Forced expiratory volume in 1 second (FEV1) and forced vital capacity (FVC) variability in asymptomatic never-smoking men

被引:13
|
作者
Humerfelt, S
Eide, GE
Kvåle, G
Gulsvik, A
机构
[1] Univ Bergen, Dept Thorac Med, N-5020 Bergen, Norway
[2] Univ Bergen, Dept Epidemiol, N-5020 Bergen, Norway
来源
CLINICAL PHYSIOLOGY | 1998年 / 18卷 / 04期
关键词
community survey; spirometric recordings; within- and between-subject variability;
D O I
10.1046/j.1365-2281.1998.00115.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
We examined the effects from subjects, technicians and spirometers on within-session variability in successful recordings of forced expiratory volume in 1 second (FEV1) and forced vital capacity (FVC) in 4989 asymptomatic never-smoking men. All eligible men aged 30-46 years living in western Norway (n = 45 380) were invited to a cross-sectional community survey. Information on respiratory symptoms, smoking habits and occupational exposures was obtained from a self-administered questionnaire. Three successful FEV1 and FVC recordings were obtained in 26 368 attendants using three dry-wedge bellow spirometers operated by 10 different technicians. Within-subject standard deviation (SD) from three recordings of FEV1 and FVC was on average 102 and 106 ml, respectively, and increased with height (14 and 17 ml, respectively, per 10 cm) and body mass index (BMI) (11 and 14 ml, respectively, per 5 kg m(-2)). Between-subject SD of the mean of three FEV1 and FVC recordings was 591 and 754 ml, respectively, and increased in groups of increasing height (43 and 40 ml, respectively, per 10 cm). Small, but significant, differences were observed between technicians in within-subject SD and in levels of FEV1 and FVC. Homogeneity of between-subject variability, necessary for linear regression analysis, was obtained using FEV1 and FVC divided by height squared. In conclusion, within-subject variability in three successful spirometric recordings was small, but dependent on height and BMI of the subjects as well as technician performance. The observed heterogeneity in between-subject variation in FEV1 and FVC levels disappeared when each variable was divided by height squared. Novel multiple linear regression equations for FEV1/height(2) and FVC/height(2) were developed to be used in evaluating the effects from occupational airborne exposures in Nordic men aged 30-46 years.
引用
收藏
页码:387 / 396
页数:10
相关论文
共 50 条
  • [1] Determinants of forced expiratory volume in 1 second (FEV1), forced vital capacity (FVC), and FEV1/FVC in chronic spinal cord injury
    Jain, Nitin B.
    Brown, Robert
    Tun, Carlos G.
    Gagnon, David
    Garshick, Eric
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2006, 87 (10): : 1327 - 1333
  • [2] Forced expiratory volume in 1 second/forced expiratory volume in 6 seconds (FEV1/FEV6) is a suboptimal surrogate for FEV1/forced vital capacity (FEV1/FVC) in the spirometric diagnosis of airflow obstruction in a diverse urban population
    Fukunaga, M
    Kim, EJ
    Sundaram, SC
    Sullivan, J
    Friedmann, P
    Salzman, SH
    CHEST, 2005, 128 (04) : 172S - 172S
  • [3] ADJUSTING THE ONE-SECOND FORCED EXPIRATORY VOLUME (FEV1) TO REDUCE VARIANCE OF FEV1-VITAL CAPACITY
    HANSEN, JE
    SUE, DY
    FEDERATION PROCEEDINGS, 1980, 39 (03) : 1167 - 1167
  • [4] How to interpret reduced forced expiratory volume in 1 s (FEV1)/vital capacity ratio with normal FEV1
    Barisione, G.
    Crimi, E.
    Bartolini, S.
    Saporiti, R.
    Copello, F.
    Pellegrino, R.
    Brusasco, V.
    EUROPEAN RESPIRATORY JOURNAL, 2009, 33 (06) : 1396 - 1402
  • [5] Reversibility of forced expiratory volume in 1 second (FEV1) by albuterol
    Pisarik, Paul
    FAMILY MEDICINE, 2006, 38 (07) : 463 - 464
  • [6] Forced expiratory volume in 6 s (FEV6 ) and FEV1 /FEV6 values as a viable alternative for forced vital capacity (FVC) and FEV1 /FVC values during pregnancy in South East Nigeria: A preliminary study
    Nwagha, U.
    Iyare, E.
    Anyaehie, U.
    Onyedum, C.
    Okereke, C.
    Ajuzieogu, O.
    Amucheazi, A.
    Oluboboku, T.
    Agu, P.
    Igweh, J.
    Oguanuo, T.
    ANNALS OF MEDICAL AND HEALTH SCIENCES RESEARCH, 2014, 4 (04) : 516 - 521
  • [7] Variation in "normal values" of forced vital capacity (FVC) and ratio of one-second Forced Expiratory Volume (FEV1)/FVC between 42 Burden of Obstructive Lung Disease (BOLD) sites
    Burney, Peter
    Patel, Jaymini
    EUROPEAN RESPIRATORY JOURNAL, 2019, 54
  • [8] Bronchial asthma with normal forced expiratory volume in 1 second (FEV1) compared with low FEV1
    Ohwada, Akihiko
    Kitaoka, Hiroko
    JOURNAL OF THORACIC DISEASE, 2024, 16 (09) : 5580 - 5590
  • [9] Expiratory and inspiratory forced vital capacity and one-second forced volume in asymptomatic never-smokers in Norway
    Gulsvik, A
    Tosteson, T
    Bakke, P
    Humerfelt, S
    Weiss, ST
    Speizer, FE
    CLINICAL PHYSIOLOGY, 2001, 21 (06): : 648 - 660
  • [10] Forced expiratory flow between 25% and 75% of vital capacity and FEV1/forced vital capacity ratio in relation to clinical and physiological parameters in asthmatic children with normal FEV1 values
    Simon, Michael R.
    Chinchilli, Vernon M.
    Phillips, Brenda R.
    Sorkness, Christine A.
    Lemanske, Robert F., Jr.
    Szefler, Stanley J.
    Taussig, Lynn
    Bacharier, Leonard B.
    Morgan, Wayne
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2010, 126 (03) : 527 - U217