, Robert A.
    Cormack, Peter A. G.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (07) : 2449 - 2459
  • [7] Determination of Ten Macrolide Drugs in Environmental Water Using Molecularly Imprinted Solid-Phase Extraction Coupled with Liquid Chromatography-Tandem Mass Spectrometry
    Song, Xuqin
    Zhou, Tong
    Li, Jiufeng
    Zhang, Meiyu
    Xie, Jingmeng
    He, Limin
    MOLECULES, 2018, 23 (05):
  • [8] Method of Glyphosate, AMPA, and Glufosinate Ammonium Determination in Beebread by Liquid Chromatography-Tandem Mass Spectrometry after Molecularly Imprinted Solid-Phase Extraction
    Malysiak, Marta
    Kiljanek, Tomasz
    MOLECULES, 2022, 27 (17):
  • [9] A dummy molecularly imprinted solid-phase extraction coupled with liquid chromatography-tandem mass spectrometry for selective determination of four pyridine carboxylic acid herbicides in milk
    Tan, Sijia
    Yu, Hailong
    He, Yahui
    Wang, Miao
    Liu, Guiqiao
    Hong, Sihui
    Yan, Feiyan
    Wang, Yanli
    Wang, MengQiang
    Li, Tengfei
    Wang, Jing
    Abd El-Aty, A. M.
    Haclmuftuoglu, Ahmet
    She, Yongxin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1108 : 65 - 72
  • [10] On-line solid-phase extraction high-performance liquid chromatography-tandem mass spectrometry for the quantitative analysis of tacrolimus in whole blood hemolyzate
    Neu, Volker
    Delmotte, Nathanael
    Kobold, Uwe
    Duelffer, Thomas
    Herrmann, Rupert
    von der Eltz, Herbert
    Huber, Christian G.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 404 (03) : 863 - 874